1. How many light sources are there for the TL-70 police light?

There are 3 types, namely LED, incandescent and xenon.

2. What are the colors of the TL-70 police light?

There are 5 types, which are red, yellow, green, blue, and white.

3. What are the types of TL-70 police lights?

There are 3 types, which are Solid, Shiny or Burst and Bright

4. What are the different forms of APT police light buzzer?

2 types, intermittent and continuous.

5. What is the protection level of TL-70?

  IP65

6. What is the volume of the TL-70 buzzer?

>100dB (10cm from the horizontal direction of the sound source)

7. What voltages can be used for TL-70?

  "LED:AC/DC12V,24V,36V,48V,75V,110V,AC220V 氙灯:AC/DC12V,24V,110V,AC220V "

8. How many light sources does the TL-703 police light have?

1 type, LED

9. What are the colors of the TL-703 police light?

There are 5 types, which are red, yellow, green, blue, and white.

10. What are the types of TL-703 police lights?

There are 3 types, which are solid, shiny and bright.

11. What are the different forms of APT police light buzzer?

3 types, intermittent, continuous and musical type buzzers.

12. What is the degree of protection of TL-703? IP65

  IP65

13. What is the volume of the TL-703 buzzer?

>90dB (10cm from the horizontal direction of the sound source)

14. What voltages can TL-703 do?

  "LED:AC/DC12V,24V,36V,48V,75V,110V,AC220V 氙灯:AC/DC12V,24V,110V,AC220V "

15. Can I order the TL-701 as a whole?

No, you can only order parts and then assemble them.

16. Single-lamp type police lights

  TL-701

17. Can the TL-90 be mounted with three holes?

Yes, but the 3-hole installation will destroy the protection level of the police light.

18. What is the protection level of TL-90?

IP65 (single light or siren sound and light integration), IP40 (buzzer sound)

19. What is the maximum number of layers for the TL-50 and TL-501?

TL-50 and TL-501 can be long, and you can do 5 layers of light-emitting layers.

20. What is the range of TL-50 and TL-501 aluminum rods?

TL-50 and TL-501 aluminum rods can theoretically achieve Z0 at the shortest, and the highest is about Z1000.
Siemens apt - TL series police lights frequently asked questions


More on that
Siemens APT – PB1 Series FAQs Siemens APT – PB1 Series FAQs

1. What are the installation methods of PB1 button? PB1S and PB1L are fastened with metal screws, and PB1J and PL1 are fastened with plastic nuts. 2. PB1 series pushbuttons can be assembled with up to several sets of contact modules as standard 2*3=6 3. PB1S shell ...

Siemens APT LA39 series button FAQ Siemens APT LA39 series button FAQ

1. What are the installation methods of LA39-A/B/C button? There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device 2. LA39 series products can be used ...

Siemens APT current transformers – factors influencing the error of current transformers Siemens APT current transformers – factors influencing the error of current transformers

(1) The influence of the internal resistance R2 and leakage impedance X2 of the secondary coil on the error: when R2 increases, the specific difference and angular difference increase; As X2 increases, the specific difference increases, but the angular difference decreases. Therefore, to improve the error, R2 and the appropriate X2 value should be minimized. Due to the secondary coil internal resistance R2 and leakage ...

Siemens APT - LW39 series 10,000 revolutions FAQ Siemens APT - LW39 series 10,000 revolutions FAQ

1. What are the current specifications of universal transfer switches? At present, there are four forms: 10A, 16A, 25A, and 63A 2. What are the positioning angles of the universal transfer switch? At present, it is divided into four angles: 30°, 45°, 60° and 90° 3. There is no customer's ...

Siemens APT Relays - Common Problems and Solutions of Relays Siemens APT Relays - Common Problems and Solutions of Relays

First, the contact is loose and cracks The contact is the electrical contact part of the relay to complete the switching load, and the contact of some products is riveted and pressed, and its main drawbacks are loose contacts, cracked contacts or excessive dimensional position deviation. This will affect the contact reliability of the relay. Shovel appears ...

Siemens APT Relays – The difference between solid state relays and intermediate relays Siemens APT Relays – The difference between solid state relays and intermediate relays

First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life; Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in; ...

Siemens APT Relays - What are the common faults of relays? Siemens APT Relays - What are the common faults of relays?

1. Contact failure (1) The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion and pit formed on the contact bite each other), fusion welding, or cold welding. (2) The contact wear of the relay is caused by the absence of arc extinguishing devices or measures, or improper parameter selection, ...

ALH-0.66 series transformer FAQ ALH-0.66 series transformer FAQ

1. What is the maximum voltage that can be used for an ALH transformer? AC low voltage up to 720V 2. Is there a protective grade product for ALH transformers? II-P AND III-P are available in both protective grades 3. What is the maximum primary current of ALH transformer? The maximum primary side current is 8 ...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

Siemens APT Relays – Selection Principles for High Voltage Relays Siemens APT Relays – Selection Principles for High Voltage Relays

1. Electrical parameter matching: The rated voltage and current of the high-voltage relay need to match the circuit demand, too small will lead to the failure of the switch, too large will waste the cost. 2. Mechanical parameter adaptation: the external dimensions, pin arrangement and wiring mode of the high-voltage relay need to be adapted to the actual installation ring.

APT made a wonderful appearance at the Northeast Automation Exhibition APT made a wonderful appearance at the Northeast Automation Exhibition

On March 31, 2009, the 12th Northeast International Instrumentation and Industrial Automation Exhibition was successfully opened in Shenyang, the industrial hinterland of Northeast China. In recent years, with the national revitalization of the old industrial base in Northeast China and the gradual deepening of the equipment manufacturing industry, the rapid development of Northeast China has provided ...

Siemens APT - x.R series relays frequently asked questions Siemens APT - x.R series relays frequently asked questions

1. Does the AC control relay have surge suppression? SR/NR/PR can produce AC with surge suppression circuits 2. How many types of thermal current specifications are there for our company's relays? 3A, 5A, 8A, 10A, 12A five current specifications 3. Surge suppression back ...

Siemens APT – X-Series Control Box FAQ Siemens APT – X-Series Control Box FAQ

1. The control box is made of ABS and PC, which material has better flame retardant performance? ABS has good flame retardant performance. 2. What are the certifications for the control box? 3C & CE (for unperforated control box only) 3. What is the color of the grey cabinet of the control box? Work...

Siemens APT Relays – The difference between AC relays and DC relays Siemens APT Relays – The difference between AC relays and DC relays

1. Structural characteristics of AC relays The coil of the AC relay is shorter, and the wire diameter is thicker, mainly because the coil is passed through the alternating current, the reactance is larger, and the thick wire diameter can reduce the internal resistance and reduce the heat generation.

AD16-30JC Series Combination Light FAQ AD16-30JC Series Combination Light FAQ

1. What are the basic combination colors of combination lights? Red, yellow, green, blue, white, bicolor. 2. What are the different types of combination light panes? F, H, L, V, G any combination 3. Is the lampshade detachable? OK 4. Combination light ...

Siemens APT warning light - the role of LED warning light in life Siemens APT warning light - the role of LED warning light in life

LED warning light function 1. The luminous method selection items are: solid light, shiny, burst flash, constant/shiny mix. 2. The installation base is: L rod, straight rod, folding, and barrel type. Effect of LED warning light_Effect in different scenes 1. Construction unit On the road ...

Siemens APT current transformer - inspection content of current transformer Siemens APT current transformer - inspection content of current transformer

1. Regularly check whether the current transformer is overheated, check whether there is discoloration in the terminal, and check whether there are sundries in the terminal box. 2. Check whether there is oil leakage in the oil level gauge in time to ensure that the oil level meets the use standard and there is no oil leakage.

Siemens APT current transformer – precautions for current transformers Siemens APT current transformer – precautions for current transformers

1. Before the installation of the open current transformer, it must be connected to the meter (or other measuring devices) for the second time to ensure that the transformer is not open for the second time; 2. Place all the open current transformers connected to the secondary line on the site and wait for installation; 3. If the on-site bus is electrical...

Siemens APT Relays - the main product technical parameters of relays Siemens APT Relays - the main product technical parameters of relays

(1) Rated working voltage: refers to the voltage required by the coil when the relay is working normally. Depending on the type of relay, it can be either AC voltage or DC voltage. (2) DC resistance: refers to the DC resistance of the coil in the relay, which can be measured by a multimeter. ...

Siemens APT PB3 series of quick-fit pushbuttons wins CAIMRS "Automation Innovation Award" Siemens APT PB3 series of quick-fit pushbuttons wins CAIMRS "Automation Innovation Award"

On August 26, the CAIMRS2022 China Automation + Digital Industry Annual Conference was held in Beijing. Based on the fields of automation, digitalization, industrial robotics and industrial interconnection, this conference shared top digital innovation ideas, discussed the latest trends in the industry, and how to grasp the new round of science and technology.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top