Precautions for long-term idle use of Delta inverter

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:

                              Precautions for long-term idle use of Delta inverter

1. After the equipment is energized, the inverter will blow up the machine and the pre-circuit breaker will jump off.

2. After starting, the inverter panel is not displayed

3. The inverter runs normally after starting, but it fails after operation

4. The inverter runs normally after starting, but it appears to be a frying machine after operation

Why is there a phenomenon of inverter failure described above?

1. The improper placement environment of the inverter will lead to the above problems.

2. The inverter is composed of rectifier module, IGBT and electrolytic capacitor and other primary components, during which if the electrolytic capacitor is not energized for a long time, it will cause the electrolyte in the electrolytic capacitor to dry up, so that the capacity decreases and the leakage increases. In this way, when the inverter is powered, the switching power supply operation will be abnormal or damaged, and in serious cases, this will lead to the electrolytic capacitor of the main circuit being damaged, resulting in the explosion of the inverter.

Why do some inverters still work normally after being placed for a period of time?

1. The inverter storage environment is good

2. The inverter has not been working for a long time under overheat or overload conditions

3. The service life of the inverter is short

4. The capacitance characteristics inside the inverter are better than **

How to prevent the inverter from powering failure?

1. If the inverter is not used for a long time, it should be sealed and stored in a dust-proof and moisture-proof environment, and the storage temperature is -25C-65C.

2. It is safer and more useful to use special equipment to charge the inverter regularly (once every 3 months) and check the input and output ports. 220 volts are supplied to a 380 volt inverter (110 volts are supplied to a 220 volt inverter) and the voltage slowly rises from 0 volts to 220 volts. The duration is determined according to the power of the inverter. Then, supply 380 volts (220 volts) to the drive and look at the input voltage. Only an imbalance of +/- 3% was promised.

More on that
The principle of Delta's inverter inverter The principle of Delta's inverter inverter

As far as I know, since the advent of active induction motors, there has been a variable frequency operation in the way of communicating generators. Change the rotational speed of the generator, and change its output frequency. Before the advent of high-speed transistors, this was one of the main ways to change the speed of the motor, but due to the decrease in the speed of the generator ...

Identify the problem area of the inverter - Delta Identify the problem area of the inverter - Delta

In the process of inverter protection and maintenance, various problems are often encountered, such as field line problems, poor primary parameter settings or mechanical equipment shortcomings. If there is a defect in the inverter, how to distinguish which part of the problem is a little more detailed here. ...

Delta-B series inverter inverter output module is damaged and the drive circuit is damaged Delta-B series inverter inverter output module is damaged and the drive circuit is damaged

Delta-B series inverter inverter output module is damaged and the drive circuit is seriously damaged: the drive integrated circuit T250V or burst, or the output terminal and the power supply ground are short-circuited, the filter capacitor is sprayed, the regulator tube is broken down or open, the resistance is open or the resistance value increases, and the circuit board carbonization is damaged.

The cause of the damage of the inverter - Delta inverter The cause of the damage of the inverter - Delta inverter

First, the heat dissipation of the inverter is not good In fact, we all know that too high a temperature has a damaging effect on any equipment, just like a human brain, too high a temperature will also burn out the brain, in fact, the same is true for inverters. When the temperature rises, because of the sensitivity of semiconductors to temperature, the inverter ...

Precautions for summer maintenance and maintenance of inverters - Delta Precautions for summer maintenance and maintenance of inverters - Delta

1. Check the operating status of the inverter, whether the voltage and current value during operation are within the normal range. 2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature is generally between -10 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C. 3. Avoid ...

Solution to the problem of inverter undervoltage - Delta Solution to the problem of inverter undervoltage - Delta

In order to protect the inverter, when the bus voltage is too low, the inverter will report the undervoltage problem and close the pulse output of the inverter. This is an important and necessary way to protect the inverter equipment from damage. This issue also cannot be blocked. ...

Introduction to the internal components of the inverter - Delta inverter Introduction to the internal components of the inverter - Delta inverter

Rectifier circuits It consists of six rectifier diodes from VD1 to VD6 to form an uncontrollable full-wave rectifier bridge. Regarding the rated power supply of 380V, the reverse withstand voltage value of the diode should be 1200V, and the forward current of the diode is 1.414-2 times of the rated current of the motor. ...

Delta servo system composition Delta servo system composition

The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment. (1) Servo motor Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.

Precautions for Delta's DPA pressure sensor Precautions for Delta's DPA pressure sensor

1. When the device is installed, leave the place with high voltage and strong high-frequency noise to prevent disturbance. Prevent use in places where the following conditions occur: (a) Excessive dust and corrosive gases; (b) high humidity and very high radiation; (c) ...

The cause of short circuit in power transformer - Delta The cause of short circuit in power transformer - Delta

Power transformers are used very frequently in daily livelihoods, in order to ensure the normal use of electricity, the safety and stability of the power transformer is the key point, once the transformer has a problem of prevention, it is necessary to quickly find out the cause and deal with it, take the transformer short circuit as an example, the damage caused by the insufficient treatment is ...

Delta's PLC programmable controller product list Delta's PLC programmable controller product list

1. Programmable manipulator AH series Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a comprehensive modular design, and on the basis of Delta's research and development skills, it has developed ...

How to use Delta's inverter operation How to use Delta's inverter operation

(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.

Introduction to Constant Power and Constant Torque in Frequency Conversion Speed Regulation - Delta Introduction to Constant Power and Constant Torque in Frequency Conversion Speed Regulation - Delta

In general, factory motors are based on the additional speed values obtained at a given power frequency voltage (380 V, 50 Hz). If 380V is not reached under actual operating conditions, e.g. as long as 300V, 50 Hz, the voltage is significantly undervoltaged. Fundamentally, it cannot reach the extra rev value, due to the ...

How to choose the right Delta inverter for the motor How to choose the right Delta inverter for the motor

Delta's inverter has made the motor drive system complete two hopes: first, the motor has completed the operation of higher power; The second is to make the motor controllable and prevent the problem of the big cow pulling the trolley. But the problem in front of the engineer is: there are so many types of motor loads, and the frequency converter ...

Servo motor speed improvement method - Delta Servo motor speed improvement method - Delta

When many engineers debug servo motors, they often have such a problem: why is my servo motor so slow, how can I improve the speed, and how much can the maximum speed reach? The basis for the confirmation of the speed method of the servo motor: the speed of the servo motor. ...

Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines

In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, and completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development in the pharmaceutical industry.

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

Delta's soft starter component role Delta's soft starter component role

The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc. ...

Delta's method of reducing the number of inverter repairs Delta's method of reducing the number of inverter repairs

Inverter is a modern factory in the use of a very ubiquitous equipment, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

Delta unveiled the ASDA-A2 series of AC servo motors and drives Delta unveiled the ASDA-A2 series of AC servo motors and drives

New Delhi, September 2, 2010 – Delta Group, the world's largest supplier of switching power supplies and brushless DC fans, is committed to innovation, energy efficiency and environmental protection, and has launched a new and advanced high-performance ASDA-A2 series of servo motors and servo drives for motion control and networking in India.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top