"Promote the deep integration of the Internet, big data, and artificial intelligence with the real economy, and make the digital economy bigger and stronger." The new generation of information technology is accelerating the all-round and in-depth integration with the traditional manufacturing industry.
Rittal and E-Pan use "digital twins" from virtual to reality to help the sustainable development of control cabinets and switchgears, serve all walks of life, and drive the intelligent future of cabinet systems.
Under the national intelligent manufacturing strategy, the development process of digitalization, networking and intelligence in the manufacturing industry has accelerated, and a large number of data interactions have posed challenges to the response and storage of data in the manufacturing industry. At the same time, Rittal provides IT edge data center and large data center solutions, which "intelligently interconnect" the real-time data required for factory-level smart manufacturing, where it can be quickly processed and analyzed to the cloud, forming a closed loop for access and use in the smart manufacturing process. Several exhibition areas with the theme of "intelligence" at the CIIF are interpreting Rittal's innovative practice in "intelligence and interconnection":
Smart cities facilitate life
Smart cities encompass everything from power distribution, transportation systems, street lighting to even garbage collection, water utilities, and more. Rittal is using data and technology to improve efficiency, save resources and make life easier and better in the city.
Smart industry is solid
Intelligent industry is a new industrial system that integrates hardware equipment, information network and human brain intelligence. Rittal implements it everywhere in all walks of life.
The edge of Zhirong is close at hand
The centralized computing processing model will face difficult bottlenecks, and the edge computing model may become an effective solution. Rittal's "Edge Data Center + High Performance Computing Solution" provides edge intelligence services at the edge of the network close to the source of things or data to meet the key needs of industry digitalization in terms of agile connectivity, real-time services, data optimization, application intelligence, security and privacy protection.
"Digital twins" achieve intelligent manufacturing
In the Rittal value chain system, from the engineering design of E-Pan Software to the manufacturing and processing of the "Rittal Automation System", to the final delivery, the "software + hardware + service" Rittal value chain system runs through the entire link of intelligent manufacturing of electrical cabinets, pushing "intelligent manufacturing" to another peak of wisdom.
Different from the past, during the exhibition, we brought rich activities such as online and offline forums, president goods, live broadcast booth innovation tour, exhibits photo collection and win awards, etc., and deeply interacted with the professional audience on the spot, injecting the power of intelligent manufacturing into the soul of every industrial person.
"Change is common, and change is long". Digital transformation is imperative, and Rittal and Epan will always be "customer-centric" to promote the improvement of digital manufacturing.
|
More on that
|
Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation
Sincere service, strength and responsibility
In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...
|
|
Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant
A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...
|
|
Rittal cabinets - judgment and handling of common faults in high-voltage switchgear
1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation
1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature.
2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...
|
|
What are the common cable management methods for Rittal cabinets – network cabinets?
1. The network cabinet distribution frame is fixed in place, the panel paper is loaded into the distribution frame on the front, and the tray is installed on the back.
2. Positioning of the cable management board, the direction of the cable management board should be determined before threading when positioning the cable management board, so that the cable management board does not need to twist the direction in the process of line management, and it can enter the ...
|
|
The solution to the A17 fault reported by the Rittal cabinet air conditioner
1. The Rittal air conditioner does not start when it is turned on, and the A17 is faulty.
Check that the power supply voltage is 220V, normal; Detect that the battery voltage of the remote control is 3V, which is normal; Measure the fuse resistance value of the air conditioner compressor with a multimeter as infinity, which is normal.
2. The Rittal air conditioner does not start when it is turned on, and the display is not started.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the conditions that must be met for high-voltage appliances?
A: A. The insulation is safe and reliable;
B. Long-term operation under rated current and certain short-term overload capacity;
C. Able to carry the thermal and electrodynamic effects of short-circuit currents without damage;
D. Switching electrical appliances can be safe...
|
|
Rittal cabinets – maintenance rules for network cabinets
1. Once a month (8 hours at the end of the month), and make a maintenance record.
2. Clean the gears of the whole machine to ensure the cleanliness and normal clearance of the gears.
3. Check the gap between the two gears at the punching device of the processing department and adjust the clearance.
4. Adjust the gap between each ink roller to ensure that ...
|
|
Rittal takes you through the efficient and accurate configuration of your enclosure system
In the recent Winter Olympics, short track speed skating star Wang Meng helped lock the first gold medal of the Chinese team in the Winter Olympics in advance with "My eyes are rulers". So what is the "magic weapon" that can help engineers refine the "sharp eye" of error-free assembly in the assembly of Rittal cabinet systems? ...
|
|
Rittal cables – safety requirements for cables
1. When the cables cross each other, the high-voltage cable should be below the low-voltage cable. If one of the cables is protected by a pipe or separated by a partition within 1m before and after the intersection, the minimum allowable distance is 0.25m.
2. When the cable is close to or crosses the thermal pipeline, if there are thermal insulation measures, the flat ...
|
|
Rittal cables – classified according to the purpose of the cable and the environment in which it will be used
1. DC cable
(1) Tandem cables between components.
(2) Parallel cables between strings and between strings and DC distribution boxes (combiner boxes).
(3) The cable between the DC distribution box and the inverter.
The above cables are all DC cables, outdoor laying ...
|
|
For the first time, the Rittal Rittal and Circle B and Switch data centres have launched the European OCP Experience Centre
Circle B, Rittal and Switch data centres in Germany launch the first European Open Computing Project (OCP) Experience Centre. The full-featured OCP environment is located at one of the facilities of three switching data centers in the Amsterdam area. (The OCP Experience Center can be used as a demo center, but it is also ...
|
|
Rittal's enclosure – seven common faults in the distribution cabinet and their failure analysis
1. The circuit breaker cannot be closed
Causes:
1. The undervoltage coil does not work (the voltage is normal). Solution: Replace the undervoltage coil.
2. Press the closing button, and the closing coil will not work when it is powered up. Solution: Replace the undervoltage coil.
3. Cooperation...
|
|
The Rittal TS8 system solution is designed to cope with extreme mining conditions
Energy consumption planning continues to grow, and countries around the world have significantly increased the supply of low-carbon power such as nuclear, hydro, wind, and solar energy in order to achieve energy conservation and emission reduction. But now that natural resources are simply being exploited, what are the important developments of green energy that are lacking? The answer is: geothermal energy ...
|
|
What are the functions on the operation panel of the inverter control cabinet?
Display parameters: The control panel can display various parameters of the inverter, such as input/output voltage, current, frequency, speed, etc.
Parameter setting: The control panel can set various parameters of the inverter, such as operating mode, frequency range, acceleration time, deceleration time, etc.
...
|
|
Common faults and solutions for Rittal cabinet air conditioners
If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start;
Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high.
The voltage of the air conditioner is unstable, and the compressor cannot be started normally.
|
|
How to set the temperature of the Rittal air conditioner
1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters.
2. High temperature alarm: ...
|
|
Rittal cabinets – the composition and function of low-voltage distribution cabinets
The power distribution panel is mainly composed of incoming cabinets, outgoing cabinets, capacitor cabinets, metering cabinets, etc.
Incoming cabinet: also known as the receiving cabinet, is a device used to receive electrical energy from the power grid (from the incoming line to the busbar), generally installed with circuit breakers, CT, PT, isolation knives and other components.
Outlet cabinet: ...
|
|
Rittal cables – the key point of TPE technology in wire and cable
1. TPE material has soft touch, high elasticity, mild texture, adjustable surface gloss and fog brightness, low smoke and halogen-free, phosphorus-free, excellent oil resistance, weather resistance, aging resistance, flex resistance, ozone resistance and chemical resistance.
2. The old TPE material can be simply recycled and recycled.
|
|
Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets
What is Arc?
Arc is a physical phenomenon generated during the operation of electrical equipment, which is characterized by very strong light and high temperature.
Classification of electrical loads?
Primary load: those whose power supply interruption will cause personal injury or death; or those that will cause significant losses politically or economically.
...
|
|
With the Rittal VX SE freestanding cabinet, the possibilities are endless
How to make it simpler?
How can safety be paramount?
Still worried about not being able to reduce the cost of the system?
The most suitable cabinet system is just a dream?
You've got you covered – faster, safer, simpler, compatible, and versatile...
|
|