Analysis of the interior of the Rittal cabinet TS8 series

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

RITTAL TS8 cabinet front door door rear sealing plate, a galvanized mounting plate 16-fold profile

ISV-TS 8 cabinets with a maximum current of 1600 A single door

Can be installed in all TS 8 cabinets of the same height and depth

- Can be pre-installed in configurations

- Flexible installation of TS 8 cabinet interior accessories such as doors, locking systems, partial mounting plates and temperature control components

- Optional door hinges on the L/H or R/H side

- Components for mounting as input or output feeder panels upon request.

- The cable inlet and outlet can be freely selected according to the cabinet configuration

concentrate

- Depending on the cabinet selection, depending on the cabinet option, it will always be necessary to install contact protection modules with 4 height parts (600 mm) and 2 or 3 width parts (500 or 750 mm) at the inlet or outlet end.

- When using the Rittal NH Fused Load Switch Size 00 – 3, care should be taken to ensure that:

Always install a contact protection hazard module with at least 1 U (150 mm) in the NH load switch for thermal reasons.

- The contact protection module covering the NH belt in all directions needs to be processed by the customer.

Material/Surface Treatment

Material: Steel plate

Cabinet frame, top and rear plates, and bottom plate: 1.5 mm

Door: 2.0 mm

Protective frame against contact: Rigid PVC, RAL 9002

Surface Treatment:

Cabinet frame: Electrophoretic primer

Doors, top and rear panels: Electrophoretic primer, electrostatic powdered in colour RAL 7035, textured

Base plate: galvanized

Scope of supply

Modular frames for easy installation of cabinet frames, doors, top panels, rear panels, three-section base plates, and contact protection frames
Analysis of the interior of the Rittal cabinet TS8 series

More on that
Rittal Cabinet - Knowledge Q&A of High and Low Voltage Distribution Cabinet (21-30) Rittal Cabinet - Knowledge Q&A of High and Low Voltage Distribution Cabinet (21-30)

21. What does the workplace have to meet for high-voltage electrical appliances? Answer: A. Rated voltage, B. Maximum working voltage, C. Rated current, D. Rated short-circuit interrupting current, E. Short-time withstand current and peak withstand current. 22. What are the basic requirements for a high-voltage circuit breaker? Answer: A work ...

Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets

▲ GGD AC low-voltage distribution cabinet: (1) Use GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...

Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring

1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development; Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.

Rittal's new Maxi-PLS busbar system is launched! Rittal's new Maxi-PLS busbar system is launched!

In electrical switchgear, the external connection of high-current frame circuit breakers (ACBs) is usually achieved by connecting multiple cables per phase in parallel. When the conventional flat copper bar scheme is adopted, it is necessary to cut a number of bolt fastening holes on the standard copper bar to complete the connection of the cable.

Rittal cabinets – what are the characteristics of explosion-proof cabinets compared to ordinary cabinets? Rittal cabinets – what are the characteristics of explosion-proof cabinets compared to ordinary cabinets?

1. It can be installed in places where dangerous gases exist, and it is safe to use the control cabinet in some environments with gas or vapor gas. 2. The shell of the control cabinet is generally made of steel plate welding or cast aluminum alloy die-casting, with high-voltage electrostatic spraying, and the whole is made of flameproof type.

Rittal RBT side-mounted cooling unit cabinet air conditioning Rittal RBT side-mounted cooling unit cabinet air conditioning

Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production, as well as the excellent functions of the cooling unit itself, the RBT has achieved a very high ...

The Rittal TS8 system solution is designed to cope with extreme mining conditions The Rittal TS8 system solution is designed to cope with extreme mining conditions

Energy consumption planning continues to grow, and countries around the world have significantly increased the supply of low-carbon power such as nuclear, hydro, wind, and solar energy in order to achieve energy conservation and emission reduction. But now that natural resources are simply being exploited, what are the important developments of green energy that are lacking? The answer is: geothermal energy ...

What are the application areas of Rittal cabinets – cabinet air conditioners? What are the application areas of Rittal cabinets – cabinet air conditioners?

Indoor unit: suitable for all kinds of control boxes, distribution boxes and electrical cabinets in machinery, electric power, chemical industry, textile machinery, automation equipment, instrumentation and other industries with high requirements for temperature and humidity. It can also be used to regulate temperature and humidity in small spaces. Outdoor unit: suitable for outdoor general base station, outdoor ...

Rittal cabinets – judgment and handling of high-voltage switchgear closing faults Rittal cabinets – judgment and handling of high-voltage switchgear closing faults

Closing faults can be divided into electrical faults and mechanical faults. There are two types of closing methods: manual and electric. Failure to close manually is generally a mechanical failure. Manual can be closed, electric can not close is an electrical fault. 1. Protection action: The protection action has been analyzed in front to trip the switch. ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Power distribution circuits? Answer: From the regional substation to the substation of the electricity unit or the power supply line of the city and township, it is the line used to distribute electric energy. Power lines can be divided into according to the erection method? A: Overhead power lines and cable lines. ...

Precautions for the use of Rittal electrical cabinets Precautions for the use of Rittal electrical cabinets

1. When the electrical cabinet is used, the shell should be reliably grounded, and the electrical parts should be comprehensively inspected to eliminate the phenomenon of leakage and open circuit that may be caused by long-distance transportation, and check whether the voltage is consistent with the working voltage. 2. The electric cabinet is a non-explosion-proof oven, so it is flammable, explosive, volatile and corrosive.

Rittal Cables – precautions for the installation and wiring of control cables Rittal Cables – precautions for the installation and wiring of control cables

Precautions for the installation and wiring of control cables: 1. Under the eaves. Cables can only be used if they are not directly exposed to sunlight or ultra-high temperatures, and it is recommended to use pipes. Ultraviolet (UV) – Do not apply cables without UV protection to direct sunlight rings ...

Rittal cabinets – maintenance methods for motor control cabinets Rittal cabinets – maintenance methods for motor control cabinets

1. Disconnect the power supply, check whether the rack of the control cabinet has reliable grounding, and make the grounding resistance not greater than 4Ω. 2. There are voltages of different properties on the control cabinet (DC 110V; Communication single-phase 220V; Three-phase communication), the circuit must be distinguished during maintenance to avoid short-circuit accidents.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the basic requirements for a high-voltage circuit breaker? A: A. Reliable work; B. Have sufficient circuit breaking capacity C. Have the shortest possible cut-off time; D. Simple structure and low price. What is the purpose of the disconnector? Answer: A. Electrical...

Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant

A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...

The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder

Product Model 2485.100 Replace standard locks with or without a secure semicircular cylinder.   Type::C Color: RAL 9011 A note on the order number: Not suitable for AE 1018.600 Lock: Cylinder: No safety cylindrical cylinder ...

Rittal cables – type descriptions for power cables Rittal cables – type descriptions for power cables

The model of the power cable 1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...

Rittal cabinets – maintenance rules for network cabinets Rittal cabinets – maintenance rules for network cabinets

1. Once a month (8 hours at the end of the month), and make a maintenance record. 2. Clean the gears of the whole machine to ensure the cleanliness and normal clearance of the gears. 3. Check the gap between the two gears at the punching device of the processing department and adjust the clearance. 4. Adjust the gap between each ink roller to ensure that ...

Introducing the Rittal Product Configuration System (RiCS). Introducing the Rittal Product Configuration System (RiCS).

The Rittal Configurator (RiCS) is a new system configurator for the Rittal system product. It will allow you to quickly select a custom-configured cabinet that meets your application needs. During the configuration process, you can view the configuration in real time through the visual 3D model. After the configuration is complete ...

Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage

Reliable supply wherever you are Tesvolt's large-scale industrial battery storage systems are based on standard products made by Rittal and guarantee a continuous power supply on the top of a mountain, by the sea or in the desert. The mountain peaks rise high above the crystal clear ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top