Delta was established in 1971 to provide power supply and heat dissipation treatment programs for the world. Over the past 20 years, Delta's development in Chinese mainland has become increasingly deep-rooted, and its business operations cover development, production, sales and service. With innovative skills, continuous strengthening of engineering development equipment and sophisticated testing equipment, Delta continues to introduce efficient, energy-saving, and reliable products and treatment plans.
Delta has a deep history in the development and production of general-purpose inverter products. In response to the needs of domestic customers, Delta has developed two types of inverters. The first is a general standard product, which has a wide range of applications and can comprehensively improve the automation level of customer equipment. The other category is special products for occupations, which are developed for the special processes and needs of occupations.
Delta's inverter product introduction
C2000 Plus/C2000 Series – Universal vector operated frequency converters
The C2000 Plus series has magnetic field vector variable frequency drive technology, supports diversified communication protocols, and has built-in PLC and communication master functions, providing a highly flexible processing planning platform, with a maximum power range of up to 560 kW, providing the best driving ability and stability for various heavy-duty constant torque load applications.
Features:
It is not easy to over-current maintenance, and the output is sufficient - the rated current can support the overload (150% / 60 seconds, 180% / 3 seconds) of overload;
High environmental resistance and robustness – IP55 long-lasting fan, heatsink optimization, reinforced board coating (3C3 rating);
Precise motor control and high modulation - non-sensing vector control of support induction/permanent magnet/synchronous reluctance motors;
Easy integration of planning and flexible operation – built-in PLC (10k steps), integrated remote I/O support CANopen / Modbus communication master setup;
Seamless integration with multiple communication supports – EtherCAT, EtherNet/IP, Modbus TCP, PROFINET, PROFIBUS DP, DeviceNet, CANopen;
The professional functions are complete and excellent - point-to-point position control, master-slave torque distribution, over-excitation energy traction, etc.
VFD-CP2000 series - special vector control inverter for fan and water pump
The CP2000 series is a non-inductive vector-operated inverter, which continues the consistency of Delta's planning team's concept of energy conservation and power saving, and is specially designed for fans, pumps, HVAC Drive-related applications, PID intelligent adjustment, and excellent planning of industrial efficiency.
Features:
Built-in Delta PLC (10K STEPS) logic manipulator, deploying the network system can easily achieve distributed control and independent operation functions, and achieve your future intelligent control imagination.
The function of the perpetual calendar makes it easy for you to plan PLC programs, do timing ON/OFF control, daylight saving time setting and other functions;
Wide range of models, which can meet industrial needs (0.75-400KW);
Modular planning for easy maintenance and expansion;
High-speed communication interface, built-in MODBUS and BACnet protocol (Protocol), and optional ProfiBUS-DP, DeviceNet, MODBUS TCP, EtherNet-IP, CANopen Cards, diversified communication methods;
Long life planning and life testing of important parts;
PCB coating planning for enhanced environmental resistance;
Global safety compliant with CE / UL / cUL;
LCD standard model;
Excellent heat dissipation planning, can operate in a 50°C ambient temperature environment, actively adjust the output rating according to the temperature rise conditions, and keep the inverter from operating;
The fire form is set as an emergency, smoke exhaust, and pressurization is not interrupted;
Multi-pump operation, quantitative and timed cycle control, and can control eight motors at the same time (as shown in Figure 1 and 2, multi-control Relay Card needs to be installed).
MS300 series - compact and standardized vector-operated inverter
It has the advantages of miniaturization, high function, high reliability, and simple installation, and transforms every investment in industrial resources into abundant results. Optimized structure and lock-free screw terminal planning, friendly user interface can easily complete parameter setting, can quickly imitate parameters, and improve production efficiency.
Features:
Support induction motor and permanent magnet motor open-loop control;
Output frequency range 0-599Hz (standard model);
High-frequency 1500Hz output (high-speed model);
Built-in PLC can be programmed (2K steps);
Built-in 33kHz high-speed pulse input terminal x1 (MI7);
Built-in 33kHz high-speed pulse output terminal x1 (DFM);
EMC Filters (Built-in/Optional);
Torque Off (SIL2/PLd)
Full range of built-in brake crystals;
New circuit board coating (IEC 60721-3-3 class 3C2) for enhanced environmental resistance;
5-digit high-brightness LED keypad (can be pulled out to the control panel with E/M/B extension cable);
Supports a variety of communication interfaces: PROFIBUS DP, Modbus TCP, EtherNet/IP, DeviceNet, CANopen.
|
More on that
|
Delta's MZM position drive system is used for precise application of large inertia
Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...
|
|
Precautions for inverter selection - Delta
The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions:
1. The environment is suitable for some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters).
|
|
Ways to reduce the failure rate of Delta drives
If you want to reduce the fault rate of Delta inverter, it is necessary to check it daily, and what are the detailed items?
Delta inverter fault repair ...
|
|
Common problems of VFD control motors - Delta
Question 1. Why use a VFD to control the motor?
Speaking of this question, let's first take a brief look at these two devices. The motor is a rational load, which hinders the change of current, and a large change in current will occur when it is started. VFD, which is actually made up of a rectifier inverter circuit, ...
|
|
Repair of Delta inverter problemsView items
Daily inspection item 1 of Delta's inverter problem repair:
Check whether there is any abnormal change in the sound of the motor during operation, including whether oscillation occurs during the operation of the motor.
Delta's daily inspection of inverter problem repair ...
|
|
Tips and methods for using PLC - Delta PLC
First, the selection of output module
The output modules are divided into transistors, triacs, and contact types:
(1) The switching speed of the transistor type is fast (generally 0.2ms), but the load can be small, about 0.2-0.3A, 24VDC, suitable for fast switching, signal contact...
|
|
Application of Delta A2 servo on packaging twisting machine
Double-end twisting machine is a more traditional sugar block packaging machine, it is widely used in small and medium-sized sugar block production enterprises, with a high degree of automation, which can not only complete the packaging of single or multi-layer paper, but also can package a variety of shapes of hard candy or soft candy.
|
|
Problems in the use of Delta inverters and Delta motors
Delta's motors are the most frequently used rotating things so far, and with the development and spread of Delta inverters, they need to be used in conjunction with inverters.
However, in the process of combining inverters and motors, it is inevitable to encounter a lot of ...
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|
Delta's inverter method to reduce the failure rate
Daily inspection item 1 of Delta's inverter problem repair:
Check whether there are any abnormal changes in the sound of the motor during operation, including whether there is vibration during the operation of the motor.
Routine inspection item 2 of Delta inverter problem repair:
Check out the inverter installation environment is ...
|
|
Troubleshooting of small electromagnetic relay cores - Delta
The main problems of the iron core of the small electromagnetic relay are that the armature cannot be sucked after being electrified:
This may be due to broken coils, foreign matter between the moving and static cores, and low power supply voltage. It should be patched on a case-by-case basis.
When energized, the armature is noisy:
This may be because of the ...
|
|
Detection methods for Delta circuit breakers, AC contactors and frequency converters
1. Circuit breaker
A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked.
Under normal circumstances, when in the ON state, the input input ...
|
|
Delta's inverter speed regulation application site
Inverter is a kind of speed regulating device, where to use the motor speed regulation, especially asynchronous motor speed regulation, will use the inverter, now mainly in industrial equipment has been used on a large scale, because the motor is the heart of the industry, and the three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
Introduction to the common sense of Delta inverter
The low-voltage fuse cannot be used as an overload maintenance for the motor.
It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line.
The additional current of the fuse must be greater than or equal to the additional current of the melt.
...
|
|
Pulse control wiring method for Delta servo drives
Parameter settings
P1-XX are the basic parameters
P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction
P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX
P1-01 Control form selection, pick ...
|
|
Delta's C-series evolution is complete—C2000+ inverter
Those who know more about Delta's automation know that Delta's inverters have two main series: "M300" and "C2000".
"Compact Inverter M300 Series": This series has been introduced many times before, including ...
|
|
Do Delta thermostats have a "slope control" function?
Delta's thermostats are only available in the DTE series (variety 1.5 and above) with the "slope control" function.
Illustrate the following examples:
For example: PV=20°C, SV=100°C, slope 10.0°C/min
Then (100 – 20)/10.0 ...
|
|
Inverter application for heat dissipation to solve the precautions - Delta
The transformer DC resistance tester uses the 32-bit ARM core as the core of processing, controls the whole machine, and automatically completes the functions of self-calibration, current stabilization judgment, data processing, resistance value display, etc., and can measure the DC resistance of various types of transformers and transformers.
...
|
|
Delta's inverter product model
Delta's VFD inverters have established extensive brand awareness in industrial automation stores. Each series of products is designed for different operating needs such as torque, loss, overload, overspeed operation, etc., and is adjusted according to the characteristics of different industrial machinery; It can provide customers with a variety of choices, and a wide range of ...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|