(1) Ambient temperature:

The inverter is the same as other electronic equipment, and has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is very easy to be affected by the operating temperature, but in order to ensure the safety and reliability of the inverter, it should be considered to leave room for use, and it is best to control it below 40 °C; Derating between 40 and 50°C, the rated output current must be reduced by 1% for every 1°C increase. If the ambient temperature is too high and the temperature changes greatly, the insulation of the inverter will be greatly reduced, which will affect the life of the inverter.

                               Precautions for the installation environment of the inverter - Delta inverter

(2) Ambient humidity:

The relative humidity of the surrounding air of the inverter is ≤ 95% (no condensation), and desiccant and heater must be added to the inverter cabinet if necessary according to the on-site operating environment.

(3) Oscillation and shock:

In the process of operation, attention should be paid to prevent oscillation and impact. As we know, the inverter is assembled by welding, screw connection, etc. When the inverter or the control cabinet equipped with the inverter is subjected to mechanical oscillation or impact, it will cause solder joints, screws and other connecting equipment or connectors to loosen or fall, causing poor electrical contact and even causing serious problems such as short circuit during the period. Therefore, in addition to improving the mechanical strength of the control cabinet and keeping away from the oscillation source and impact source, the inverter should also install a shock-resistant rubber gasket outside the control cabinet, and a buffer rubber pad should be installed between the equipment and the device plate in the control cabinet to absorb the shock. Generally, after a period of operation of the equipment, the control cabinet should be inspected and maintained.

(4) Electrical Environment:

Protection against electromagnetic interference

The electrical body of the inverter is the hardware and software circuit of the power module and its control system, and when these components and software programs are subjected to certain electromagnetic interference, the hardware circuit will fail, and the software program will fly wildly. Therefore, in order to prevent electromagnetic interference, the inverter should have a way to prevent electromagnetic interference according to the electrical environment in which it is located. For example, the input power line, output motor line, and control line should be far away; Vulnerable equipment and signal lines should be kept away from the inverter device as much as possible; Shielded cables should be used for critical signal lines, and it is recommended that the shielding layer be grounded by 360° grounding method.

Protection against overvoltage at the input:

The main circuit of the inverter is composed of power electronic equipment, which is very sensitive to overvoltage, and the overvoltage at the input of the inverter will cause permanent damage to the main components. For example, some factories have their own generators for power supply, and the power grid will fluctuate greatly, so there should be precautions against overvoltage at the input end of the inverter.

(5) Altitude:

The inverter device can output the rated power at an altitude of less than 1000m. However, at altitudes above 1000m, its output power decreases. As shown in Figure 1 for the comparison between the altitude and the output current of the inverter device address, it can be seen that the altitude exceeds 1000m, and the output current of the inverter is reduced, and the output current is 40% when the altitude is 4000m, and the output current is 1000m.

More on that
A brief description of the selection of Delta inverters A brief description of the selection of Delta inverters

Delta's inverter series are as follows: 1:VFD-EL,VFD-S,VFD-L,VFD-C200 Voltage 220V, 380V, power scale 100W-7.5kw The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fan pumps, food and medical ...

Delta UPS uninterruptible power supply R-2K series Delta UPS uninterruptible power supply R-2K series

With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.

Delta's inverter adjusts the motor speed mode Delta's inverter adjusts the motor speed mode

The speed control on Delta's inverter is mainly as follows: 1. Adjust the variable resistance directly from the surface of the Delta inverter 2. External analogue voltage or current signal to adjust 3. Take advantage of the multi-function of the inverter ...

PLC control belt conveyor soft start method - Delta PLC control belt conveyor soft start method - Delta

Belt conveyor is a kind of continuous conveyor, which is one of the most important types of stationary or escorted cranes. The belt conveyor is the use of friction to convey the dynamics, with belts, steel belts, steel fiber belts and chemical fiber belts as a kind of adaptation to the transmission of materials and traction operations.

Delta successfully held a seminar on new technologies for electronic power Delta successfully held a seminar on new technologies for electronic power

From May 23 to 25, 2019, the Delta Power Electronics Technology Application Seminar, hosted by Delta Group of Zhejiang University, was held at the KONE Hotel in Wujiang, Jiangsu. Experts and professors from the power electronics technology industry from all over the world and 360 teachers, students and practitioners from more than 10 key universities such as Tsinghua University and Zhejiang University.

Pulse control wiring method for Delta servo drives Pulse control wiring method for Delta servo drives

Parameter settings P1-XX are the basic parameters P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX P1-01 Control form selection, pick ...

Delta has always been the shipment champion in Taiwan's inverter market Delta has always been the shipment champion in Taiwan's inverter market

Based on trend forces, the sales market of solar power generation in Taiwan was analyzed. In the first half of 2019, AUO ranked second, while third-ranked Canada Solar entered the top three for the first time. Compared with the previous year, the sales market in Taiwan, China in the first half of 2019 was in the total delivery of common decoration ...

The reason for the low voltage trip of the inverter - Delta The reason for the low voltage trip of the inverter - Delta

The low voltage of the inverter mainly refers to the low voltage of the central DC circuit, and the reasons for the low voltage of the central DC circuit generally come from two aspects: ​ (1) Low voltage from the input side of the power supply The power supply under normal conditions ...

Solution to Delta's overload trip fault Solution to Delta's overload trip fault

1. The main reason for VFD overload (1) Mechanical overload. The main characteristic of overload is the heating of the motor, which can be detected by reading the operating current on the display. (2) The three-phase voltage imbalance leads to excessive running current in a certain phase, resulting in overload tripping. It is characterized by uneven heating of the motor ...

The parameter that needs to be set for the inverter - Delta The parameter that needs to be set for the inverter - Delta

There will be some difference between the parameter setting of the inverter at the factory and the requirements of practical application. Therefore, the reasonable setting of the inverter parameters is directly related to whether the inverter can be used normally, which is of decisive significance. General-purpose inverters generally have dozens or even hundreds of functional parameters.

Precautions for the use of Delta inverter MS300 series Precautions for the use of Delta inverter MS300 series

Before operating the MS300 series products, please read and pay attention to the relevant safety information to ensure your own safety and product safety. When operating the wiring and installing the inverter, it is necessary to confirm that the power supply is closed. After blocking the communication power supply, the inverter POWER indicator (located in ...

EMC Filter Installation Considerations – Delta EMC Filter Installation Considerations – Delta

All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...

Inverter technology is a motor control method – Delta Inverter technology is a motor control method – Delta

When you are using the motor, if you simply change the frequency, your motor will most likely be burned out. This problem is especially acute when the frequency is reduced. In order to prevent the motor from burning out, the inverter must change the voltage at the same time as the frequency. ...

Delta's inverter is automatically changed to manual setting Delta's inverter is automatically changed to manual setting

The converter is capable of manual and active switching: 1. The switching between the manual operating system and the DCS operating system is done by the transfer switch SA installed on the field operation tower, which has active, manual and ...

Delta's inverter and output reactor function Delta's inverter and output reactor function

input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the function and service life of the inverter and the motor, so it is necessary to install a transmission system in front of it.

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud platforms are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

The cause of the failure of the main power supply circuit of the inverter - Delta The cause of the failure of the main power supply circuit of the inverter - Delta

We really talked a lot about the relevant knowledge of inverter repair, but we talked less about the main reasons for protecting the main power supply circuit. Then take a look at the introduction below: When there is a fault in the main power supply circuit of the inverter, in addition to selecting each component to match the corresponding power, it should also ...

Delta's Smart series of micro-modules help transform high-speed tunnel networks Delta's Smart series of micro-modules help transform high-speed tunnel networks

Recently, Delta's Smart series of micro-modular data center processing solutions successfully assisted the smooth implementation of a provincial tunnel network transformation project in a province. The project has set up a series of safety operation networks such as video, lights, signals, networks, rescues, and alarms for the safe operation of key roads in the province.

DC motor speed regulation method - Delta DC motor speed regulation method - Delta

There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation. 1. Armature loop string resistance The applied resistor is connected to the armature circuit.

Precautions for the operation of Delta servo motors Precautions for the operation of Delta servo motors

1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top