With the development of data centers in the direction of more intelligent and high reliability, the information stored in the servers in the IT cabinet is becoming more and more important, and the operation and maintenance of the data center needs to be able to manage the door opening of the cabinet more effectively to avoid server downtime caused by human factors.
Traditional mechanical cabinet locks are completely dependent on keys, and the security, real-time, and recording performance are not high. In this regard, Rittal has launched a new type of intelligent electronic lock, which adopts excellent mechanical processing technology, high-quality electronic components, stable built-in software, radio frequency technology, network communication technology, etc., which can realize the functions of mechanical key, password, fingerprint, card swiping, and remote door opening and closing.
Features of Rittal's new smart electronic lock
The smart lock is mainly composed of the following three parts:
In-line comfort handle
01. Realize the function of remote control and access management by connecting CMC III or IOT interface
02. The built-in RBG indicator light displays the handle switch status in real time
03. It can be connected to a card reader or password disk for switch control
04. In case of emergency, the door can be opened by mechanical key
Cipher disk and card reader
01. The password disk can be set with a personalized numeric code, up to 8 digits
02. The card reader can support Mifare, Legic Advant, HID, FeliCa RFID cards
03Direct connection to CMC III access control module or CMC III gating module
04. Optical (LED) and acoustic (alarm tone) status display
05. Manage permissions through CMC III system, IoT communication module or RiZone (DCIM system).
06. Open the door through up to two linkage numeric codes (four-eyes principle)
CMC III Access Control Unit
01. Log all user information and time points for entering and opening doors
02. The handle and the card reader or cipher disk can be connected to the module at the same time
03. Cross-system and cross-site access rights management can be carried out through RiZone (DCIM system).
04. Control the LED display in the electronic handle
05. The built-in infrared sensor monitors the opening and closing status of the door in real time
|
More on that
|
Rittal Cables – the principle of selection of power cables
1. Selection of wire and cable models
When selecting wires and cables, it is necessary to consider the use, laying conditions and safety; For example, depending on the application, power cables, overhead insulated cables, control cables, etc. can be selected
According to the different laying conditions, the general plastic insulated cable can be selected ...
|
|
With the Rittal VX SE freestanding cabinet, the possibilities are endless
How to make it simpler?
How can safety be paramount?
Still worried about not being able to reduce the cost of the system?
The most suitable cabinet system is just a dream?
You've got you covered – faster, safer, simpler, compatible, and versatile...
|
|
Rittal RBT side-mounted cooling unit cabinet air conditioning
Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production, as well as the excellent functions of the cooling unit itself, the RBT has achieved a very high ...
|
|
How to set the temperature of the Rittal air conditioner
1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters.
2. High temperature alarm: ...
|
|
Rittal Cables – an introduction to the performance of industrial control cables
Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.
|
|
Rittal Cabinet - Knowledge Q&A of High and Low Voltage Distribution Cabinet (21-30)
21. What does the workplace have to meet for high-voltage electrical appliances?
Answer: A. Rated voltage, B. Maximum working voltage, C. Rated current, D. Rated short-circuit interrupting current, E. Short-time withstand current and peak withstand current.
22. What are the basic requirements for a high-voltage circuit breaker?
Answer: A work ...
|
|
How do two Rittal cabinets fit together?
1. The power cords of the two cabinets are connected to the power socket at the rear of the cabinet.
2. The RS232 interface of the two cabinets is connected together with a communication cable.
3. Lock the door of the main cabinet, and turn on the power from the cabinet and the main cabinet in turn.
...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)
41. Can power lines be divided into according to the erection method?
A: Overhead power lines and cable lines.
42 What is a protective relay?
Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...
|
|
What are the classifications of Rittal cabinets? What is the difference with a general cabinet?
1. What are the classifications of Rittal cabinets?
1. According to the function, it can be divided into: fireproof and anti-magnetic cabinet, power cabinet, monitoring cabinet, shielding cabinet, safety cabinet, waterproof cabinet, safe, multimedia console, file cabinet, wall-mounted cabinet.
2. According to the scope of application, it can be divided into: outdoor cabinets, ...
|
|
How many fault codes does a Rittal cabinet air conditioner have?
There are a total of 9 fault codes for Rittal cabinet air conditioners,
They are: F1, F2, F3, FF, EH, EP, EL, SF, HC.
Among them, F1, F2, and F3 represent improper use or failure of internal components;
FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault;
E ...
|
|
Rittal Cables – an introduction to the advantages of industrial control cables
1. It can meet the needs of many electrical appliances, and relatively speaking, in the process of making industrial control cables, the relevant standards of various information in the process of dissemination are fully considered. In this way, it can ensure that the industrial control cable can meet the performance of many electrical appliances in daily work.
|
|
Rittal cabinet fittings Rittal stainless steel rain cover for AE model 2472.000
Stainless steel rain top cover for AE
Product model 2472.000
Outdoor fixtures are safely and reliably protected with a drain channel at the back. Material: Stainless steel 1.4301 (AISI 304).
Product Description: Safe and reliable protection for outdoor installations, with ...
|
|
Rittal enclosures – considerations for control cabinet transfers
First, the assembly process
The assembly process is the guarantee of the assembly work, because only the assembly according to the process can ensure the quality of the assembly work. The process is the standard and requirement of assembly, and only the assembly according to the process can ensure the safety of assembly. However, before the assembly, the technical ...
|
|
The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder
Product Model 2485.100
Replace standard locks with or without a secure semicircular cylinder.
Type::C
Color: RAL 9011
A note on the order number: Not suitable for AE 1018.600
Lock: Cylinder: No safety cylindrical cylinder
...
|
|
How do Rittal cabinets be combined?
1. The power cords of the two cabinets are connected to the power socket at the rear of the cabinet.
2. The RS232 interface of the two cabinets is connected together with a communication cable.
3. Lock the door of the main cabinet, and turn on the power from the cabinet and the main cabinet in turn.
...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (1-10)
1. What is TT, IN, IT system?
A: The TT method refers to a protection system that directly grounds the metal shell of electrical equipment, which is called a protective grounding system, also known as a TT system. The TN method is a protection system that connects the metal shell of the electrical equipment with the working neutral line, called ...
|
|
Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation
Sincere service, strength and responsibility
In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...
|
|
Rittal presents a number of green and innovative sanitary cabinets at CBST
On April 7, 2023, the 11th CBST China International Beverage Industry Technology Exhibition was grandly held at the Shanghai New International Expo Center.
As a practitioner of the concept of "intelligent manufacturing" in Germany, Rittal brings many green and innovative sanitary cabinet systems and temperature control solutions.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What to do if you notice someone electrocuted?
Answer: First of all, make the electrocuted person quickly disconnect from the power supply. Its method, for low-voltage electric shock, can be used "pull", "cut", "pick", "pull", "pad" method, pull or cut off the power supply, the operation should pay attention to avoid people rescue people electric shock, should ...
|
|
Rittal Cables – What are the causes of faults in wires and cables?
1. External force damage. Judging from the operation analysis in recent years, especially in Haipu East, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in civil engineering on directly buried cables ...
|
|