Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong and together reduces its weight. This technology has been used with great success in the construction of houses, bridges and other load-bearing structures.
Rittal uses truss technology in the TS 8 series of enclosures, which makes them optimally shock-resistant. Introduced in 1999, this standard cabinet has sold more than 10 million units worldwide and is used in a wide range of occupations.
The cabinet is robust, unusually sensitive, efficient and of high quality. The TS 8 cabinet can be strengthened with an optional anti-vibration kit to meet the stringent Telcordia GR 63-CORE Zone 4 requirements.
The tie rods included in the 01 Seismic Kit can be screwed to the side of the cabinet structure, which greatly enhances the rigidity of the cabinet.
02 Reinforcement plates on the corners of the structure can add additional stability.
03The rigidity of the device plate is also better, and it can be connected to the tie rod through screws.
04The base used to secure the cabinet to the ground is also more secure for improved seismic resistance
TS 8 Standard Cabinet 8806.500 Combined with the corresponding height of 100mm TS steel plate base, the device plate has a load capacity of 152KG, which can meet the requirements of Seismic Zones 1, 2 and 3 according to Bell Labs.
|
More on that
|
How many fault codes does a Rittal cabinet air conditioner have?
There are a total of 9 fault codes for Rittal cabinet air conditioners,
They are: F1, F2, F3, FF, EH, EP, EL, SF, HC.
Among them, F1, F2, and F3 represent improper use or failure of internal components;
FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault;
E ...
|
|
Rittal's edge data centres inject new momentum into the digital development of enterprises
At the China International Information and Communication Exhibition (PT Exhibition) in Beijing, Rittal is showcasing its innovative "edge data center" solutions. In an era of increasing demand for high-speed processing and maximum flexibility, small, flexible edge data centers are digitizing enterprises in a steady stream of ...
|
|
Rittal at the Hannover Messe 2022 in Germany
"In 2022, with all the challenges, especially for small and medium-sized manufacturing companies – we need to think differently: if we want to support our customers and add value in our digital transformation, it's not just a single product innovation that will change. It will combine automation, digital ...
|
|
Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring
1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development;
Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.
|
|
Advantages of Rittal cabinets
1. Rittal cabinet can be divided into three series from the structure, ES cabinet (five-fold profile cabinet), PS cabinet (nine-fold profile cabinet), TS cabinet (sixteen-fold profile cabinet), the biggest feature is that the Rittal cabinet is the selection of profile structure structure, the structure of the cabinet is welded first, and then the top plate, bottom plate, side panel, door...
|
|
Rittal cabinets – how network cabinets are organized and maintained
1. Preparation
First of all, the user should be notified to organize the cabinet without affecting the normal operation of the user.
Then, according to the topology of the network, the existing equipment, the number of users, the user group and other factors, the wiring diagram and equipment inside the cabinet are outlined.
|
|
Rittal cabinets – what are the installation specifications for the cabinets?
1. The host, storage equipment, and server cabinets should be partitioned and arranged, and the host, storage equipment, server cabinets, UPS power supplies, precision air conditioners and other equipment should be set aside for maintenance according to product requirements, and the maintenance interval overlaps with adjacent equipment;
2. Enter the equipment in the computer room in stages.
|
|
Rittal cabinets – the characteristics of GDD and GCK low-voltage distribution cabinets
1. GGD AC low-voltage distribution cabinet has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, seriality, strong practicability, novel structure and high protection level. It can be used as a replacement product for low-voltage switchgear.
Structural features
...
|
|
Rittal cables – the common code for cables
Usage code - not marked as power cable, K- (control cable), P- (signal cable);
Conductor material code - not marked as copper (can also be marked as CU), L- (aluminum);
Inner Sheath Code – Q-(Lead Packed), L- (Aluminum Cladding), H- (Rubber Jacket), V-(Polyvinyl Chloride ...
|
|
Rittal Cables – the operation of power cable routes
The operating voltage of the cable
Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. When the neutral point is not grounded ...
|
|
Rittal Cabinet - Knowledge Quiz of High and Low Voltage Distribution Cabinet (51-60)
51 What are the factors that affect the degree of harm to the human body caused by electric shock?
Answer: Factors such as the magnitude of the current, the duration of the current, the path of the current, the resistance of the human body and the frequency of the current.
52 Types of electric shock?
Answer: Direct electric shock, indirect electric contact, inductive ...
|
|
Rittal enclosures – operating precautions for low-voltage distribution cabinets
First, set posts and responsibilities. The power department of distribution box equipment should number, register, file, hierarchical management, clear responsibilities, and regularly carry out technical inspection and maintenance of the distribution box.
|
|
What are the main classifications of Rittal cables – power cables?
Classified by voltage level
According to the voltage level, it can be divided into medium and low voltage power cables (35 thousand volts and below), high-voltage cables (above 110 thousand volts), ultra-high voltage cables (275-800 thousand volts) and ultra-high voltage cables (1000 thousand volts and above). In addition, it can also be divided into AC ...
|
|
Rittal RBT side-mounted cooling unit cabinet air conditioning
Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production, as well as the excellent functions of the cooling unit itself, the RBT has achieved a very high ...
|
|
Rittal cabinets – what electrical components are included in the electrical cabinet?
1 Circuit breaker
Low-voltage circuit breakers, also known as automatic air switches, can be switched on and off manually, and can be used to distribute electrical energy, start asynchronous motors infrequently, and protect power lines and motors. In the event of a severe overload, short circuit, or undervoltage fault, the circuit can be automatically shut down.
2 Contactors
...
|
|
Rittal Cables – an introduction to the performance of industrial control cables
Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.
|
|
Rittal presents its modular data centre solutions
Now AI has been widely used in many fields, and while we enjoy the convenience brought by AI skills, we should also know that behind these AI skills are a huge amount of data processing and communication by weak servers, and then find the most efficient solutions.
|
|
Rittal cabinets - judgment and handling of common faults in high-voltage switchgear
1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation
1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature.
2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...
|
|
Rittal cables – type descriptions for power cables
The model of the power cable
1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...
|
|
The Rittal SE 8 system cabinet shows you what efficiency looks like
SE 8 system cabinet
Lightweight, yet still strong
Industry applications are becoming increasingly complex, and there is a demand for low-complexity cabinet systems for efficient assembly in all industry applications. To meet the needs of the market, Rittal has launched the new SE8 freestanding enclosure.
...
|
|