What are the benefits of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters, so that you don't need to spend money to buy accessories of the same power, and also save maintenance costs, why not!
1. Yaskawa inverter G5-G7 power correction
Enter the menu, A01=4, and then return to 02-04, which is the power data, and the factory voltage of rehabilitation has also changed after the change.
2. Sanken inverter IHF-IPF-SHF series
Enter the CD900 number parameter and enter 365 to admit (change 2 times) and then find CD202 and enter 365 to see the power and voltage parameters, 4-5.5 means 400V-5.5KW, first correct the voltage and then admit to correct the power, after the completion press the admit button and exit.
3. Schneider inverter power correction
After the Schneider inverter replaces the motherboard, it will alarm the CFF when it is powered on, and then press the ENT button 3 times in succession to recover and leave the factory, and the power and voltage will be automatically matched.
4. Siemens 420-430-440 inverter power correction
After changing the motherboard, the power-on appears normal, but many parameters are gone, then enter the No. 3 menu to change the value inside to 3 and then admit, find the P0201 parameter, and then change the value inside to 0 After the power is off and does not appear, then power on, you will find that the display is displayed---- stays for about 5 seconds and recovers normally. At this point, you will find that all the parameters are available, and the power voltage is exactly matched to the machine.
5. Emerson inverter EV2000 power correction
Enter the menu, find FU-000 and correct the value inside to FA58, and then change the code in FU04, 11=7.5KW12=11KW13=15KW21=90KW
6. Delta's inverter power correction method
Enter in the parameter 00-07 (old version 57522, new 33582), and then find the 00-02 parameter and change it to 2 to show err, and then change the value in 00-00 to correspond to the power code on the clarification book, which is OK.
7: ABB inverter ACS800RDCU-02C board power parameter correction method
Enter 9903 and change to YES to enter 1603 to 564 to enter 11206 to pick XXNONE
Then power off and power on, enter 1603 to change to 564, enter 11206 to select the required power (such as 170-3), initialize the parameters, power off and then power on, the above method is suitable for all RDCU boards with different power before version number 7200 to correct each other.
RDCU power change process for 7200 and later versions:
Enter 9903 to change to YES, enter 1603 to change to 564, enter 11221 to select the required power (such as 170-3), enter 9903 to change to YES, power off and power on.
Note that 11219 to 11223 are different power levels, please note that for the normal use of ABB inverter, please do not operate and correct at will, otherwise it will lead to the loss of normal operation parameters.
8: Correction method for the power of the control board of the SY33200SY3300 of the day:
Power on, enter 299 in P0911, and then enter the changed power in P0912. Finally, enter 11 in P0912, pay attention to whether the hardware R164R165R176R177 of the motherboard is 10K, and change the small power to the high power to reduce R164 and R176 short-circuited
Filler: The motherboard of the daily inverter AY3200SY3300 is universal, and after the power of the motherboard is changed, you can change a few resistors on the motherboard
9. Ou Rui inverter F1500 board change power
The power of the inverter is the rated power marked by the factory, the inverter with a large power can be a frequency converter with a small power point, only need to input the given value of the load current into the corresponding power current value, it can be used, the inverter with less power can not be changed to a high-power application, the thyristor current of his internal circuit is limited, and the overload will damage the inverter,
10: Leifeng LF2000 inverter correction power
Find the parameter group O1-04 and change it to MOUDBUS, then enter O2-04 and change it to the corresponding power code, and then restore it to the factory settings
11: How to correct the power of Fujifilm G11 motherboard?
Double-key operation STOP+RESET abort key plus key or down key, first press the PRG key, enter the menu, and then press the >> and PRG keys together to enter the U parameter group, find U50, so that you can correct the power you want. The replacement of the driver board with the motherboard
(1) 7.5G11 - 18.5G11 power level series, the capacity of the P-type inverter and the capacity of the G-type inverter with a small capacity can be exchanged;
(2) When replacing the motherboard of E-type inverter with different power, first enter the F00 function code, press and hold the Stop, Run and Pro keys together to enter the U parameter (it is necessary to short-circuit the THR and CM terminals and FWD and CM are disconnected), and select the main control program parameter settings with the same capacity as the main body of the inverter; Secondly, the parameters of F01-F06 should also be revised or recognized as required, and the process is the same as that of F00; When you have corrected the U-parameters, be sure to remember to re-fix the factory settings to save the corrected U-parameters.
(3) G/P motherboards of different capacities can be exchanged within a certain capacity range (more than 30KW is the same specification and size), and the C parameters, process, and process of correction in the main control program are very different from those of E-type machines.
12: Fujifilm P9/G9 correction power, type, voltage level method
Press the reset key + PRG key, when the C parameter appears, press the up arrow key or the down arrow key to find C08 = capacity or >> key + PRG key U00, first correct 131 = 0.4G132 = 0.75G...... 136=5.5G/7.5P…… 141=22G/30P… Press the data key to store after the correction and use the >> key + up arrow key to correct C05=G/P type G=0, P=1 after the correction and press the data key to store
13: PI2000 rewrites the setting method
(1) Set C01 to 222 to enter P14
(2) Set P14 to 3 to rewrite the CPU, then PI2000 is displayed, C01 is set to 222 to enter P14 parameter setting, P14 is set to 2, P01 is set to model G, F, P02 sets the inverter voltage 380V, P03 sets the rated current of the inverter, P04 sets the voltage to appear, and P05 sets the current to appear.
14: Delta's A-series inverter
The keyboard of the correction parameters is determined, resulting in most of the parameters cannot be corrected, the clarification book does not clearly explain how to unlock the keypad lock, press MODE and RESET together to display P256 (P256 does not clarify what it means in the clarification book), press ENTER to correct this parameter, change 00 to 01, and press ENTER to exit to correct all parameters.
|
More on that
|
Misunderstandings of power-saving and energy-saving use of inverters
Industrial control automation products inverters are depicted as power-saving, energy-saving control automation products, therefore, many people will think that as long as the equipment is installed with inverters, it will be able to save energy, but this is not the case.
The inverter of industrial automation products itself produces energy-saving ...
|
|
Precautions for initial installation of Delta inverters
Delta's inverters should be thoroughly inspected for the first time or after long-term installation. The items and methods of inspection are as follows:
1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dried for 4 hours (60°C) or ...
|
|
How the components of the inverter work – Delta
1. Inverter element - rectifier
Since it is difficult to change the frequency of the communication sine wave in the form of communication, the first operation of the inverter is to convert the waveform into direct current. To make it look like an AC, it is relatively easy to operate the DC. The most important component of all inverters is a ...
|
|
Delta's high-performance servo ASDA-A3 series is a new product
With the rapid development of automation technology and shopping malls, customers have higher and higher requirements for the speed, accuracy and function diversification of servo products. In order to get used to the needs of shopping malls, recently, Delta launched the high-performance motion control high-end AC servo system ASDA-A3 series ...
|
|
Rated current design of inverter leakage circuit breaker - Delta
1. Install AC reactor and DC reactor. When the capacity of the inverter is greater than 500kva in the distribution transformer, and the transformer capacity is more than 10 times the capacity of the inverter, an AC reactor is installed on the input side of the inverter. And when the output voltage of the distribution transformer is unbalanced and uneven in three phases ...
|
|
Precautions for Delta's DPA pressure sensor
1. When the device is installed, leave the place with high voltage and strong high-frequency noise to prevent disturbance. Prevent use in places where the following conditions occur:
(a) Excessive dust and corrosive gases; (b) high humidity and very high radiation; (c) ...
|
|
Delta's inverter fault warning solution
Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ
Fault Codes:
noCL
Fault clarification:
The lack of oil is correct
Solution:
1. Check the fuel level of the fuel tank
2. Check whether there is any leakage on the oil road.
|
|
Regular diagnosis and repair method of Delta servo motor
1. Common faults of motor heating up too high or smoke motor
Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low;
Overhaul...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Analysis and correction of the cause of Delta servo drive alarm
Analyze and correct the cause of Delta servo drive alarms.
Control current and undervoltage protection.
Alert Number: 11.
Reason: The voltage at the end of the dynamic DC bus is lower than the specified value. Due to the instantaneous shortage of power supply capacity, the control voltage is too low.
Measure: Measure the DC bus ...
|
|
Delta inverter parameter replication error solved
1. SE2 parameter imitation error
Problem Description:
Keypad Imitation Function Fault Correction 2
Solution:
1. The Keypad imitation action is completed, and the inverter parameters are written into error
2. SE1 Parameter Imitation ...
|
|
How to use a PC to control Delta's inverter
Problem Description:
How does Delta inverter use a PC to control it?
Solution(s):
The communication interface of Delta's inverter is based on RS485 and the ModBus communication pattern commonly used in the general industry for material handing.
|
|
Inverter technology is a motor control method – Delta
When you are using the motor, if you simply change the frequency, your motor will most likely be burned out. This problem is especially acute when the frequency is reduced. In order to prevent the motor from burning out, the inverter must change the voltage at the same time as the frequency.
...
|
|
The reason for the slow response after the frequency converter potentiometer adjusts the frequency - Delta
The external use resistor is an external operation form of the inverter, which controls the inverter through the external operation signal generated by the external starting switch and frequency setting potentiometer. The regular external voltage signal of different inverters is different.
...
|
|
Delta's inverter external positive and reverse operation mode
1. The external control panel is rotated and operated
After selecting the upper or lower button on the panel, the Frd inverter will rotate forward if you select the inverter, and the rEu inverter will rotate
2. The external control terminal is rotated
Access via external terminals ...
|
|
Delta's C-series evolution is complete—C2000+ inverter
Those who know more about Delta's automation know that Delta's inverters have two main series: "M300" and "C2000".
"Compact Inverter M300 Series": This series has been introduced many times before, including ...
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|
Consider the timing of increasing the capacity of the inverter - Delta inverter
1. The rated current of the inverter is low
As mentioned above, when the rated current of some inverters is less than the rated current of the motor of the same capacity, the inverter with a larger gear should be considered according to the load condition of the motor.
2. The motor may be overloaded for a short time
Since the electric motor ...
|
|
Comparison of three speed regulation methods for Delta DC motors
There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation.
1. Armature loop string resistance
The applied resistor is connected into the armature circuit to achieve the purpose of speed regulation.
Speed Direction: Add ...
|
|
Safety precautions for Delta servo motors
Delta's servo motor system is planned for industrial use, and it is necessary to have a full understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and the mechanical equipment, and to ensure that the communication motor can be used correctly, please read this safety precaution before installing the machine.
...
|
|