Rittal cabinets – what are the installation specifications for the cabinets?

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

1. The host, storage equipment, and server cabinets should be partitioned and arranged, and the host, storage equipment, server cabinets, UPS power supplies, precision air conditioners and other equipment should be set aside for maintenance according to product requirements, and the maintenance interval overlaps with adjacent equipment;

2. Reasonably plan the equipment entering the computer room in stages, and reserve the corresponding position for it, which should not only conform to the process flow of the computer system, but also facilitate the future expansion positioning and cable connection of the expansion equipment;

3. When placing server cabinets with large heat generation, such as IBM690 and 670, the net distance between the front of the cabinet should not be less than 2.1 meters, so as not to affect the heat dissipation of the equipment due to excessive heat density;

4. In the server room with more equipment, it is recommended to use the column head cabinet method, and concentrate the integrated wiring cables in the column head cabinet instead of the core cabinet, which can save twisted pair and optical fiber.
Rittal cabinets – what are the installation specifications for the cabinets?

More on that
Rittal! Guarding the cabinet system with a "core". Rittal! Guarding the cabinet system with a "core".

As the "guardian" of the cabinet, the lock system is also an important accessory choice in the cabinet system. Locking systems include fasteners, locks, keys, handles, and cylinders, among others. The lock cylinder refers to the module that is replaced for different locks and keys. 01. Personalized configuration ...

Rittal precision power distribution cabinet SPDR - make the data center "feel safe". Rittal precision power distribution cabinet SPDR - make the data center "feel safe".

The power supply and distribution system of the data center is a system that provides stable and reliable power supply support for all the equipment that needs power supply in the computer room. The power supply and distribution system is like the heart of the human body for the entire data center system, and its importance is self-evident.   With the continuous construction of the network ...

What do you need to pay attention to when grounding the electrical control cabinet? What do you need to pay attention to when grounding the electrical control cabinet?

1. Make sure that all equipment in the electrical control cabinet is well grounded, and use short and thick grounding wires to connect to the common grounding point or grounding busbar. Any control equipment connected to the inverter should be co-grounded with it, and likewise ground with short and thick wires; 2. Flat conductors are used, e.g. ...

Rittal Cables – What do you need to pay attention to when wiring industrial control cables? Rittal Cables – What do you need to pay attention to when wiring industrial control cables?

1. The weight of the cable in the industrial control cable drag chain should be evenly distributed, so as to avoid accidents caused by uneven weight during operation, and the principle of distributing the cable is that the heavier one is located on both sides and the lighter one is located in the middle. All industrial control cables must be securely fastened to one end of the energy chain, so that ...

To help industrial upgrading with ingenuity and quality, Rittal and liquor companies talk about smart brewing To help industrial upgrading with ingenuity and quality, Rittal and liquor companies talk about smart brewing

China has a long history of winemaking. "Shuo Wen Jie Zi" once said: The ancients Yi Di made wine mash, Yu tasted it and was beautiful, so Yi Di was sparse. Du Kang made rice wine. Counting from the Yu period, liquor has a history of more than five or six thousand years in China, it is not only the inheritance of good taste, but also the long history of the Chinese nation.

Rittal cabinets – an introduction to the installation steps and features of the control cabinet Rittal cabinets – an introduction to the installation steps and features of the control cabinet

The control cabinet is according to the requirements of electrical wiring to assemble switchgear, measuring appearance, maintenance appliances and auxiliary equipment in a closed or semi-closed metal cabinet or screen panel, and its arrangement should meet the requirements of the normal operation of the power system, easy to overhaul, and not to endanger the safety of people and surrounding equipment. Normal operation ...

Alarm code causes and diagnostic methods for Rittal cabinet air conditioners Alarm code causes and diagnostic methods for Rittal cabinet air conditioners

Alarm code: A01 System message: Open the cabinet door The cause of the Rittal air conditioner: the opening and closing of the door is not in the correct position Diagnostic method: Check the changing position of the door and, if necessary, the connection status Alarm code: A02 System message: The temperature in the cabinet is too high ...

Some precautions should be taken in the installation and setting of Rittal air conditioning Some precautions should be taken in the installation and setting of Rittal air conditioning

The arrangement of the electronics in the cabinet Note: Condensation is dangerous! When the electronics are arranged in a Rittal cabinet, the cold air from the air conditioner must not flow directly to the live device. Cold air must not be allowed to flow directly to a hot exhaust gas stream from a live device such as a frequency converter. Because this will lead to ...

Rittal cabinets – what do you need to pay attention to when tidying up your cabinets? Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?

1. In principle, the power cord and network cable of the cabinet should be sorted out separately; 2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other; 3. If there are too many devices in the cabinet, the equipment should be numbered; 4. For each line ...

Rittal Cables – the main classification of wires and cables Rittal Cables – the main classification of wires and cables

Bare wire body products The main characteristics of this type of products are: pure conductor metal, no insulation and sheath layer, such as steel core aluminum stranded wire, copper-aluminum busbar, electric locomotive line, etc.; The processing technology is mainly pressure processing, such as smelting, calendering, drawing, stranding/pressing stranding, etc.; The main products ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How many types of protection devices are there for transformers? A: Overcurrent protection, current quick break protection, differential protection and gas protection. What are the requirements for relay protection? Answer: In order to be able to remove the fault correctly and quickly, it is required that the relay protection has sufficient selectivity ...

Rittal cabinets – daily maintenance methods for high and low voltage distribution cabinets Rittal cabinets – daily maintenance methods for high and low voltage distribution cabinets

Complete set of electrical maintenance knowledge: 1. Low-voltage distribution cabinet 1. Regularly check whether there are traces of pest activity in each cabinet, and carry out trapping regularly. 2. Check whether the warning signs and maintenance signs are placed correctly. 3. Check whether the emergency tools and lamps are in order.

An introduction to the features of Rittal cabinet fans An introduction to the features of Rittal cabinet fans

Wide air volume range: 20-900m3/h Innovative diagonal flow fan and brushless DC EC motor technology for higher air flow and uniform distribution of cold air Comes with an interface module for controlling and monitoring fans The standard degree of protection is IP54, up to IP56 with a water spray cover ...

Rittal Cables – an introduction to the advantages of industrial control cables Rittal Cables – an introduction to the advantages of industrial control cables

Fulfillment of the requirements of many electrical appliances: In the manufacture of industrial control cables, the relevant standards for the transmission of various information are fully considered. This ensures that the industrial control cables can meet the performance requirements of many electrical appliances in their daily work. Abrasion Resistance: Industrial Control ...

Rittal enclosures – considerations for control cabinet transfers Rittal enclosures – considerations for control cabinet transfers

First, the assembly process The assembly process is the guarantee of the assembly work, because only the assembly according to the process can ensure the quality of the assembly work. The process is the standard and requirement of assembly, and only the assembly according to the process can ensure the safety of assembly. However, before the assembly, the technical ...

Rittal cables – safety requirements for cables Rittal cables – safety requirements for cables

1. When the cables cross each other, the high-voltage cable should be below the low-voltage cable. If one of the cables is protected by a pipe or separated by a partition within 1m before and after the intersection, the minimum allowable distance is 0.25m. 2. When the cable is close to or crosses the thermal pipeline, if there are thermal insulation measures, the flat ...

Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant

A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...

What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure? What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure?

1. Safety: As the carrier of electrical equipment, the outdoor cabinet must have excellent structural design, solid materials, and firm bottom fixation to meet the requirements of strong typhoons, strong rainstorms, and even strong earthquakes. At the same time, the cabinet should have anti-leakage, anti-short circuit, anti-cut and other requirements. 2. Rainproof and dustproof ...

Rittal enclosures – operating precautions for low-voltage distribution cabinets Rittal enclosures – operating precautions for low-voltage distribution cabinets

First, set posts and responsibilities. The power department of distribution box equipment should number, register, file, hierarchical management, clear responsibilities, and regularly carry out technical inspection and maintenance of the distribution box.

Analysis of the causes of the alarm code of the Rittal cabinet and how to deal with it Analysis of the causes of the alarm code of the Rittal cabinet and how to deal with it

A01--- Rittal cabinet control cabinet door opens View: Look at the door switches in the Rittal cabinet. Solution: (1) Adjust the position of the door switch. (2) Check whether the wiring method is correct (passive normally closed point at 1.2 points). A03 --- Filter Monitor ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top