Misunderstanding of power-saving and energy-saving use of inverter - LS power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Industrial control automation products inverters are described as power-saving, energy-saving control automation products, therefore, many people will think that as long as the equipment is installed with inverters, it will be able to save energy and electricity, but this is not the case.

The inverter of industrial automation products itself produces the understanding that energy saving and power saving is a fault. Whether the inverter of industrial automation products can achieve the role of power saving and energy saving also needs to be determined according to the actual situation of use.

                            Misunderstanding of power-saving and energy-saving use of inverter - LS power generation

Myth 1, many people think that the torque of the two motors does not reach the additional torque of the motor in the state of operation (frequency, speed is still the same 50HZ), industrial automation products inverter will also play a role in energy saving, this is a fault of the thought.

Myth 2, two identical motors are operating in the 50HZ power frequency state, one uses the inverter, the other does not, together the speed and torque are in the additional state of the motor, I believe that most people will think that the motor using the inverter will be more energy-saving and power-saving. In fact, this is also a wrong idea.

Myth 3: Under the same conditions, many people think that they can save a lot of electricity in the no-load state, but in fact, the no-load state of the dragged load can not save much electricity.

The reason why the inverter of industrial automation products can achieve the role of power saving and energy saving in most cases is that the inverter controls the speed of the motor, but in fact, most of the speed regulating equipment can reach this role, because it is obvious that we can not determine that the inverter is an energy-saving product.

More on that
LS power production contactor selection LS power production contactor selection

How LS Contactor Works: Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...

The given way of the inverter - LS generates electricity The given way of the inverter - LS generates electricity

Frequency given meaning and given method The speed of the motor can be changed by changing the output frequency of the inverter. In order to adjust the output frequency of the inverter, the inverter must supply the signal of the changed frequency, which is called the frequency given signal.

LS GTH, GTK series thermal relay models LS GTH, GTK series thermal relay models

Thermal Overload Relay GTH-22 GTH series: GTH-22, GTH-40, GTH-85, GTH-100, GTH-150, GTH-220, GTH-400、GTH-600、GTH-12M、GTH-12MH、GTH-12M、GTH-MH GTH series: GTH-22, GTH-40, GTH-85 ...

Electricity-producing permanent magnet AC contactor structure Electricity-producing permanent magnet AC contactor structure

The contactor is mainly composed of a drive system, a contact system, an arc extinguishing system and other parts. 1. Drive system: The drive system includes electronic modules, soft iron, and permanent magnets, which is an important part of the permanent magnet contactor.

Methods for extending the service life of inverters - LS generates electricity Methods for extending the service life of inverters - LS generates electricity

1. The influence of electromagnetic disturbance on the inverter: In the modern industrial control system, the microcomputer or PLC control technology is mostly selected, and in the process of system planning or transformation, it is necessary to pay attention to the disturbance of the inverter to the microcomputer control board. The inverter is disturbed by the outside world, because the user ...

Why can't the inverter be equipped with a leakage protector? Why can't the inverter be equipped with a leakage protector?

When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters. Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...

LS power production contactors are used in this area LS power production contactors are used in this area

LS contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC), which are used in electricity, power distribution and consumption. Contactor in a broad sense refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field and close the contact to control the load in industrial electricity. ...

Analysis of heat dissipation problems of inverter - LS power generation Analysis of heat dissipation problems of inverter - LS power generation

In order to use the inverter correctly, it is necessary to consider that the service life of the VFD decreases exponentially with the increase in temperature. This is due to: When the ambient temperature rises by 10 degrees, the service life of the VFD is halved. So pay attention to heat dissipation! When the VFD is working, the current flowing through the VFD is very large, and the VFD emits ...

The basic problem of LS electric molded case circuit breaker The basic problem of LS electric molded case circuit breaker

Rated current of LS molded case circuit breaker: Now in the process of using the molded case circuit breaker, it is necessary to understand the rated current of the molded case circuit breaker, and the rated current of the molded case circuit breaker is generally more than a dozen, mainly 16A...

Introduction of LS electric power contactors Introduction of LS electric power contactors

How LS Contactor Works: Generally, after the contactor coil is energized, the entire coil current will generate a magnetic field, which will make the core inside have electromagnetic attraction to attract the core, and let their communication contactor point action normally closed contact disconnect, or close, which ...

Inverter control motor operation method - LS power generation Inverter control motor operation method - LS power generation

When the main circuit of the inverter is connected to the power line, in order to control the operation of the motor, it is also necessary to connect the relevant terminals to the peripheral control circuit, and set the parameters of the inverter's starting method to the external operation form. The inverter controls the motor to run, and there are two common methods, which are to turn on the ...

Manufacturing Automation Terminology – LS Electricity Generation Manufacturing Automation Terminology – LS Electricity Generation

I/O Points: When discussing control systems, I/O points are a term that is often heard. It refers to the input/output point, I stands for INPUT, which refers to the input, and O stands for OUTPUT, which refers to the output. The inputs/outputs are for the control system, and the input refers to the ...

The difference between inverter and servo - LS produces electricity The difference between inverter and servo - LS produces electricity

An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation. 1. What the two have in common: The skill of communication servo itself is the learning and application of ...

Common faults and countermeasures of power inverters Common faults and countermeasures of power inverters

1. OC failure Like other inverters, overcurrent alarm is also a common fault of power inverter, in addition to the reasons for parameter settings such as acceleration and deceleration time, there are mainly the following possibilities in hardware: damage to high-power modules may cause OC alarm, low-power economical inverter ...

The essence and use of LS power PLC module The essence and use of LS power PLC module

1. What is PLC? PLC control system, Programmable Logic Controller, programmable logic controller, a digital operation of electronic devices specially designed for industrial production planning, it uses a class of programmable memory, used in its internal storage program, the execution of logic...

The application of the inverter to supply power to the motor has encountered a problem The application of the inverter to supply power to the motor has encountered a problem

A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply. ...

Parameter setting of LS power inverter Parameter setting of LS power inverter

Control method: i.e. speed control, rotation control, PID control or other methods. After adopting the control method, it is generally necessary to carry out static or dynamic identification according to the control accuracy and requirements. Low operating frequency: that is, the small speed of the motor running, when the motor is running at low speed, its heat dissipation function ...

Several basic functions of the inverter - LS generates electricity Several basic functions of the inverter - LS generates electricity

The inverter mainly has the following functions: 1. Soft up The direct launch of the inverter motor will have a severe impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits.

Precautions for the coordination of inverter and PLC - LS produces electricity Precautions for the coordination of inverter and PLC - LS produces electricity

As an alternative to traditional relays, PLC is widely used in various fields of industrial control. Because the PLC can be used to change the control process with software, and has the characteristics of small size, sensitive assembly, simple programming, strong anti-disturbance ability and high reliability, it is especially suitable for operation in harsh environments. ...

Introduction to the control method of LS power inverter Introduction to the control method of LS power inverter

Inverter control method: low-voltage general frequency conversion output voltage is 380-650V, output power is 0.75-400kW, operating frequency is 0-400Hz, and its main circuit adopts AC-DC-AC circuit. Its control methods have gone through the following five generations. 1U/f=C sine pulse width modulation ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top