1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input and 1-channel analog output.
Parameters can be used to set the transmission of values, the size of the shares, and the output of alarms.
3. Built-in SD memory
The built-in SD card slot is very convenient for mass production of program upgrades and settings.
4. Built-in RS-485 port (with MODBUS function)
Corresponding to the MODBUS function, it can be connected to PLC, sensors, temperature regulators and other peripheral equipment, and can be connected to 32 units.
5. Safety
MELSEC IQ-F can use security functions (file code, long-distance code, security code) to prevent data theft and illegal implementation by third parties due to illegal login.
6. High-speed system bus
Equipped with a high-speed CPU, the MELSEC IQ-F achieves a communication speed of 1.5K bytes/ms (about 150 times that of the FX3U), which can be used to the maximum even when multiple modules are expanded.
7. No battery required, simple protection
The program can be held without batteries, and the timer data can be held for 10 days through a large capacitor
8. Built-in Ethernet port
The Ethernet communication port can connect up to 8 computer devices on the network, and can correspond to the protection of long-distance equipment or seamless SLMP communication between host computers.
9. Advanced positioning function
Built-in 4-axis, 200KHZ positioning function. It can be used through special instructions to achieve abort positioning, variable speed operation, and simple interpolation function.
10. Advanced motion control function
|
More on that
|
Advantages and disadvantages of different output types of Mitsubishi PLC
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The biggest advantage is that it is accustomed to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...
|
|
Internal data structure of the Mitsubishi PLC FX series
A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following ways in terms of structure or number system.
(1) Decimal number
Decimal numbers are also known as word data in PLC. It is first and foremost ...
|
|
One-button adjustment function for Mitsubishi servo motors
After the first installation of different servo motors on the machine, they may be poorly matched to the machine during operation, resulting in vibration, noise and other phenomena.
The cause of the problem is a mismatch between parameters such as the rigidity of the servo motor and the load-inertia ratio and the machinery. Due to the large number of parameters that affect ...
|
|
Mitsubishi PLC set and reset command use example
1 SET Directive
The SET instruction is called an enthronement instruction. Its function is: to drive the coil, so that it has a self-locking function, and insists on the connection condition. In the diagram, when the moving contact X0 is closed, the SET command is executed to turn on the Y0 coil. After X0 is disconnected, the Y0 coil continues to insist on the ON condition, ...
|
|
Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment and sensors and drive equipment, which is the low-level network of the entire network system. The CC-Link fieldbus connection is selected, and the number of wiring is greatly reduced, and the system maintainability is improved. Whereas...
|
|
What are the main factors of interference in Mitsubishi PLC system?
(1) Radiative dry disturbance from space
The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...
|
|
Mitsubishi Electric instruction format
(1) Arbitrary axis AC command (G140)
G140 Instruction Address = Axis Address Instruction Address = Axis Address ... ;
Command Address: Arbitrary Axis AC Command (G140) After that, specify the 1-character address set by the parameter (#12071-#12078) to be used for moving commands, etc.
|
|
How Mitsubishi PLC works
A. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting.
B. Each scanning process. The convergence samples the input signal. The convergence rewrites the output signal.
C. Component image register ...
|
|
Mitsubishi PLC Comparison Instruction Application
1. Compare the instruction CMP
1)。 16-bit arithmetic (CMP, CMPP) compares the contents of the comparison value S1 with the comparison source S2, and according to the results (small, - zhi, large), D, D+1, D+2 - one is ON.
...
|
|
Mitsubishi servo system failure type
The origin orientation is incorrect, and the encoder debugs/zeros the bit
Replacement of bearings, wear of bearing grooves, cracking of the rotor, cracking of the shaft
Gear groove wear
The magnet bursts steel, the magnet falls, gets stuck and doesn't move
Encoder wear, code/glass disc wear and crack
...
|
|
Mitsubishi PLC's communication inspection method
When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port.
...
|
|
Introduction to the Mitsubishi PLC encryption process method
The encryption process is as follows:
** Open the serial port for the first time
[00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here)
[00000000] IOCTL_SERIAL_SET_LINE_CONTROL StopBits: 1, Parity: Ev ...
|
|
Mitsubishi takes instructions and outputs instructions
1) LD (take instruction) A command to connect a normally open contact with the left bus, and every logic line that starts with a normally open contact is used with this instruction;
2) LDI (Reverse Instruction) A normally closed contact is connected to the left bus to the instruction, each ...
|
|
Mitsubishi Electric develops production line improvement technology
TOKYO, March 26, 2020 – Mitsubishi Electric Corporation (TSE: 6503) announced today that it has developed a new technology for efficient design and material flow of production floor layouts and accurate estimates ® of productivity using Mitsubishi Electric's Maisart *AI.
|
|
Ground leakage current of Mitsubishi inverter and countermeasures thereof
There is electrostatic capacitance between the input and output wiring of Mitsubishi inverters and other wires, between the ground and the motor, and there is a leakage current flow. The leakage current value is affected by factors such as electrostatic capacitance and carrier frequency, and the leakage current is high when the carrier frequency of the inverter is set high and the leakage current is operated under low noise conditions.
|
|
Debugging method of servo motor - Mitsubishi
1. Initialize parameters
Before wiring, initialize the parameters.
On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by default; Save this state to ensure that this is the status when the control card is powered on again.
...
|
|
Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. Combine...
|
|
Mitsubishi PLC FAQs
1. How to connect a PNP three-wire proximity switch to the input port of FX3U PLC.
Answer: The signal output termination of the PNP three-wire system close to the switch is connected to the input port of the PLC, such as X0, and the 0V end of the PNP type close switch to the 0V terminal on the PLC, and the S/S terminal and the 0V terminal ...
|
|
The origin of Mitsubishi servo motion control is returned
1. The so-called positioning is to let the servo motor go to a confirmed position.
2. This direction can be so incremental, or so ***. For example, we are now on the road, and we have to go forward 10 meters, which is equivalent to adding 10 meters to our bearing.
|
|
Mitsubishi PLC commonly used circuit programming application
1. Self-locking and interlocking circuits
1) Self-locking circuit: The self-locking circuit is often used for the start-stop control of the motor.
Press the start button X0 motor to start running, release the start button to keep the motor running, press the stop button X1 motor to stop running.