1. The series and parallel connection application of contactors Many electrical equipment are single-phase loads, so several poles of multi-pole contactors can be used in parallel. Such as resistance furnaces, welding transformers, etc. When using several poles in parallel, a smaller capacity contactor can be used. However, it must be noted that the agreed heating current of the contactor after parallel connection is not completely proportional to the number of poles in parallel. This is due to the fact that the resistance values of the active and static contact circuits are not necessarily completely equal, so that the current flowing through the active contacts is not evenly distributed. Therefore, the current can only be increased to 1.8 times after the parallel connection of two discontinuations, and the current can only be increased to 2-2.4 times after the parallel connection of the three poles.
In addition, the demand points out that since it is impossible to turn on and off the contacts at all poles after parallel connection, it is not possible to make and break the ability to progress.
Sometimes, several poles of the contactor can be used in series, and the arc can be divided into many segments due to the increase of contact breakage, which improves the arc extinguishing ability and accelerates the extinguishing of the arc. Therefore, several poles can be connected in series to improve their operating voltage, but not exceed the additional insulation voltage of the contactor. The agreed heating current and additional working current of the contactor in series will not change.
2. The influence of power supply frequency Regarding the main circuit, the change of frequency affects the skin effect, and the skin effect increases when the frequency is high, and for most products, 50 Hz and 60 Hz have little impact on the temperature rise of the conductive circuit. However, as far as the lead coil is concerned, it should be noted that the magnetic flux of the magnet wire used in the 50 Hz planning for the magnet wire at 60 Hz will be reduced, and whether it can be used depends on the margin of the plan. In general, it is best for the user to use according to its calibration value, and order according to the operating power frequency used.
3. The influence of the operating frequency The number of operating cycles per hour of the contactor has a great impact on the burning loss of the contact, and attention should be paid to the selection, and the applicable operating frequency is given in the technical parameters of the contactor. When the actual operating frequency of the electrical equipment is higher than the given value, the contactor must be degraded.
|
More on that
|
Interference phenomenon of LS power inverter
1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;
2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter;
3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;
4. Pressure transformer (4-20 ...
|
|
Introduction of LS PLC programming software
LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, which can carry out PLC programming operations such as online modification, debugging and self-diagnosis, packing and debugging, etc., compatible with LG Master-K series and LG MASTER-K series, which can make you in the process of processing in a timely manner.
|
|
Introduction to electrical equipment - LS Electricity
According to the requirements of safe, high-quality, reliable and economical operation of the production, transforming, transportation, distribution and use of electric energy in power plants and substations, the following electrical equipment is mainly included.
1. Primary equipment
Directly involved in production, ...
|
|
Specifications for the use of power converters
Operating regulations for power inverters
Maintenance & Installation
Work according to the weight of the product.
The number of inverter boxes cannot be stacked in excess of the specified number.
Install according to the user manual.
Do not open the case during transport.
Do not place ...
|
|
The application of the inverter to supply power to the motor has encountered a problem
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
...
|
|
Inverter overvoltage alarm analysis - LS power generation
Change the shutdown mode to inertia parking and you're done! In this way, after the fan is stopped, the inverter will immediately turn off the output, so that the fan can stop freely, at this time, although the fan is in the power generation situation, but the electricity generated by the fan will not pass through the inverter of the inverter to generate direct current, so the inverter will not overvoltage ...
|
|
An internal component of LS's power circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
Inverter fault handling - LS power generation
1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working normally;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
...
|
|
Misunderstanding of power-saving and energy-saving use of inverter - LS power generation
Industrial control automation products inverters are described as power-saving, energy-saving control automation products, therefore, many people will think that as long as the equipment is installed with inverters, it will be able to save energy and electricity, but this is not the case.
The inverter of industrial automation products itself produces energy-saving and power-saving ...
|
|
The inverter reads the rated data method - LS power generation
The technical parameters of the inverter (Variable-frequency Drive, VFD) are divided into the input side and the output side. The technical parameters of the input side of the VFD include input voltage, number of phases and frequency; Output-side technical parameters include additional output voltage, additional current, additional capacity, capacity, frequency accuracy, etc.
|
|
The basic problem of LS electric molded case circuit breaker
Rated current of LS molded case circuit breaker:
Now in the process of using the molded case circuit breaker, it is necessary to understand the rated current of the molded case circuit breaker, and the rated current of the molded case circuit breaker is generally more than a dozen, mainly 16A...
|
|
Introduction of LS electric power contactors
How LS Contactor Works:
Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...
|
|
LS power converter interference phenomenon
1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly;
2. Use the inverter to control the water supply, the pressure transformer is used as the signal to collect the pressure, and the pressure transformer is disturbed by the inverter;
3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently;
4. Pressure transformer (4-20 ...
|
|
The protection measures of the power generator inverter for the motor
The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection.
...
|
|
How to select the inverter motor - LS produces electricity
Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is designed at 50Hz, the frequency of 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque operation, frequency 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power operation, the entire speed regulation scale of (0 ...
|
|
The basic method and steps of inverter debugging - power inverter
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset.
|
|
Power production PLC installation and wiring skills
The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifier equipment and large-scale power equipment, and cannot be installed in the same switch cabinet as high-voltage electrical appliances.
Power line, control line and PLC power line and I/O line should be separated from the wiring, barrier transformer and PLC and I/O should be selected ...
|
|
Wiring method of the main circuit of the inverter - LS power generation
1. The power supply should be connected to the R, S, and T terminals of the VFD, and should not be connected to the VFD (U, V, W), otherwise the VFD will be damaged. It is necessary to clean up the trivial parts of the wire head after wiring, which may lead to abnormalities, failures, and failures, and it is necessary for the VFD to always be clean. When punching holes in the console, note that ...
|
|
After the contactor is energized, the start button continuously engages and disconnects ?—— LS generates power
What is the reason why the contactor keeps engaging and disconnecting by pressing the start button after the AC contactor is energized?
In my personal opinion, most of the situation is caused by the wrong coil voltage of the replacement AC contactor, or the purchase of ...
|
|
Inverter circuit structure - LS generates electricity
The main circuit is the power replacement part of the power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is to change the DC of the voltage source to the communication of the DC port of the inverter, and the filter is the capacitor. The current type is to change the DC of the current source to the communication ...
|
|