Method 1
1. Hit the PLC from RUN to STOP
Mitsubishi's PLC has a special method of setting landing keywords, and it is necessary to ensure that the PLC is in a state of shutdown in order to successfully write the landing keywords.
When the RUN is running, a message will be displayed that says "PLC login keyword cannot be performed" when the write is performed.
2. Select the menu "Online" --> "Login Keywords" --> "New Login, Change" to complete the password setting.
Method 2
1. Power on the PLC, connect with the computer through the programming cable, select "Online", → "Login Keyword" → "New Login" in the programming software GX-DEVELOPER, and write the password to be set in the box after the "keyword" in the pop-up dialog box, and the set password is 8 digits, which can be 0-9 numbers or A-F letters.
2. Click "Fulfill" after writing, and enter the same password again according to the prompts. The protection level of PLC is also different for different code settings, the initial text of the keyword is A, D-F, 0-9 will prohibit all operations, the initial text of B will prohibit the reading and writing of the program, and will not constrain the monitoring and change of the current value, the initial text of C only restricts the writing of the program, and does not constrain other operations.
Method 3
1. First of all, choose the serial port debugging program. It is recommended to use the MultiCOMWatch debugger
2. For the plc of Mitsubishi FX series, its cipher verification process is through the clear code method, so the cipher code can be obtained through the supervised method. When the programming software is connected to the PLC, the PLC will send the code to the programmer (computer) and wait for the correct code to be entered for verification.
Method: Activate the MultiCOMWatch debugger to open Com1 (depending on the port connected to the PLC).
Confirm the Mitsubishi PLC type. Select according to the PLC type, and enter the corresponding string in the text of the multi-serial debugger. ( Description STX=02 ETX=03 )
PLC Type: Text corresponds to string, HEX pattern corresponds to string
FX2 STX0700808ETX6A 02 30 37 30 30 38 30 38 03 36 41 32
FX2N STX0300808ETX66 02 30 33 30 30 38 30 38 03 36 36 32
FX2_EPROM STX0800808ETX6B 02 30 38 30 30 38 30 38 03 36 42
FXON/FXOX STX0800808ETX6B 02 30 38 30 30 38 30 38 03 36 42
FX1N/FX1X STX0800808ETX6B 02 30 38 30 30 38 30 38 03 36 42〈正确〉
A-Series:
Sent: A2 07 00 FF 02 05 AE 00 08 C3
Acceptance: 0B 00 FF 02 00 AA 77 55 BB EF CD AB A4 00 Cipher: ABCDEF
Sent: A2 07 00 FF 02 05 AE 00 08 C3
Acceptance: 0B 00 FF 02 00 AA 77 55 BB C1 B1 A1 A4 Code: A1B1C1
Analysis: The cipher is the character between BB and A4 in the return character, which is read from right to left every 2 characters.
After understanding the above strings, you can write a program that reads and writes cipher codes in VB or other programming languages. If you want to know more about the communication between the PLC and the computer, you can use the hardware supervised communication method to get the whole process.
3. After sending, a string of strings will be displayed in the acceptance box, which is the password back, if you can't see it, copy these strings into the HEX pattern and send them once to see. (Remember to disconnect the PLC before sending).
|
More on that
|
The cause of the failure caused by OC - Mitsubishi inverter
1. Aging of drive circuit
Due to the long-term use, it will inevitably lead to the aging of components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm often appears as soon as it is running.
...
|
|
Mitsubishi inverter capacity selection
The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method.
1. When accelerating or operating at constant speed
The efficiency of the inverter is the output current, that is, how much current the inverter can provide to the motor. Frequency converters ...
|
|
The role of Mitsubishi inverters in energy conservation and emission reduction
1. Descend the starting current of the motor
When the motor is started, due to the influence of inertia and load, there will be a large starting current. This current causes fluctuations in grid voltage and energy additions to the grid. The use of frequency converters can effectively solve this problem. After conditioning inverter ...
|
|
Mitsubishi PLC command negation, empty operation and END, etc
Introduction to Mitsubishi PLC directives such as negation, air operation and END
The INV (Inverse) command is represented by a short 45° slash at the top of the ladder diagram, which negates the result of the operation before the execution of the instruction, and the result of the operation is 0 ...
|
|
Mitsubishi FX5U series PLC ten advantages
1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input ...
|
|
MITSUBISHI COLLABORATIVE ROBOT MELFA ASSISTA
With the popularization of industrial robots in the production site, more and more Mitsubishi collaborative robots, Mitsubishi robots, MELFA ASSISTA, RV-5AS-D on-site issues need to be solved urgently, such as the need for more robot programming engineers, adding labor costs; The teaching is cluttered, and a large number of non-...
|
|
The inverter completes the multi-speed function - Mitsubishi
The inverter can be preset with a number of different speed points, and then complete the scheduling of multiple speed stages. The specific completion method is as follows:
You can set a number of different speed points in the VFD, and you can generally set the maximum speed, minimum speed, and several center speed points.
According to the needs, choose ...
|
|
Mitsubishi tells you what IGBT is
Mitsubishi Electric IGBT is the English word Insulated Gate Bipolar Transistor, which means insulated gate bipolar transistor in Chinese.
Functionally, IGBT is a circuit switch, and the advantage is that it uses electricity.
|
|
Mitsubishi servo teaches you to choose a good robot
When evaluating which process is suitable for which approach in the production environment, consider the problem you want to solve and consider all the costs that the robot can save: reduce waste, improve efficiency, improve productivity, improve safety, or reduce labor costs. These costs ...
|
|
How to write a holding circuit for Mitsubishi PLC
There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed once through the insistence circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit.
...
|
|
Mitsubishi servo motor AL.50 alarm solution
During the operation of the Mitsubishi servo motor, it may be possible to display an AL.50 alarm under certain circumstances (such as after a period of continuous operation), what is going on? And how to solve it?
First of all, we need to know that the reason why the AL.50 alarm is presented is because the Mitsubishi servo ...
|
|
Mitsubishi servo selection robot method
When evaluating which process is suitable for which process to use in the production environment, it is necessary to carefully consider the problem you want to solve and consider all the costs that the robot can save: reduce waste, improve power, improve yield, improve safety or reduce labor costs. These costs ...
|
|
Mitsubishi inverter fault visual inspection method
The intuitive method refers to the search and analysis of faults based on the external manifestations of Mitsubishi inverter defects without any instruments. The visual method includes an unpowered view and a power-on survey. In the overhaul, the first thing to do is to check without power, that is, to use the human sensory organs (eyes, ears, hands, nose) to check the relevant plug-in.
|
|
Advantages of Mitsubishi Electric fresh air system
Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just replace the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless.
...
|
|
Inverter overload fault factor - Mitsubishi inverter
1) The mechanical load is too heavy
The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...
|
|
Mitsubishi servo motor code failure
1. Disadvantages of UVT
The common undervoltage detection point is the voltage on the DC bus side, and a low voltage value is sampled after dividing the voltage by the large resistance resistor, and the output voltage is normal signal, overvoltage signal or undervoltage signal after comparing with the standard voltage value. About Mitsubishi A500 series inverter voltage signal ...
|
|
Pay attention to the problem when choosing an inverter - Mitsubishi Electric
The current value of the motor is used as the basis for the selection of the inverter, and the rated power of the motor is only for reference.
Compared with the general squirrel cage motor, the winding motor simply has the problem of overcurrent tripping, and the slightly larger capacity than the usual ...
|
|
Programming element for Mitsubishi FX2N series PLCs
Each element of the Mitsubishi FX2N series PLC is indicated by a characteristic letter, such as X indicates the input relay, Y indicates the output relay, M indicates the auxiliary relay, T indicates the timer, C indicates the condition element, etc., and these elements have a specified number.
...
|
|
Mitsubishi PLC controls the control method of the inverter
1. Use the switching signal of PLC to control the inverter
The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and SG input ports of the inverter. The PLC can control the inverter through the program.
|
|
Advantages and applications of servo motors - Mitsubishi
First of all, what are the advantages of servo motors compared with other motors (such as stepper motors):
1. Accuracy: Closed-loop control of azimuth, speed and torque is realized; Overcome the problem of stepper motor out-of-step;
2. Speed: high speed ...
|
|