FX Series PLC: FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in specification mode. In the meantime, the FX series 5U is suitable for any industry, and is used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can produce a more advanced mask N95.
Q series PLC: the program memory capacity can reach 252K steps, and the expansion memory can reach 32M, Q series PLC is generally used in large and medium-sized enterprises, because his system is huge.
L series: L series PLC is Mitsubishi's third generation of high-performance PLC, developed on the basis of Q series PLC.
A Series Mitsubishi PLC:
Mitsubishi PLCA series uses Mitsubishi's special sequential control chip (MSP), and the speed/instruction is comparable to that of large Mitsubishi PLC in the United States; A2ASCPU supports 32 PID circuits. The number of circuits in QnASCPU is unlimited, which can be changed with the size of the memory. The program capacity ranges from 8K steps to 124K steps, and the memory of QnASCPU can be expanded to 2M bytes if a memory card is used. There are a variety of special modules to choose from, including network, positioning control, high-speed counting, temperature control and other modules.
PLC series development:
1. Product planning is carried out in two directions: 14,336 I/O points, 32-bit microprocessor, multi-CPU parallel work, large-capacity memory, and high-speed scanning speed. Small: From the overall structure to the small modular structure, the flexibility of configuration is increased and the cost is reduced.
2. PLC is increasingly widely used in closed-loop process control.
3. Continuously strengthen the communication function.
4. New equipment and modules are constantly introduced In addition to the main selection of CPU to improve the processing speed, advanced PLC also has intelligent I/O modules with processors such as EPROM or RAM, high-speed counting modules, and remote I/O modules.
5. Programming things are rich and diverse, the functions are constantly improving, and the programming language tends to be standardized There are various simple or complex programmers and programming software, using ladder diagrams, utility diagrams, sentence lists and other programming languages, as well as advanced PLC instruction systems
6. Carry out fault-tolerant skills and choose hot standby or parallel work and majority voting methods.
7. Seek standardization of software and hardware.
PLC is widely used in agriculture, fishery, transportation, food industry, manufacturing industry, entertainment industry, medical care, environmental protection, energy and other industries! PLC is a new type of industrial automatic control equipment based on relay control, centered on microprocessor, integrating automatic control skills, computer skills and communication skills. At present, PLC has fundamentally replaced the traditional relay control system, and has become an important and widely used control equipment in the field of industrial automation, and is the first of the three pillars of industrial production automation (programmable manipulator, robot, computer-aided design and production).
|
More on that
|
Mitsubishi servo motor one-button adjustment function
In the MR Configurator2 servo commissioning software, Mitsubishi has developed a "one-button adjustment" function to solve the problem of rigid noise of servo motors, as follows:
1. Set PA08 to 0003 and adjust the gain to ...
|
|
Precautions related to transportation control of lithium batteries - Mitsubishi
This Skills Brief introduces the United Nations requirements for lithium battery shipment controls and United States guidelines for lithium battery shipment controls.
In addition, the content shown in this skill newsletter will be discontinued as of March 2020.
...
|
|
Functional characteristics of Mitsubishi's various series of servo motors
Mitsubishi servo motor system series: MR-J2S series, MR-J3 series, MR-ES series, MR-E series.
Mitsubishi servo motor MR-J2S series
1. The product also has RS-232 and RS-422 serial communication functions, which can be used by a personal computer equipped with servo setting software.
|
|
Mitsubishi inverter pre-use debugging steps
1. No-load energizing test of Mitsubishi inverter.
1. Ground the ground terminal of the Mitsubishi inverter.
2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch.
3 Check whether the factory display window of Mitsubishi inverter is normal, if it is not correct.
|
|
A brief description of Mitsubishi's PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. Whereas...
|
|
Mitsubishi servo motor method
1. Torque control: Torque control sets the output torque of the motor shaft through external imitation input or direct address assignment. For example, 10V is equivalent to 5Nm. When the external analog is set to 5V, the output of the motor shaft is 2.5 Nm. If the motor shaft load is less than 2.5 Nm, when the external load is 2.5 N...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation.
...
|
|
Mitsubishi Electric appeared at the 2021 China Smart Expo
From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...
|
|
Mitsubishi PLC FAQs
1. How to connect a PNP three-wire proximity switch to the input port of FX3U PLC.
Answer: The signal output termination of the PNP three-wire system close to the switch is connected to the input port of the PLC, such as X0, and the 0V end of the PNP type close switch to the 0V terminal on the PLC, and the S/S terminal and the 0V terminal ...
|
|
Mitsubishi PLC FX series position control unit
The FX-20GM is a 2-axis positioning machine that can be operated independently.
1. Pulse output unit
1. Point-controlled pulse output unit F2-30GM
2. Pulse output module FX-1PG (for FX2 and FX2C)
...
|
|
Mitsubishi PLC communication detection steps
When you are ready to communicate through AJ71QE71, perform the ping procedure in MS-DOS mode to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. Support communication with Weilun touch screen through serial port.
...
|
|
How to deal with Mitsubishi PLC failures - Mitsubishi
01. Base system problem
In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base.
2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...
|
|
Classification of Mitsubishi touch screens
At present, Mitsubishi contact screens are generally divided into four categories: resistive contact screens, capacitive contact screens, infrared contact screens and surface acoustic contact screens Mitsubishi servo motors.
1. Resistive contact screen
The screen body of the resistive contact screen ...
|
|
Inverter life extension method - Mitsubishi
First, the frequency converter should not be installed on the equipment with a sensation, because the main circuit connection screw in the frequency converter is simply loose, and many frequency converters are damaged due to this reason.
Second, the wiring problem: the input end of the inverter is connected to an air The initial maintenance current should not be too large, ...
|
|
Mitsubishi PLC control inverter method
1. Mitsubishi PLC's analog signal control inverter
Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...
|
|
Mitsubishi MELSEC iQ-F makes IoT a simple one
The MELSEC iQ-F series of small PLCs completes the high-speed system bus, supports a variety of networks, enriches the built-in functions, and makes it more convenient to use. From stand-alone use to network-based system proposals, we strongly support the needs of customers for "cutting-edge products in the manufacturing industry". Using the MELSEC iQ-F...
|
|
The role of Mitsubishi inverters in energy conservation and emission reduction
1. Descend the starting current of the motor
When the motor is started, due to the influence of inertia and load, there will be a large starting current. This current causes fluctuations in grid voltage and energy additions to the grid. The use of frequency converters can effectively solve this problem. After conditioning inverter ...
|
|
PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi
The PLC control cabinet is the final level of equipment in the power distribution system. It mainly protects, supervises and controls the entire circuit, which is convenient for unified management. The power distribution cabinet is a kind of equipment that can reasonably distribute electrical energy and make the circuit easy to open and close. But because it is a circuit device, the requirements for the level of safety protection ...
|
|
Self-locking function of servo motor - Mitsubishi
Press the abort button SB1, the contactor KM coil is de-energized, and the auxiliary normally open contact of the KM connected in parallel with SB2 is disconnected to ensure that the KM coil continues to lose power after the button SB1 is released, and the main contact of the KM connected in series in the motor circuit is continuously disconnected and the motor stops. Auxiliary to the KM in parallel with SB2 ...
|
|
Analysis of PLC and inverter connection problems - Mitsubishi
When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1. PLC switch command signal input
Inverter input ...
|
|