1. 3-pin relay wiring

The common 3-pin relay is the car horn relay.

No. 1 is the contact terminal, which connects the load;

No. 2 is the common terminal between the contact and the coil, which is connected to the power supply;

No. 3 is the coil terminal, which connects to the button switch (such as the horn button on the steering wheel).

Press the button switch, 2, 3 on, the coil is energized, the contact is closed, 1, 2 is on, and the horn makes a sound.

2. 4-pin relay wiring

The 4-pin relay is the most common SPST relay.

Pin 1 and 2 are coil terminals, and pins 3 and 4 are contact terminals.

1. 2 conduction, coil energization, internal mechanical transmission, 3 and 4 contacts are closed (normally closed type is disconnected), and the load loop is turned on.

3. 5-pin relay wiring

The 5-pin relay is a common SPDT relay.

1 and 2 are coil terminals, 3 are common contacts, and 4 and 5 are normally open and normally closed contacts.

Initial state, 3, 5 contacts are on, and load 5 is working; After the coil power supply is powered, 1 and 2 are turned on, the coil is energized, the 3 common contacts are switched to close with the 4 normally open contacts, and the load 4 starts to work.

Fourth, 6 pin relay wiring

The conventional 6-pin relay is not much different from the 5-pin principle, that is, there is an additional common terminal, and the two terminals 1 and 6 are connected together and act as a common terminal at the same time.
Peel magnetic relays - what are the connection methods of relays?

More on that
How to use Pilz safety relays How to use Pilz safety relays

When using Pilz safety relays, it is necessary to pay attention to the correct way to use them. The key to the correct use of safety relays is to protect the wiring method of the input circuit. In general, the wiring method of the safety relay is divided into three types.

Functions of Pilz Functions of Pilz

1. When the load exceeds the action current, the circuit will be automatically cut off; 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for the judgment of the fault part; 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply; 4. For other reasons, the shell ...

Pilz presents a new product: Safe Protective Area Monitoring is also available for robotic applications Pilz presents a new product: Safe Protective Area Monitoring is also available for robotic applications

For the monitoring of safe protected areas under harsh conditions, such as dust, dirt, rain, light, sparks or shocks, the safety radar sensor PSENradar in combination with the configurable small controller PNOZmulti 2 offers the best solution: in addition to outdoor applications as well as woodworking and ...

Common faults of Pilz safety relays with contacts and how to deal with them Common faults of Pilz safety relays with contacts and how to deal with them

The most common ones are the following: (1) Contact failure 1. The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion formed on the contact and the pit biting each other), fusion welding, or cold welding. 2. Due to the contact resistance becoming large and unstable, the circuit cannot be normal ...

Pierz supports ACMI S.p.A.'s packaging process Pierz supports ACMI S.p.A.'s packaging process

ACMI S.p.A. is an Italy company specializing in high-tech bottling and packaging lines. Based in Fornovo Taro, in the province of Parma, Italy, the company initially produced palletizers and depalletizers for the food and beverage industry, and later specialized in all packaging processes. For...

Pilz: Safety scanners for AGVs Pilz: Safety scanners for AGVs

Automated Guided Vehicle, abbreviated as AGV, also commonly known as AGV trolley, refers to a transport vehicle equipped with electromagnetic or optical automatic navigation devices, which can drive along the specified navigation path, and has safety protection and various transfer functions. Due to its flexibility, the degree of intelligence ...

Peel magnetic relay - the wiring method of PLC and relay Peel magnetic relay - the wiring method of PLC and relay

1. Y0 is connected to one end of the coil A1 of KA1; 2. The other end of KA1, A2, is connected to 24V; 3. Y1 is connected to A1 at one end of the coil of KA2; 4. The other end of KA2 A2 is connected to 24V; 5. COM terminated to 24V. ...

Pilz: Mechatronics methods for automation Pilz: Mechatronics methods for automation

Smart factories, Industry 4.0 and autonomous production – the mechanical engineering department is now looking forward to a bright future. The pace of innovation and ever-shortening development moments are playing an increasingly important role in the global race. To streamline the engineering process and add reusability to individual components, the regulations ...

Pierre Servo Amplifiers – What are the basic requirements for servo amplifiers? Pierre Servo Amplifiers – What are the basic requirements for servo amplifiers?

Requirements for servo feed systems 1. Wide range of speed regulation 2. High positioning accuracy 3. There is sufficient transmission rigidity and high speed stability 4. Fast response, no overshoot In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...

Pilz was invited to attend the China Equipment Manufacturing Industry Youth Safety Expert Forum Pilz was invited to attend the China Equipment Manufacturing Industry Youth Safety Expert Forum

Recently, the inaugural meeting of the Youth Safety Expert Working Committee of China Machinery Industry Safety and Health Association and the first China Equipment Manufacturing Youth Safety Expert Forum were held in Chengdu, Sichuan.

Peel Magnetic Relays – How to Choose a Solid State Relay Peel Magnetic Relays – How to Choose a Solid State Relay

The naming of solid state relay models has not been unified, and the following conditions should be considered when selecting the manufacturer's manual. (1) Rated input voltage Refers to the maximum allowable effective voltage of a steady-state resistive load that can be withstood under a given condition. When used for inductive loads ...

Peel magnetic relays - analysis of common faults and causes of relays Peel magnetic relays - analysis of common faults and causes of relays

1. Contact failure (1) The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion and pit formed on the contact bite each other), fusion welding, or cold welding. (2) The contact wear of the relay is caused by the absence of arc extinguishing devices or measures, or improper parameter selection, ...

Peel magnetic relay - fault judgment and treatment method of safety relay Peel magnetic relay - fault judgment and treatment method of safety relay

1. Determine whether the safety relay itself is faulty: 1. Separate from the three circuits of short-circuit S10/S12, S11/S12, S21/S22. 2. Turn on the 24V power supply (A1 is positive, A2 is negative), and the Power light should be on at this moment; 3. Reset the S33/S34 terminals, and the K1 and K2 lamps ...

Pilz Switches - Introduction to the use, characteristics and functions of high-voltage load switches Pilz Switches - Introduction to the use, characteristics and functions of high-voltage load switches

(1) Use The high-voltage load switch is an electrical appliance with a function between the high-voltage circuit breaker and the high-voltage isolation switch, and the high-voltage load switch is often used in series with the high-voltage fuse; It is used to control power transformers. The high-voltage load switch has a simple arc extinguishing device, because it can turn on and off ...

Pilz: Designing safe railway sites Pilz: Designing safe railway sites

From hardware components to complete safety concepts: Pilz has extended its industrial expertise from the field of machinery safety and health and safety regulations to railway sites. With many years of knowledge and experience, Pilz has demonstrated the same competence in the railway industry as it does in an industrial environment. Skin...

Wiring method for Pilz safety relays Wiring method for Pilz safety relays

Power supply: AC: Terminals A1 and A2 are connected to the power supply, and the ground wire is connected to the protective ground. DC: A2 is connected to the ground terminal of the power supply. Start-up loop: Auto-start: S13-S14 shorted. Manual monitoring start-up mode: S33-S34 ...

Requirements for safety circuits for Pilz safety relays Requirements for safety circuits for Pilz safety relays

1. When the emergency stop is lifted, the machine cannot be suddenly restarted 2. In case of failure of the machine safety circuit, the power supply of the machine can be stopped 3. When the safety circuit fails, the machine can no longer be started Confirm safe input such as safety switches, light curtains, etc.

Pilz leads the publication of the HRC Safety Application Guide Pilz leads the publication of the HRC Safety Application Guide

With the increasingly widespread use of industrial robots, the trend of China's manufacturing industry to a higher degree of automation has been bright, and the transformation and upgrading of China's manufacturing industry is on the way. The emergence of collaborative robots means that more intelligent robots will become the future intelligent system of China's manufacturing enterprises.

Peel magnetic relays – the five major classifications of relays Peel magnetic relays – the five major classifications of relays

1. Classification by use In terms of use, the classification of relays can be divided into two types: control relays and protection relays. In the meantime: thermal relays, overcurrent relays, and undervoltage relays are all protective relays. And moment relays, speed relays, intermediate relays ...

Pilz: Overrun measurement – for safe distances Pilz: Overrun measurement – for safe distances

On machines with electrosensitive protective devices (e.g. laser scanners or light curtains), safety is ensured by the distance between hazardous movements and electrosensitive protective devices. Where there is intervention/access to the danger zone, there will be no more runaway movements. Overrun is a dangerous movement that stops after a shutdown ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top