How Pilz safety relays are shorted to I10 points

Create Date: 2024-8-30 12:03:23|Source: PILZ/PILZ

Short-circuit method: when FD is displayed, it means that the safety loop is disconnected, at this time, the safety relay CC is disconnected, and the indicator light on the operation board is extinguished, first check whether the safety loop power supply fuse 1F1 (the 6th from the left in the lower row behind the control cabinet) is fused;

2. When short-circuiting is required for maintenance, please use the following methods:

1. A2-A7 short circuit on the operation board: emergency stop switch on the top of the car, emergency stop switch in the car, safety gear switch;

2. A7-A10 short circuit on the operation board: upper and lower limit switches, buffer switches, tension switches;

3. A10-A11 short circuit on the operation board: speed limiter switch;

3. The left wiring in the control cabinet is ranked: the top is the wiring of the rotary encoder, B1 and B2 are the wiring of the brake coil, and the bottom is the internal and external wiring.

4. Short-circuit door lock circuit operation: when an indicator light below the operation panel is extinguished, it means that the door lock circuit is disconnected;

5. If you need to short circuit during maintenance, please use the following methods to operate:

1. A11-HDC short circuit on the operation board: hall door door interlocking;

2. HDC-NC shorting on the operation board: car door interlocking;

3. No. 3 and No. 4 shorts on the operation board: hall, car door interlocking full short-circuit. No. 3 and No. 4 must not be shorted with No. 7, otherwise two to three computer boards will be burned.
How Pilz safety relays are shorted to I10 points


More on that
Pilz is one of the Industry 4.0 Top 100 Pilz is one of the Industry 4.0 Top 100

Allianz Industries 4.0 awarded Pilz the title of "Top 100 Industry 4.0 in Baden-Württemberg". Allianz Industry 4.0 is a network initiated and funded by the Baden-Württemberg Ministry of Economic Affairs. Every year, Allianz provides support for those who have the ability to work...

Peel magnetic relays – a common fault of electromagnetic relays Peel magnetic relays – a common fault of electromagnetic relays

1. After the power failure, the armature cannot be released immediately, which may be due to the stuck movable core, the core air gap is too small, the spring strain and the oil caused by the core contact surface, etc. Universal relay maintenance should be treated differently by the cause of failure, or adjust the air gap to protect it from 0.02 to 0.05 mm, ...

Pilz will be exhibiting at the Hannover Messe 2022 Pilz will be exhibiting at the Hannover Messe 2022

At the Hannover Messe 2022 at the Industrial Fair (30 May 2022 * 2 June), Pilz will be presenting complete automation solutions including security and industrial security that can be automated independently and flexibly. Visitors can enjoy a tour of the Peel ...

PILZ WILL BE EXHIBITING AT THERMPROCESS 2023 PILZ WILL BE EXHIBITING AT THERMPROCESS 2023

From June 12 to June 16, 2023, Pilz will be present at the THERMPROCESS trade fair in Düsseldorf, Germany, at booth B10 in Hall 9. Germany Düsseldorf Thermprocess is Germany most important trade fair for industrial furnaces and heat treatment ...

Peel magnetic relay - relay common faults and solutions Peel magnetic relay - relay common faults and solutions

First, the contact is loose and cracks The contact is the electrical touch part of the relay to complete the switching load, and the contact of some products is riveted and pressed, and its primary disadvantage is that the contact is loose, the contact cracking or the scale azimuth error is too large. This will affect the touch reliability of the relay. ...

Peel magnetic relay - the wiring method of PLC and relay Peel magnetic relay - the wiring method of PLC and relay

1. Y0 is connected to one end of the coil A1 of KA1; 2. The other end of KA1, A2, is connected to 24V; 3. Y1 is connected to A1 at one end of the coil of KA2; 4. The other end of KA2 A2 is connected to 24V; 5. COM terminated to 24V. ...

Peel Magnetic Relays – How to Choose a Solid State Relay Peel Magnetic Relays – How to Choose a Solid State Relay

The naming of solid state relay models has not been unified, and the following conditions should be considered when selecting the manufacturer's manual. (1) Rated input voltage Refers to the maximum allowable effective voltage of a steady-state resistive load that can be withstood under a given condition. When used for inductive loads ...

Peel magnetic relay – the difference between a safety relay and a normal relay Peel magnetic relay – the difference between a safety relay and a normal relay

1. The shape is larger The dimensions of safety relays are different from ordinary relays, and safety relays are larger. 2. Modules instead of components A safety relay is a module, not an electronic component like a normal relay. 3. Color Quiet...

Pilz has launched the new PNOZmulti2 base module PNOZ m C0 Pilz has launched the new PNOZmulti2 base module PNOZ m C0

Pilz's new PNOZmulti2 base module, PNOZ m C0, is sure to be the next big thing...... The reason is simple, it has a compact design, a beautiful price, and the functionality is not "ambiguous" at all, after all, it belongs to the PNOZmulti family.   The basic module of PNOZ m C0 ...

Pilz: Configurable safety relays with reliable delivery times Pilz: Configurable safety relays with reliable delivery times

Have you encountered any of the pain points of these safety relay applications? Since the invention of the first emergency stop safety relay by Pilz in 1987, after twenty or thirty years of development, the current safety relay market can be described as a hundred flowers blooming and a hundred schools of thought contending. Although, the currently selectable security relay ...

Pierz: The safety protection of the press can be so neat! Pierz: The safety protection of the press can be so neat!

1. Presses = inflexible? In the past, presses were often labelled as "sluggish", "inflexible" and "high-risk". With the development of technology, safety solutions for presses are emerging one after another, and the safety of presses is greatly improved. In the event that security is ensured...

How Pilz replaces the safety switch How Pilz replaces the safety switch

1. First, unscrew out the fixing screws of fixing the noodle frame and the water baffle plate according to the above steps; 2. Unscrew out the two screws that fix the safety switch, and pull out the two lead pins connecting the safety switch; 3. Replace the new safety switch and assemble it according to the original steps. Electrical safety switch ...

Peel magnetic relays - what are the connection methods of relays? Peel magnetic relays - what are the connection methods of relays?

1. 3-pin relay wiring The common 3-pin relay is the car horn relay. No. 1 is the contact terminal, which connects the load; No. 2 is the common terminal between the contact and the coil, which is connected to the power supply; No. 3 is the coil terminal, which connects the button switch (such as the horn on the steering wheel).

Peel magnetic relays – the difference between solid state relays and mechanical relays Peel magnetic relays – the difference between solid state relays and mechanical relays

1. The structure/working principle of the two is different Mechanical relays consist of an iron core, coils, and contacts. When the coil is energized, the current in the coil generates a magnetic field that makes the contacts act, thus completing the working principle of the mechanical relay. Solid state relays are made up entirely of electronic components. That...

Peel magnetic relay - the wiring method, function and application of time relay Peel magnetic relay - the wiring method, function and application of time relay

Wiring method of time relay 1. Control wiring You think of it as a DC relay. 3. 7 is used to connect to 12V control voltage; 2. 7 is used to connect to 24V control voltage. 7 of them are used as the negative electrode of direct current, which is connected to the neutral line when used. 2. Connect to a 220V live wire. 2 ...

Pilz: Don't underestimate the authorization key, it can make a big difference! Pilz: Don't underestimate the authorization key, it can make a big difference!

With the increasing functional requirements of industrial production, the continuous optimization of process levels and the escalation of the complexity of production conditions, systems that effectively record and manage relevant data are particularly important for machine safety, especially for production safety. PITreader Authorization ...

Pilz safety switches – wiring methods for safety switches Pilz safety switches – wiring methods for safety switches

1. The switch binding post is generally marked with L, L1, L2. When the L end enters the line, L1 and L2 have one end and L on, and after pressing the switch, the other end of L1 and L2 is connected to L. 2. Peel the thread with diagonal pliers first, and be careful not to leave too long the thread to avoid touching. 3. To the left ...

Peel magnetic relays – what do you need to do when equipping your machine with a safety light curtain? Peel magnetic relays – what do you need to do when equipping your machine with a safety light curtain?

1. Choose the correct encoder model 2. Build the right safety loop 3. There is no blind spot in the installation of safety light curtains 4. The safety distance of the safety light curtain meets the requirements of EN ISO 13855 ...

REASONS FOR USE OF PILZ SAFETY RELAYS REASONS FOR USE OF PILZ SAFETY RELAYS

Why can't ordinary relays be used in safety-related applications? Ordinary relays use the mechanical action of coils and metal contacts to switch loads. Metal contacts may be fusion welded due to repeated operations. Once this happens, the machine will also be ...

Pilz: New system version PSS 4000 1.24 Pilz: New system version PSS 4000 1.24

The automation system PSS 4000 offers new features in the new version 1.24. Here's what you need to know:   New data types FIXED and LFIXED The data types FIXED (a fixed digit with 6 decimal places) and LFIXED (a fixed number with 11 decimal places) are now ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top