The role of Mitsubishi inverters in energy conservation and emission reduction

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1. Descend the starting current of the motor

When the motor is started, due to the influence of inertia and load, there will be a large starting current. This current causes fluctuations in grid voltage and energy additions to the grid. The use of frequency converters can effectively solve this problem. By conditioning the output voltage and frequency of the inverter, the current at the start of the motor can be controlled, and then the energy consumption of the grid and the starting loss of the motor can be reduced.

                            The role of Mitsubishi inverters in energy conservation and emission reduction

2. Reduce the operating energy consumption of the motor

The energy consumption of the motor is mainly related to the speed and load of the motor. The traditional motor control method is to control the speed of the motor by adjusting the power, which has the problem of energy waste. The inverter can control the operating energy consumption of the motor by adjusting the speed of the motor, and then complete the purpose of energy saving and emission reduction. The inverter can automatically adjust the speed of the motor according to the change of the motor load, so that the motor is in the best operating condition during operation, and then complete the largest degree of energy consumption reduction.

3. Improve production power and product quality

Traditional motor control methods often have problems such as unstable operation, high noise, many wearing parts, and high maintenance costs, which will have an impact on the output power and product quality. The inverter can improve the speed accuracy and control accuracy of the motor, improve the operation stability and accuracy of the motor, and then improve the production power and product quality.

More on that
Mitsubishi servo motor one-button adjustment function Mitsubishi servo motor one-button adjustment function

In the MR Configurator2 servo commissioning software, Mitsubishi has developed a "one-button adjustment" function to solve the problem of rigid noise of servo motors, as follows: 1. Set PA08 to 0003 and adjust the gain to ...

Mitsubishi PLC communication detection steps Mitsubishi PLC communication detection steps

When you are ready to communicate through AJ71QE71, perform the ping procedure in MS-DOS mode to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. Support communication with Weilun touch screen through serial port. Under...

Mitsubishi FX series PLC fault diagnosis method Mitsubishi FX series PLC fault diagnosis method

1. Power indication (LED indication) When power is supplied to the Mitsubishi PLC root unit, the [POWER] LED indicator light installed on the surface of the root unit turns on. If the power supply is closed but the [POWER] LED does not illuminate, please acknowledge the power wiring. In addition, if the same power supply has a drive sensor, etc. ...

Mitsubishi servo motor code failure Mitsubishi servo motor code failure

1. Disadvantages of UVT The common undervoltage detection point is the voltage on the DC bus side, and a low voltage value is sampled after dividing the voltage by the large resistance resistor, and the output voltage is normal signal, overvoltage signal or undervoltage signal after comparing with the standard voltage value. About Mitsubishi A500 series inverter voltage signal ...

The working principle of the servo motor of the Mitsubishi CNC system The working principle of the servo motor of the Mitsubishi CNC system

1. The servo mainly relies on the pulse to position, basically it can be understood in this way, the Mitsubishi CNC system repair servo motor receives 1 pulse, it will rotate the angle corresponding to 1 pulse, and then complete the displacement, because, the servo motor itself has the function of announcing the pulse, so the servo motor ...

The matching relationship between the inverter and the motor - Mitsubishi The matching relationship between the inverter and the motor - Mitsubishi

It has become an irreversible trend to drive the motor through the inverter, and in the actual application process, because the matching relationship between the inverter and the motor is not very reasonable, it often leads to some problems. When selecting an inverter, you should fully understand the load characteristics of the equipment driven by the inverter. Ms. Ginseng ...

What are the main factors of interference in Mitsubishi PLC system? What are the main factors of interference in Mitsubishi PLC system?

(1) Radiative dry disturbance from space The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...

Mitsubishi inverter heat dissipation causes and countermeasures Mitsubishi inverter heat dissipation causes and countermeasures

1. Whether there is abnormal change in the sound during the operation of the equipment, including whether there is oscillation during the operation of the motor. 2. Whether the ambient temperature of the inverter installation is too high or too low, the working temperature is generally required to be in the range of -10°C - +40°C, and it is better to be about 25°C. ...

Z series and A200 series inverter fault solving Z series and A200 series inverter fault solving

Low-power Z024 series inverter, our common problems include OC, ERR, no appearance, etc. There are two possible causes of OC. (1) Aging of the drive circuit Because the use of a long period of time will inevitably lead to the aging of components, which will cause the driving waveform to occur.

Installation and maintenance of Mitsubishi inverters Installation and maintenance of Mitsubishi inverters

1. Mitsubishi inverter is more and more widely used because of a series of advantages such as wide speed regulation range, high speed regulation accuracy, fast dynamic response, high work efficiency, convenient operation and easy interface with other equipment. Because of the high common sense content of Mitsubishi inverter and the messy technology, how to use Mitsubishi inverter well...

Mitsubishi PLC network structure Mitsubishi PLC network structure

1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment and sensors and drive equipment, which is the low-level network of the entire network system. The CC-Link fieldbus connection is selected, and the number of wiring is greatly reduced, and the system maintainability is improved. Whereas...

Mitsubishi drive functions and functions Mitsubishi drive functions and functions

1. Control the start, stop, speed and so on of the servo motor; 2. Carry out various maintenance on the motor (overload, short circuit, undervoltage, etc.) 3. React to external signals and control servo motors (position, speed, torque) through internal PID conditioning; ...

Mitsubishi PLC set and reset command use example Mitsubishi PLC set and reset command use example

1 SET Directive The SET instruction is called an enthronement instruction. Its function is: to drive the coil, so that it has a self-locking function, and insists on the connection condition. In the diagram, when the moving contact X0 is closed, the SET command is executed to turn on the Y0 coil. After X0 is disconnected, the Y0 coil continues to insist on the ON condition, ...

Mitsubishi inverter FR-E024-0.75K repair Mitsubishi inverter FR-E024-0.75K repair

Type: FR-E024-0.75K Fault: The boot cannot be started Maintenance: This machine does not provide any symptom information, and the display screen shows an "E.THT" error when the motor is to be started after powering on. Check the instructions refer to the ...

Introduction to the Mitsubishi PLC encryption process method Introduction to the Mitsubishi PLC encryption process method

The encryption process is as follows: ** Open the serial port for the first time [00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here) [00000000] IOCTL_SERIAL_SET_LINE_CONTROL StopBits: 1, Parity: Ev ...

Programmable Controller System Design and Debugging Steps – Mitsubishi PLC Programmable Controller System Design and Debugging Steps – Mitsubishi PLC

The main steps in the planning and commissioning of the programmable manipulator application system (1) In-depth understanding and analysis of the process conditions and control requirements of the controlled target a. The controlled target is a controlled mechanical, electrical equipment, production line or ...

Query Error Code Method – Mitsubishi Query Error Code Method – Mitsubishi

Error Number (D8063): 6314 ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL) Error content: Parallel operation string abnormal Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...

Methods for shortening the scanning cycle of PLC programs – Mitsubishi Methods for shortening the scanning cycle of PLC programs – Mitsubishi

1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers. 2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S; 3. Try to prevent the transformation of data types, ...

Advantages and disadvantages of different output types of PLC – Mitsubishi Advantages and disadvantages of different output types of PLC – Mitsubishi

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...

Review and comparison of Mitsubishi PLC control inverter methods Review and comparison of Mitsubishi PLC control inverter methods

1. The switching signal of PLC controls the inverter The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top