Delta's PLC programmable controller product list

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1. Programmable manipulator AH series

                               Delta's PLC programmable controller product list

  Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a fully modular design, develops advanced functions based on Delta's R&D skills, and selects highly integrated software and interfaces to further interpret the automation system. In addition to the abundant function block (FB), cost-effective, multiple expansion functions and other characteristics, together with the excellent system extension and scalability, the AH series has a dedicated motion control CPU, through EtherCAT and other motion control network connection servo drives, can carry out high-speed, high-precision machine control, for high-end application industry and end customers to save construction costs, provide more competitive solutions.
  ​
  2. High-performance multi-purpose controller AS series

  Delta's AS series PLC is a high-performance general-purpose controller designed for automation equipment. Delta's self-developed 32-bit SoC CPU greatly improves performance (40 k steps/ms) and can be expanded to up to 32 modules or up to 1,024 I/O. The powerful positioning control function can support up to 8-axis CANopen motion network / 6-axis 200 kHz pulse control together, which is suitable for equipment in electronic manufacturing, mechanical processing, food packaging, textile equipment and other occupations.

  3. Programmable controller DVP series

  Delta's DVP series programmable controllers are used in various industrial automation machines with the characteristics of high speed, robustness, and high reliability, providing fast performance of logic operations, rich instruction sets, multiple expansion functions, and high cost performance, and supporting a variety of communication standards, effectively connecting Delta's communication motor drives, servos, human-machine interfaces, and temperature control products through industrial networks, providing users with a complete solution with the "Delta Solution".
More on that
Delta's MZM position drive system is used for precise application of large inertia Delta's MZM position drive system is used for precise application of large inertia

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...

Factors affecting Delta's inverter motors and countermeasures Factors affecting Delta's inverter motors and countermeasures

1. The influence of leakage current on the motor and countermeasures If the wiring length is very long, the stray capacitance between the wires will increase, resulting in leakage current. It will initiate overcurrent maintenance, increase leakage current or not ensure the correctness of the current display. The bad situation is that the inverter will ...

The principle of Delta's inverter inverter The principle of Delta's inverter inverter

As far as I know, since the advent of active induction motors, there has been a variable frequency operation in the way of communicating generators. Change the rotational speed of the generator, and change its output frequency. Before the advent of high-speed transistors, this was one of the main ways to change the speed of the motor, but due to the decrease in the speed of the generator ...

Delta's power supply series application considerations Delta's power supply series application considerations

(1) Considering that the power supply is inconsistent at the time of power-on, the load is short-circuited, and the rational load may present a reverse voltage, the output end of each power supply connected in series should be set up with two anti-parallel tubes, and the forward additional current of the two * tubes should not be less than the additional output current of the power supply, and the reverse breakdown voltage should not be less than ...

The output of the inverter is not short-connected to the power frequency The output of the inverter is not short-connected to the power frequency

1. To switch the motor of the power frequency, the parking method is set to free parking, and it is important not to park softly 2. Intercept the contactor of the motor from the output end of the inverter, and the control stop button and the inverter parking button are the same composite button, that is, when the inverter is pressed, the inverter parking will be followed by the contactor line.

Requires an inverter speed control application – Delta Requires an inverter speed control application – Delta

Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...

Selection of braking resistors for Delta inverters Selection of braking resistors for Delta inverters

1. The necessity of braking resistance If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage. Because usually the inverter has a built-in overvoltage maintenance function, the main circuit overvoltage (O...

Set the parameters when reading and uploading the Delta PLC program Set the parameters when reading and uploading the Delta PLC program

Open Delta's programming software, and use WPLSOFT to do the demo here; First, click on the settings and then click on the communication settings in the settings, select the communication mode, communication port, communication baud rate, communication station number, etc. After the setting is finished, click OK to automatically close the pop-up window. In the dish ...

Introduction to the inverter selection strategy - Delta inverter Introduction to the inverter selection strategy - Delta inverter

1. Ability to adapt to the environment 1.1 Ability to adapt to grid voltage fluctuations When the motor on the bus starts in a group, when the largest motor unit on the bus starts, the influence on the operation of the inverter, which is related to the input voltage fluctuation range parameters promised by the inverter.

What are the problems of the inverter if it is not used for a long time - Delta What are the problems of the inverter if it is not used for a long time - Delta

Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...

Delta UPS power supply RT5K extension configuration method for 2 hours Delta UPS power supply RT5K extension configuration method for 2 hours

Engined DC: 1K=36V, 2K=72V, 3K=96V, 5K, 6K, 10K=192V UPS power supply accounting formula: 1KVA (volt-ampere) =700W (watt) =1000VA (volt) UPS power supply x extended time + starting DC = how big the battery is Start DC + V number of battery = how much power is distributed ...

Delta's key steps in inverter maintenance Delta's key steps in inverter maintenance

First, the maintenance of the inverter must first check whether the sound in the operation of the motor has changed abnormally, including, whether the motor is in operation to form a sensation. 2. Check whether the natural environment of the inverter installation has changed. For example, whether the operating temperature is normal. Learn more about Delta's inverter ...

Delta linear motor driver ASDA-A2R series Delta linear motor driver ASDA-A2R series

In view of the rapid transformation of the industry, Delta has specially proposed a total linear motor solution, deploying various communication interfaces, extending the evolved model ASDA-A2R from ASDA-A2 as a linear horse driver, and deploying Delta's high-speed bus controller and axis card to form a complete linear motor ...

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of hundreds of schools of thought, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

The inverter sets the characteristic parameters of the motor The inverter sets the characteristic parameters of the motor

1. Parameters to be set for the motor When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...

Precautions before installation of Delta inverters Precautions before installation of Delta inverters

Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows: 1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...

Post-inverter shutdown maintenance project – Delta Post-inverter shutdown maintenance project – Delta

1. Use a vacuum cleaner with a plastic nozzle to completely clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment. 2. Check the ventilation and lighting of the inverter room, and the ventilation equipment can work normally. 3. Check the inverter ...

Delta has always been the shipment champion in Taiwan's inverter market Delta has always been the shipment champion in Taiwan's inverter market

Based on trend forces, the sales market of solar power generation in Taiwan was analyzed. In the first half of 2019, AUO ranked second, while third-ranked Canada Solar entered the top three for the first time. Compared with the previous year, the sales market in Taiwan, China in the first half of 2019 was in the total delivery of common decoration ...

Delta's powerful NT series industrial-grade UPS Delta's powerful NT series industrial-grade UPS

Delta's NT series industrial-grade UPS has always been an ideal choice for applications that require high power safety due to their high reliability and high-density planning. IGBT high-frequency switching sinusoidal pulse width modulation technology planning, which makes UPS have good power supply quality, high efficiency, low heat loss, noise ...

Analysis of abnormal operation of Delta inverter Analysis of abnormal operation of Delta inverter

There are many setting parameters of the inverter, each parameter has a certain selection range, and the phenomenon that the inverter can not operate normally is often encountered in the application due to the improper setting of a single parameter, so the relevant parameters must be set correctly. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top