1. GGD AC low-voltage distribution cabinet has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, seriality, strong practicability, novel structure and high protection level. It can be used as a replacement product for low-voltage switchgear.
Structural features
1. The cabinet body of the GGD AC low-voltage distribution cabinet adopts the form of a general cabinet, and the frame is assembled by local welding of 8MF cold-formed steel, and has 20 mold mounting holes, and the general coefficient is high.
2. The GGD cabinet fully considers the problem of heat dissipation. There are different numbers of heat dissipation slots at the upper and lower ends of the cabinet, when the electrical components in the cabinet are heated, the heat rises, and is discharged through the upper slots, and the cold air is continuously supplemented into the cabinet by the lower slots, so that the sealed cabinet body forms a natural ventilation channel from bottom to top to achieve the purpose of heat dissipation.
3. In accordance with the requirements of modern industrial product design, the GGD cabinet adopts the golden ratio method to design the shape of the cabinet and the segmentation size of each part, so that the whole cabinet is beautiful and generous, and has a new look
4. The top cover of the cabinet can be removed when needed, which is convenient for the assembly and adjustment of the main bus on site, and the four corners of the cabinet top are equipped with lifting rings for lifting and shipment.
5. The protection level of the cabinet is IP30, and the user can also choose between IP20 and IP40 according to the requirements of the environment.
2. GCK switchgear has high breaking capacity, good dynamic and thermal stability, advanced and reasonable structure, flexible electrical scheme, seriality, strong versatility, arbitrary combination of various scheme units, and a cabinet. It has the advantages of a large number of circuits, saving floor space, high protection level, safety and reliability, and convenient maintenance.
Structural features
1. The whole cabinet adopts an assembled combined structure, modular hole installation, strong versatility of parts, good applicability and high degree of standardization
2. The upper part of the cabinet is the bus room, the front part is the electrical room, and the rear part is the cable inlet and outlet room, and there are steel plates or insulating plates between the rooms to ensure safety.
3. The door of the drawer chamber of the MCC cabinet is equipped with a mechanical interlock with the operating handle of the circuit breaker or isolation switch, and the door can only be opened when the handle is in the broken position.
4. The drawer of the power receiving switch, contact switch and MCC cabinet has three positions: the connection position, the test position and the disconnection position.
5. The top of the switch cabinet can be installed with a bus bridge according to the needs of power reception.
|
More on that
|
Rittal cabinets – the difference between racks, cabinets, and servers?
1. a rack
Rack: Installed in a standard cabinet, it is a functional server, so the standard cabinet is also called a "19-inch" rack. Rack is a more professional academic term, and most of the current policy documents mention "rack", and clarify the indicators such as single rack power and average shelf rate ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
How is an electric current formed?
Answer: The free electrons in the conductor move regularly and directionally under the action of the electric field force, and an electric current is formed.
What are the indicators of power quality?
Answer: Voltage deviation, voltage fluctuation and flicker, voltage sine wave distortion rate, frequency deviation. ...
|
|
When winter arrives, Rittal heaters bring warmth to the cabinets
We know that electronic and electrical equipment is installed in the electrical cabinet, in fact, there are working temperature requirements, the general storage temperature can not be lower than minus 25 degrees, the working temperature can not be lower than minus 20 degrees, but now the outdoor temperature in the north is very simple to reach the lower limit of this working temperature, this time heating ...
|
|
Rittal cabinets – what are the installation specifications for the cabinets?
1. The host, storage equipment, and server cabinets should be partitioned and arranged, and the host, storage equipment, server cabinets, UPS power supplies, precision air conditioners and other equipment should be set aside for maintenance according to product requirements, and the maintenance interval overlaps with adjacent equipment;
2. Enter the equipment in the computer room in stages.
|
|
A detailed presentation of Rittal's new smart electronic lock
With the development of data centers in the direction of more intelligent and high reliability, the information stored in the servers in the IT cabinet is becoming more and more important, and the operation and maintenance of the data center needs to be able to manage the door opening of the cabinet more effectively to avoid server downtime caused by human factors.
Traditional Mechanical Cabinet Locks ...
|
|
Rittal cabinets – maintenance methods for low-voltage distribution cabinets
1. The purpose is to ensure the normal and safe operation of the low-voltage distribution cabinet and the control cabinet of each equipment.
Second, the scope is suitable for the low-voltage distribution room distribution cabinet, and the control cabinet of each equipment shall be implemented with reference to the relevant provisions according to the specific situation.
Third, the responsibility of the mechanical and electrical installation and maintenance engineering department maintenance team every six months ...
|
|
Common fault codes and handling methods for Rittal cabinet air conditioners
1. E0: Indoor temperature sensor is faulty. When this fault code appears, you need to check whether the indoor temperature sensor is working properly.
2. E1: Outdoor temperature sensor failure. When this fault code appears, you need to check whether the outdoor temperature sensor is working properly.
3. E2 ...
|
|
A detailed assortment of Rittal products
Rittal's products are: Rittal control cabinets: small cabinets (polycarbonate cabinets PK, junction boxes KL, compact control boxes EB, bus cabinets BG), compact control cabinets, plastic control cabinets KS, cabinet systems (subdivided into TS 8/SE 8 family), parallel cabinet systems...
|
|
Rittal Cables - Causes and countermeasures of line faults of power cables
External damage: In the process of storage, transportation, laying and operation of cables, they may suffer external damage, especially the directly buried cables that have been run, and are prone to damage in the ground construction of other projects. Such accidents often account for 50% of cable accidents. In order to avoid such accidents, in addition to strengthening the cable ...
|
|
Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets
1. Normal power transmission operation process of low-voltage distribution cabinet:
1. All load switches are disconnected, confirm that the switches have at least one breakpoint;
2. Confirm that the power switch is in the disconnected position;
3. Send the power supply to the operation circuit, and the status indication is normal;
4. The incoming switch is - isolated ...
|
|
What are Rittal cabinets used for?
1. The cabinet is generally made of cold-rolled steel plate or alloy to store the computer and related control equipment, which can provide protection for the storage equipment, shield electromagnetic interference, arrange the equipment in an orderly and neat manner, and facilitate the maintenance of the equipment in the future. Cabinets are generally divided into server cabinets, network machines, etc.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main technical parameters of the fuse?
Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage.
What are the main products of low-voltage power distribution equipment?
Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...
|
|
Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant
A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (11-20)
11. What is the definition and classification of secondary circuits?
Answer: The secondary circuit is used to monitor the measuring instrument, control the operation signal, all the low-voltage circuits of the relay and automatic devices are called the secondary circuit, and the secondary circuit can be divided into (1) current circuit according to the power supply and use; (2) Electricity ...
|
|
Rittal Nonwovens filter mats product description
Product Introduction
Product name: Rittal Rittal
Product Type: Rittal Non Woven Filter Mats
Product Model: 3172.105
Spare filter mats for top-mounted fans, filter fans or thermoelectric coolers to protect control cabinet components from dirt, ash ...
|
|
Rittal X SF | Helping smart logistics airports set sail safely
Hello, your courier has been sent out and will be delivered tomorrow morning.
Perfect logistics network, intelligent sorting, digital control ...... The development of modern logistics has made logistics services increasingly efficient and fast, and timely delivery and next-day delivery are no longer slogans.
|
|
Rittal cabinets – what are the characteristics of explosion-proof cabinets compared to ordinary cabinets?
1. It can be installed in places where dangerous gases exist, and it is safe to use the control cabinet in some environments with gas or vapor gas.
2. The shell of the control cabinet is generally made of steel plate welding or cast aluminum alloy die-casting, with high-voltage electrostatic spraying, and the whole is made of flameproof type.
|
|
Presentation of the features of the Rittal cabinet TS8 seismic kit
Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong.
|
|
Analysis of the interior of the Rittal cabinet TS8 series
RITTAL TS8 cabinet front door door rear sealing plate, a galvanized mounting plate 16-fold profile
ISV-TS 8 cabinets with a maximum current of 1600 A single door
Can be installed in all TS 8 cabinets of the same height and depth
- Can be pre-installed in configurations
- Available in the spirit ...
|
|
Rittal and Epan – the intelligent future of drive cabinet systems
"Promote the deep integration of the Internet, big data, and artificial intelligence with the real economy, and make the digital economy bigger and stronger." The new generation of information technology is accelerating the all-round and in-depth integration with the traditional manufacturing industry.
Rittal and Epan, with "digital twins" from virtual to real, help control cabinets and open ...
|
|