LS PLC programming software is a professional PLC programming assistant tool, providing excellent interface, can be online modification, debugging and self-diagnosis, cleaning and debugging and other PLC programming operations, compatible with LG Master-K series and LG MASTER-K series, can allow you to control the equipment in time during the processing process.
Functional features
1. User Friendly Interface: Provides a simple and friendly interface for creating, modifying, and monitoring.
2. Online modification: real-time modification can be obtained under the online method. Programs that can be modified online can be downloaded automatically without having to stop the PLC hardware.
3. Monitoring information from PLC: Users can easily monitor the status of PLC, such as: error status, network information and system information.
4. Debugging and self-diagnosis (LG MASTER-K series): Sampling tracking, triggering and forced I/O enable can be obtained in precise debugging.
Software features:
The protocol of the PLC serial port, the setting of the computer serial port must be consistent with the PLC serial port
The ls plc programming software provided the development of KGL equipment and enabled the setting up of the control system
It can be programmed to create a graphic for the control of the device
It is possible to convert the operation plan of industrial communication equipment into code
It can help you quickly design PLC control programs
It provides the function of program creation, and it is possible to choose one of the KGL machines to set up a plc
It provides a link test function, which can establish multiple links and use I/O access devices
There are many PLCs that can be created, and PLC programming design that supports a variety of KGL equipment
Changelog
Improved the ease of modifying graphics
Ability to operate the PLC system on a graphical page
Ability to set the priority of various abort events in the PLC
If you change the type of engineering PLC, it may cause the compilation to be incomplete
Insert the directive or the component corresponding to the directive directly
You can change the name of the program after it has been imported into the project
|
More on that
|
Fault analysis of the main circuit of the inverter - LS power generation
According to the statistical analysis of the frequency and shutdown time of the inverter's detailed common problems, the correction rate of the main power supply circuit accounts for more than 60%; The main operating parameters are not set properly, resulting in about 20% of common problems; Common problems with control circuit boards account for 15%; 5% of common problems are caused by incorrect operation and external anomalies ...
|
|
The inverter reads the rated data method - LS power generation
The technical parameters of the inverter (Variable-frequency Drive, VFD) are divided into the input side and the output side. The technical parameters of the input side of the VFD include input voltage, number of phases and frequency; Output-side technical parameters include additional output voltage, additional current, additional capacity, capacity, frequency accuracy, etc.
|
|
The working principle of LS PLC module
When LS PLC is put into operation, its operation process is generally divided into three stages: input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the ...
|
|
Inverter external potentiometer connection method - LS power generation
The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
The matrix alternating control mode of the inverter - LS power generation
VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. One of the disadvantages is that the input power factor is low, the harmonic current is large, the DC circuit needs a large energy storage capacitor, and the regenerative energy cannot be reflected back to the grid, that is, it cannot carry out four-quadrant operation.
|
|
Introduction to electrical equipment - LS Electricity
According to the requirements of safe, high-quality, reliable and economical operation of the production, transforming, transportation, distribution and use of electric energy in power plants and substations, the following electrical equipment is mainly included.
1. Primary equipment
Directly involved in production, ...
|
|
Precautions for the selection of peripheral equipment for LS power inverter
The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.
|
|
The principle and function of the power production contactor
The working principle of the power production contact is: when the contact coil is energized, the coil current generates a magnetic field, and the generated magnetic field leads the static iron core to produce electromagnetic attraction to the iron core, and drives the AC contact action, the normally closed contact is disconnected, the normally open contact is closed, and the two are connected to each other. When the coil is de-energized, the electric ...
|
|
Energy-saving method of ventilator inverter - LS power generation
high-power
Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...
|
|
The difference between inverter and servo - LS produces electricity
An important difference between servo and frequency conversion is that frequency conversion can be without encoder, while servo must have an encoder for electronic commutation.
1. What the two have in common:
The skill of communication servo itself is the learning and application of ...
|
|
Communication control of inverter - power inverter
The communication control of the inverter is more complicated, so it is listed separately.
The communication control of the inverter is a control method for the operation, speed regulation and status indication of the inverter through the communication interface of the inverter.
...
|
|
The five stages of mastery of PLC technology
One. Logical stage
The so-called logical stage is to be able to complete the general logical planning in the relay system, since it is a relay system, so the knowledge of power drag is the foundation of this stage. I personally summarize that the root of learning the relay system lies in the word "grab", the relay system ...
|
|
The difference between voltage type and current type inverter - LS generates electricity
The differences between voltage type and current type inverter are mainly manifested in:
(1) the load of the buffer inverter of reactive power is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Because power electronic switches ...
|
|
The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity
VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. Its common disadvantages are low input power factor, large harmonic current, large demand for energy storage capacitors in DC circuits, and renewable energy can not be reflected back to the grid, that is, it cannot carry out four-quadrant operation.
|
|
Introduction of LS AC motors
1. AC synchronous motor: that is, the rotor is composed of permanent magnet data, so after rolling, with the change of the stator rotation magnetic field of the motor, the rotor also changes the speed of the response frequency, and the rotor speed = stator speed, so it is called "synchronization".
...
|
|
Types and characteristics of PLC digital output modules for power production
The main functions and functions of PLC:
1. For sequential control: sequential control is based on the current and pre-historical situation of the input switch, and produces the required switching output, so that the system can operate in a certain order. ...
|
|
The reason why the inverter cannot be equipped with a leakage protector
When using an inverter, a leakage maintainer must not be used. This is a major principle of the use of frequency converters.
Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together, the leakage maintainer acts, and the system foundation cannot be ...
|
|
Inverter exception handling method - LS power generation
1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working properly;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
...
|
|
Recommended models for power production contactors
GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V;
GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V;
GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V;
GMC-18 Contactor GMC-18 Rated voltage 110V/ ...
|
|
An integral part of an electrical solid state relay
Solid state relays consist of three parts: the input circuit, the barrier (coupling), and the output circuit.
Input Circuit:
According to the different categories of input voltage, the input circuit can be divided into DC input circuit, communication input circuit and AC-DC ...
|
|