Mitsubishi takes instructions and outputs instructions

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

1) LD (take instruction) A command to connect a normally open contact with the left bus, and every logic line that starts with a normally open contact is used with this instruction;

                              Mitsubishi takes instructions and outputs instructions

2) LDI (Negative Command) A normally closed contact is connected to the left bus, and every logic line starting with a normally closed contact is used with this instruction;

3) LDP (take the rising edge command) The rising edge detection command of the normally open contact connected with the left busbar is only connected to one scan cycle when the rising edge of the specified bit component (OFF→ON);

4) LDF (take the falling edge command) The falling edge detection command of the normally closed contact connected with the left bus;

5) OUT (Output Instruction) A command to drive a coil, also known as an output instruction.

More on that
Advantages and disadvantages of Mitsubishi's different output types Advantages and disadvantages of Mitsubishi's different output types

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The biggest advantage is that it is adapted to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...

Inverter overload fault factor - Mitsubishi inverter Inverter overload fault factor - Mitsubishi inverter

1) The mechanical load is too heavy The main characteristic of overload is the fever of the motor, and it can be detected by reading the operating current from the display. The main factor is that the load of Mitsubishi inverter is too large, and the acceleration and deceleration time and operation cycle time are too tight; V/F features voltage too ...

The difference between a motion controller and a PLC – Mitsubishi The difference between a motion controller and a PLC – Mitsubishi

1. Motion manipulator The use of motion control in the field of robotics and CNC machines is more chaotic than in specialized machines, which are more sketchy and often referred to as General Motion Control (GMC). 2.plc Programmable logic manipulators are a kind of specialized ...

The essential difference between single-chip microcomputer and PLC - Mitsubishi PLC The essential difference between single-chip microcomputer and PLC - Mitsubishi PLC

The difference between PLC and single-chip microcomputer: 1. PLC is a relatively sophisticated control system composed of single-chip microcomputer, and it is a product of the sophisticated and stable single-chip microcomputer application system that has been debugged. There is strong versatility. 2. The single-chip microcomputer can constitute a variety of application systems, and the scale of application ...

Mitsubishi inverter capacity selection points Mitsubishi inverter capacity selection points

The capacity (non-functional) of the Mitsubishi inverter of the drive motor can be understood from the change in energy activity determined by the operating method. 1. When operating at speed or constant speed The efficiency of the inverter is the output current, which is the ...

Mitsubishi inverter setting parameter adjustment method Mitsubishi inverter setting parameter adjustment method

Mitsubishi inverter has many setting parameters, each parameter has a certain selection scale, and the inverter can not work normally due to improper setting of a single parameter in the application. Let's take a look at the Mitsubishi inverter parameter setting operation. ...

Mitsubishi PLC Comparison Instruction Application Mitsubishi PLC Comparison Instruction Application

1. Compare the instruction CMP 1)。 16-bit arithmetic (CMP, CMPP) compares the contents of the comparison value S1 with the comparison source S2, and according to the results (small, - zhi, large), D, D+1, D+2 - one is ON. ...

Software or hardware reasons for Mitsubishi PLC crash Software or hardware reasons for Mitsubishi PLC crash

1. Hardware (1) I/O channeling, the PLC automatically detects the I/O fault and enters the STOP mode. (2) The I/O is damaged, and the program runs to the response signal that needs the I/O, and cannot execute the instruction downward. (3) Expansion module (functional, such as A/D) ...

Mitsubishi PLC encryption process Mitsubishi PLC encryption process

The encryption process is as follows: ** Open the serial port for the first time [00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here) [00000000] IOCTL_SERIAL_SET_LIN ...

Malfunction caused by capacitance between PLC input lines – Mitsubishi Malfunction caused by capacitance between PLC input lines – Mitsubishi

There is a capacitance between the wires of the cable, and a qualified cable can limit this capacitance to a certain size. It is a qualified cable, when the cable length exceeds a certain length, the capacitance value between the lines will also exceed the required value, when the cable is used for PLC input, the capacitance between the lines will be ...

MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT

With the spread of industrial robots in the production site, more and more on-site issues need to be solved, such as the need for more robot programming engineers, which increases the human cost; The teaching is complicated, which increases a lot of non-production time; Set up guardrails to increase the cost of space and installations; Robot...

Mitsubishi FX3u interrupts the location command Mitsubishi FX3u interrupts the location command

The main effect of aborting the positioning instruction is that in some machine tools, when we give the abort signal and can walk to the distance we set, for example, if the mechanical structure needs to use the sensor to determine the position to go, you can use the abort positioning instruction to do, when the induction gives the abort.

Mitsubishi servo motor method Mitsubishi servo motor method

1. Torque control: Torque control sets the output torque of the motor shaft through external imitation input or direct address assignment. For example, 10V is equivalent to 5Nm. When the external analog is set to 5V, the output of the motor shaft is 2.5 Nm. If the motor shaft load is less than 2.5 Nm, when the external load is 2.5 N...

Maintenance method of Mitsubishi inverter Maintenance method of Mitsubishi inverter

Electrical characteristics view Mitsubishi inverters that have been running and placed for a long time, due to the influence of the environment and the aging of inverter equipment, it is necessary to check and maintain the electrical performance of Mitsubishi inverters regularly. A comprehensive review of the input, rectifier and inverter, DC input fuses found ...

Mitsubishi Electric CNC numerical control system grounding specification Mitsubishi Electric CNC numerical control system grounding specification

What is the effect of machine tool grounding? 1. Insist that the machine shell and the ground insist on the same voltage. 2. In the event of abnormal external voltage or leakage, the maintenance personnel and the machine tool will not be damaged electrically. 3. Avoid damage to CNC equipment caused by external voltages such as surges. 4. ...

Which components in the Mitsubishi inverter need to be replaced regularly Which components in the Mitsubishi inverter need to be replaced regularly

Mitsubishi inverter is composed of many electronic parts, such as semiconductor components, etc., in the application and protection involves the replacement of a related component, because of the composition or physical characteristics of the inverter, in a certain period of time will deteriorate, thus reducing the characteristics of the inverter, is ...

There is no self-locking reason for the Mitsubishi servo motor to be turned on There is no self-locking reason for the Mitsubishi servo motor to be turned on

In some cases, when the user first touches the use of the Mitsubishi servo motor, it may appear that the Mitsubishi servo motor is not self-locking after it is ready! So, what is the reason for this? And how to deal with it? ...

Mitsubishi FR-A840 series inverter is coming "strong". Mitsubishi FR-A840 series inverter is coming "strong".

Mitsubishi Electric Automation Corporation has launched the A800 Series Integrated Inverter Drive (VFD) for fast, reliable, easy-to-use, and easy integration and installation for occupational demand drives. The A800 series variable frequency drive combines traditional induction and permanent magnet vehicles into a single solution that supplies ...

Query Error Code Method – Mitsubishi Query Error Code Method – Mitsubishi

Error Number (D8063): 6314 ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL) Error content: Parallel operation string abnormal Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...

Mitsubishi FX series PLC master control command Mitsubishi FX series PLC master control command

The FX2N has a total of 27 fundamental logic instructions, including 20 fundamental logic instructions of some sub-series PLCs. Master Control Command (MC/MCR) (1) MC (Master Control Command) for common tandem contacts ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top