Specifications for the use of power converters

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Operating regulations for power inverters
Specifications for the use of power converters
  Maintenance & Installation

Work according to the weight of the product.

The number of inverter boxes cannot be stacked in excess of the specified number.

Install according to the user manual.

Do not open the case during transport.

Do not place heavy objects on the inverter.

Check that the inverter is packing in the correct direction.

Do not allow the inverter to be dropped or pinched

connection

Do not mount power factor correction capacitors, surge suppressors, or RFI filters on the output side of the drive.

The order in which the motor output cables (U, V, W) are connected will affect the direction of rotation of the motor.

Incorrect wiring can lead to damage to the device.

The positive and negative connections of the terminal may damage the drive.

They should be wired and inspected by a professional who is familiar with LS drives.

Install the inverter before wiring, otherwise it may cause electric shock or personal injury.

Test run

Check all the parameters before running. The parameters can be modified according to the load.

Ensure that the voltage of each terminal block is within the voltage range specified in the manual, otherwise it will cause damage to the inverter.

Runtime considerations

When the auto-restart function is selected, the device cannot be approached and the motor will suddenly restart after a malfunction.

The Stop button on the control panel is only valid when the corresponding function is set, and the emergency stop switch should be installed separately.

When an external terminal is used as a fault reset signal, it can cause unexpected start-up. Check in advance that the outer terminals are closed, otherwise an accident may occur.

Do not modify or alter the internal parts of the frequencyr.

The electronic thermal protection of the drive may not protect the motor.

The input side of the inverter cannot use the electromagnetic AC contactor as a switch for the inverter to start and stop frequently.

Grounding in accordance with local electrical standards. It is recommended that the 200-volt ground resistance is less than 100 ohms and the 400-volt ground resistance is less than 10 ohms.

The above is part of the use specifications of the power inverter

More on that
The cause of motor burnout caused by the inverter - electricity production The cause of motor burnout caused by the inverter - electricity production

In fact, the fault of the motor is not the cause of the motor itself, most of them are caused by the non-standard debugging of the inverter or the wrong inverter motor when the inverter motor is used, etc., mainly in the following situations: 1. Treat the general motor as a ...

Asynchronous motor with inverter - LS generates electricity Asynchronous motor with inverter - LS generates electricity

Before the asynchronous motor is equipped with an inverter, let's take a look at the three major types of mechanical equipment loads: 1. Constant torque load: such as conveyor belts and mixers; When the inverter drags a load of constant torque nature, the torque at low speed should be large enough and the overload capacity should be large enough. If you need ...

Six misunderstandings in the installation and use of inverters - electricity production Six misunderstandings in the installation and use of inverters - electricity production

Myth 1: Connect electromagnetic switches and electromagnetic touches in the output circuit of the inverter In practical application, some occasions need to use the touch device for frequency converter switching: such as switching to the power frequency state when the frequency conversion is faulty, or the election is used to drag two methods, a motor is faulty, and the variable frequency is used.

Parameter setting of LS power inverter Parameter setting of LS power inverter

The inverter is a high-tech intelligent product, in order to let it complete the specified control mission, it must be set parameters, otherwise, it is like the computer is not installed and used, and it cannot be operated normally. The parameter setting is carried out by the control surface of the inverter. All kinds of inverters ...

Inverter circuit structure - LS generates electricity Inverter circuit structure - LS generates electricity

The main circuit is the power replacement part of the power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is to change the DC of the voltage source to the communication of the DC port of the inverter, and the filter is the capacitor. The current type is to change the DC of the current source to the communication ...

The matrix alternating control mode of the inverter - LS power generation The matrix alternating control mode of the inverter - LS power generation

VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. One of the disadvantages is that the input power factor is low, the harmonic current is large, the DC circuit needs a large energy storage capacitor, and the regenerative energy cannot be reflected back to the grid, that is, it cannot carry out four-quadrant operation.

Introduction to wiring problems - LS power generation Introduction to wiring problems - LS power generation

1. Wiring of fire emergency lighting Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm.

A common fatal form of failure of the terminal block - LS power generation A common fatal form of failure of the terminal block - LS power generation

1. Poor touch The metal conductor inside the terminal block is the core part of the terminal, which transmits the voltage, current or signal from the external wire or cable to the touch piece corresponding to the connector it matches. Therefore, it is necessary for the touch parts to have excellent structure, stable and reliable touch firmness.

The role of contactors in industrial electricity - LS generates electricity The role of contactors in industrial electricity - LS generates electricity

The contactor is an automatic switch in industrial electricity that uses a button to control its on/off. The contactor consists of an electromagnetic coil, a static armature, a moving armature, a static contact, a moving contact and a fixing bracket. The principle is that when the electromagnetic coil of the contactor is connected to the communication electricity, a strong magnetic field will be generated to make the center of the coil ...

LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years. LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.

In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.

Precautions for the use of inverter - LS produces electricity Precautions for the use of inverter - LS produces electricity

1. The inverter should not be installed on the equipment with vibration, because the main circuit connection screw in the inverter is simply loose, and many inverters are damaged due to this reason. Second, the wiring problem: the inverter input termination on an air initial maintenance current value can not be too large, ...

How LS produces power PLC operation How LS produces power PLC operation

Although many relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming methods to make logic control modifications, and connects external machines through output components.

Characteristics of single-phase current converter - LS power generation Characteristics of single-phase current converter - LS power generation

Single-phase current transmitter is a kind of power test substation developed for the power measurement of single-phase AC in motor test on the basis of motor test and test technology research, in accordance with IEC and relevant national specifications for motor test. The selection of advanced filtering technology, reasonable software algorithms, processing ...

Calculation method of filter capacitance value of inverter Calculation method of filter capacitance value of inverter

Alternating current can be converted into direct current using rectifier electricity, but in three-phase electricity, this DC voltage or current contains voltage or current ripple with a frequency of six times the frequency of the power supply. In addition, the inverter inverter will also generate ripple voltage or current due to output and carrier frequency, etc., and reverse ...

The cause of the failure of low-voltage electrical appliances - LS power generation The cause of the failure of low-voltage electrical appliances - LS power generation

In the control circuit of low-voltage electrical appliances, there are simple low-voltage components such as: buttons, safe, etc.; There are also slightly messy low-voltage electrical control components, such as circuit breakers, touch devices, time relays, thermal relays and other simple components, which makes it necessary to diagnose and analyze the cause of the problem. ...

The difference between overload and overcurrent of the inverter The difference between overload and overcurrent of the inverter

(1) The maintenance objectives are different Overcurrent is mainly used to maintain the inverter, whereas overload is mainly used to maintain the motor. Because the capacity of the inverter sometimes needs to be increased by one or even two gears than the capacity of the motor, in this case, the inverter is not necessarily overcurrent when the motor is overloaded. ...

Precautions for the selection of peripheral equipment for LS power inverter Precautions for the selection of peripheral equipment for LS power inverter

The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.

Analysis of the problem of excessive current of LS three-phase motor for power generation Analysis of the problem of excessive current of LS three-phase motor for power generation

First, the power supply problem 1. The power supply voltage is too high When the power supply voltage is too high, the motor back electromotive force, magnetic flux and magnetic flux density all increase. Since the magnitude of the iron loss is proportional to the square of the magnetic flux density, the iron loss increases, resulting in overheating of the core. And the increase in magnetic flux causes ...

Inverter fault handling - LS power generation Inverter fault handling - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working normally; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

The given way of the inverter - LS generates electricity The given way of the inverter - LS generates electricity

Frequency given meaning and given method The speed of the motor can be changed by changing the output frequency of the inverter. In order to adjust the output frequency of the inverter, the inverter must supply the signal of the changed frequency, which is called the frequency given signal.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top