Rittal Nonwovens filter mats product description

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

Product Introduction

Product name: Rittal Rittal

Product Type: Rittal Non Woven Filter Mats

Product Model: 3172.105

Spare filter mats for top-mounted fans, filter fans, or thermoelectric coolers to protect control cabinet components from dirt, dust, and water.

Type: For filter fan

Product description: Non-woven fibers with a multi-layer structure, temperature resistance up to 100 °C, flame retardancy class F1 according to DIN 53 438. Dusty air side: Open structure. Pure air side: Closed structure. It reliably reliably reliably removes almost all dust particles with a particle size of more than 10 μm.

Material: Chemical fiber

Note: Only when used in combination with original Rittal filter mats can the power parameters, degree of protection and permissible values of the system be ensured.

Matching model: 3240....

  3241....

Dimensions: Width: 221 mm

Height: 221 mm

Depth: 17 mm

Filtration class: according to DIN EN 779: G3

According to DIN EN ISO 16890: ISO Coarse 50%

Weight / Package: 0.7 kg
Rittal Nonwovens filter mats product description

More on that
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the basic requirements for a high-voltage circuit breaker? A: A. Reliable work; B. Have sufficient circuit breaking capacity C. Have the shortest possible cut-off time; D. Simple structure and low price. What is the purpose of the disconnector? Answer: A. Electrical...

Rittal RBT side-mounted cooling unit cabinet air conditioning Rittal RBT side-mounted cooling unit cabinet air conditioning

Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production, as well as the excellent functions of the cooling unit itself, the RBT has achieved a very high ...

Common fault codes and handling methods for Rittal cabinet air conditioners Common fault codes and handling methods for Rittal cabinet air conditioners

1. E0: Indoor temperature sensor is faulty. When this fault code appears, you need to check whether the indoor temperature sensor is working properly. 2. E1: Outdoor temperature sensor failure. When this fault code appears, you need to check whether the outdoor temperature sensor is working properly. 3. E2 ...

Causes and solutions of low-voltage distribution cabinet alarms Causes and solutions of low-voltage distribution cabinet alarms

1. It is not displayed at that time. Solution: Check whether the sample signal cable is not connected. 2. Whether the fuse core of the controller in the cabinet is burned out. Solution: Remove the burned out fuse core and replace it with a new one. 3. The voltage of the distribution cabinet is too high, and the overvoltage alarm. Workaround: Re...

Rittal and Epan – the intelligent future of drive cabinet systems Rittal and Epan – the intelligent future of drive cabinet systems

"Promote the deep integration of the Internet, big data, and artificial intelligence with the real economy, and make the digital economy bigger and stronger." The new generation of information technology is accelerating the all-round and in-depth integration with the traditional manufacturing industry. Rittal and Epan, with "digital twins" from virtual to real, help control cabinets and open ...

Rittal cabinet - the introduction and function of network cabinets Rittal cabinet - the introduction and function of network cabinets

What is a Network Cabinet? The network cabinet is a kind of rectangular cabinet composed of two parts: frame and cover, which can install switches, optical fiber adapters, optical fiber distribution frames and other equipment in a cabinet, with electromagnetic barrier, noise blocking, ventilation and heat dissipation, anti-vibration, anti-corrosion, etc.

How to set the temperature of the Rittal air conditioner How to set the temperature of the Rittal air conditioner

1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters. 2. High temperature alarm: ...

What is the daily maintenance method of the air conditioner? - Rittal air conditioning What is the daily maintenance method of the air conditioner? - Rittal air conditioning

1. Filter maintenance of the indoor unit: The filter screen of the indoor unit generally needs to be replaced once every two months. It is not recommended to continue to use it after rinsing, because the rinsed filter is easy to stick, so that ventilation and ventilation are not smooth, and air circulation is affected. So if it's a one-off, direct replacement, not ...

Rittal supports its customers with food safety testing Rittal supports its customers with food safety testing

With the continuous improvement of people's living standards, more delicacies continue to flock to the market to satisfy the taste buds of foodies. However, is the food that is about to be delivered to your mouth really healthy? How to ensure the food safety and health of the tip of the tongue without foreign substances? People are concerned about the quality and safety of food production, testing, and safety.

Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures

1. Avoid light The server is required to operate in a constant temperature environment, and direct sunlight will increase the temperature in the computer room, which will damage the display and shorten its service life. When operating in IDC and ISP data centers, it is impossible to see a ray of sunshine. So, in ...

The Rittal SE 8 system cabinet shows you what efficiency looks like The Rittal SE 8 system cabinet shows you what efficiency looks like

SE 8 system cabinet Lightweight, yet still strong Industry applications are becoming increasingly complex, and there is a demand for low-complexity cabinet systems for efficient assembly in all industry applications. To meet the needs of the market, Rittal has launched the new SE8 freestanding enclosure. ...

Rittal cabinet - judgment and treatment of sudden trip fault in operation of high-voltage switchgear Rittal cabinet - judgment and treatment of sudden trip fault in operation of high-voltage switchgear

1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature. 2) Judgment method: The cause of the fault can be judged according to the relay card drop, remote signaling information, etc. After the action of gas and temperature protection in the high-voltage cabinet ...

The Rittal RiEDC series has been named the IT Solution of the Year 168 The Rittal RiEDC series has been named the IT Solution of the Year 168

The Rittal RiEDC series has been awarded Solution of the Year at the IT168 Technical Excellence Awards. The "Technical Excellence Award" is jointly judged by professional users of the big data industry, technical experts and the media, and its criteria are based on innovative solutions recognized by the market and customers, ...

Rittal cables support factory assembly and cabling Rittal cables support factory assembly and cabling

Imagine you walk into a large, well-maintained room with many cabinets and mounting plates waiting to be machined. Several staff members focus on assembly and wiring work. Another thing that will surprise you is the complete absence of paper – no folders crammed with circuit diagrams, and no work orders. This ...

Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50) Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)

41. Can power lines be divided into according to the erection method? A: Overhead power lines and cable lines. 42 What is a protective relay? Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...

Rittal cabinets – what are the common cabinet cable management processes? Rittal cabinets – what are the common cabinet cable management processes?

First, the waterfall shape This is one of the older wiring patterns that can sometimes be seen. It adopts the artistic image of "Huaguo Mountain Water Curtain Cave", and directly hangs the twisted pair from the module of the patch panel, and there is a very beautiful sense of hierarchy when it is neatly distributed (24-48 per layer).

Some precautions should be taken in the installation and setting of Rittal air conditioning Some precautions should be taken in the installation and setting of Rittal air conditioning

The arrangement of the electronics in the cabinet Note: Condensation is dangerous! When the electronics are arranged in a Rittal cabinet, the cold air from the air conditioner must not flow directly to the live device. Cold air must not be allowed to flow directly to a hot exhaust gas stream from a live device such as a frequency converter. Because this will lead to ...

Advantages of Rittal cabinets Advantages of Rittal cabinets

1. Rittal cabinet can be divided into three series from the structure, ES cabinet (five-fold profile cabinet), PS cabinet (nine-fold profile cabinet), TS cabinet (sixteen-fold profile cabinet), the biggest feature is that the Rittal cabinet is the selection of profile structure structure, the structure of the cabinet is welded first, and then the top plate, bottom plate, side panel, door...

Cable management components for Rittal's IT cabinets Cable management components for Rittal's IT cabinets

An IT cabinet generally needs to arrange a lot of cables, including strong current cables for power supply equipment, optical fibers used for communication, and weak current cables for signal transmission. So many cables in a cabinet if not well packed up form a clutter of cables in the cabinet, and then ...

The Rittal TS8 system solution is designed to cope with extreme mining conditions The Rittal TS8 system solution is designed to cope with extreme mining conditions

Energy consumption planning continues to grow, and countries around the world have significantly increased the supply of low-carbon power such as nuclear, hydro, wind, and solar energy in order to achieve energy conservation and emission reduction. But now that natural resources are simply being exploited, what are the important developments of green energy that are lacking? The answer is: geothermal energy ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top