1. The control box is made of ABS and PC, which material has better flame retardant performance?
ABS has good flame retardant performance.
2. What are the certifications for the control box?
3C & CE (for unperforated control box only)
3. What is the color of the grey cabinet of the control box?
Industrial Ash, RAL7032
4. What are the two levels of protection of the control box?
The clamshell type control box is IP54 and the rest of the control box is IP65. (for unperforated control boxes only)
5. What are the materials of the control box produced by APT?
ABS and PC. Both ABS and PC are made of plastic, both of which have the characteristics of good toughness and high strength.
6. What is the flame retardant rating of ABS and PC?
ABS:V0;PC:V2
7. What is the operating temperature range of the control box?
-5℃——+40℃
8. What is the storage temperature range of the control box?
-25℃——55 ℃
9. What are the colors of the top cover of the APT control box?
"There are three colors for the lid of the control box, the first is ordinary gray, the second is yellow, and the third is transparent; And a special custom orange color"
10. What are the colors of the APT control box base?
There are two colors of the control box base, the first is gray, the second is black, and the models of the black base are only XK-A series and XK-6 series
11. Why can't the XK-A series install the LA39 button with two or more layers of contacts?
The overall height of the XK-A series button box is only 58.5 mm, and the height of the two layers of contacts of the LA39 is 74 mm, which exceeds the overall height of the button box and cannot be installed.
12. Can the control box be fitted with both the rails and the lower mounting plate?
Since the factory's rails are standard, the factory's control box will not have both a mounting plate and a rail. However, the customer can process the guide rails on top of the mounting plate by themselves.
13. XK-13 series - What is the difference between the gray cover and the transparent cover of the control box of the XK-16 series?
In addition to the different colors, the transparent cover is made of PC material, and the gray cover is normal if the order model does not add -PC, and the material is ABS.
14. Can the control box be customized according to customer needs?
Yes, but there is a problem with minimum quantification.
15. How many seats are there in the transparent window of the XX maintenance box?
11-bit, there is only one kind of transparent window, and the window cannot be added when customizing.
16. Will the socket model mentioned in the scheme number provided by the XX maintenance box be installed and shipped?
No, the plan is just an example, if you need to install, please consult before ordering.
17. Can the XK-7 series and XK-11 series be rated without knockout holes?
No, most of them will react before they have been decided, the truth is that they have never been produced.
18. If the customer chooses the model XK-6/kP-Y and wants the opening scheme number 002, how to order
When ordering, the direct model is XK-6/kP-Y002, and the model can be provided to the customer, and there is no need to apply for drawings. For example, the other models are analogous to the order models of the program number.
19. Can the XKA series control box be equipped with rails?
Since there are no mounting posts on the base of the control box of the XKA series, it is not possible to install the rails
20. Which models can fix the control box without opening the lid?
XK-6 series and XK-12 series.
|
More on that
|
APT won the 2014 Top Ten Cutting-edge Enterprises in China's Automation Field
On April 22, 2015, the "2015 China Automation Industry Annual Conference and the 10th China Automation Industry Century Event" sponsored by the Chinese Association of Automation was held in Beijing. At the conference, APT won the "2014 Top Ten New Enterprises in China's Automation Field" award, which was awarded by APT last year.
|
|
Siemens APT - x.R series relays frequently asked questions
1. Does the AC control relay have surge suppression?
SR/NR/PR can produce AC with surge suppression circuits
2. How many types of thermal current specifications are there for our company's relays?
3A, 5A, 8A, 10A, 12A five current specifications
3. Surge suppression back ...
|
|
Siemens APT Relays – Analysis of Common Faults and Causes of Relays
1. Overhaul of the sensing mechanism
For electromagnetic (voltage, current, intermediate) relays, the sensing mechanism is the electromagnetic system. The faults of the electromagnetic system are mainly concentrated in the coil and the moving and static iron cores.
(1) Coil fault maintenance
Coil failure usually has a coil absolute...
|
|
Siemens APT relay - common faults and solutions for high-voltage relays
1. Poor contact
Poor contact is one of the most common faults in high-voltage relays, which can lead to problems such as hot terminals ® and burned contacts. Workarounds include regularly checking terminals and set screws for loose and cleaning contact surfaces.
2. Excessive wear
At...
|
|
Siemens APT current transformers – precautions for the use of current transformers
1) The wiring of the current transformer should comply with the principle of series connection: that is, the primary winding resistance should be connected in series with the tested circuit, while the secondary winding resistance should be connected in series with all instrument loads
2) According to the size of the measured current, select the appropriate transformation ratio, otherwise the error will increase. At the same time, one end of the secondary side must be grounded in case ...
|
|
Siemens APT Relays – Reliability of Relays
1. The influence of the environment on the reliability of the relay: the average time between failures of the relay is the highest under GB and SF, reaching 820,000h, while in the NU environment, it is only 60,000h.
2. The influence of quality grade on the reliability of relays: when the relay of A1 quality grade is selected, the flat ...
|
|
Siemens APT Relays - Selection Method for Solid State Relays
1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.
|
|
Siemens APT Relays – Components of Solid State Relays
Solid state relays consist of three parts: the input circuit, the isolation (coupling), and the output circuit.
Input circuitry
According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, AC input circuit and AC and DC input circuit. Some input control circuits are also ...
|
|
Siemens APT - ALS series limit switch FAQ
1. What are the installation methods of ALS limit switches?
Usually the limit switch is divided into front of the board installation or board back installation, all of which are installed by screws.
2. What are the different modes of limit switch action?
According to the action mode of the limit switch head, it is divided into ...
|
|
Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?
There are several types of pushbutton switches:
Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...
|
|
Introduction to the characteristics of Siemens APT ZY2 miniature relay
1. Various specifications, with indicator light, with manual test button, with surge suppression loop and other functions
2. Coil control voltage DC6V-220V, AC6V-240V (50/60HZ)
3. The rail type is equipped with a variety of adaptation sockets
4. LED indicator, DC is green, AC is red
...
|
|
Siemens APT Relays – Protection Measures for AC Solid State Relays
1. Selection of voltage level and overvoltage protection of solid-state relay
When the voltage peak value applied to the AC terminal of the solid state relay exceeds the maximum voltage peak that the AC solid state relay can bear, the components in the solid state relay will be broken down by the voltage and cause damage to the AC solid state relay, ...
|
|
Siemens APT helps Tianjin's advanced manufacturing industry
Tianjin is a typical industrial city. Due to the steady progress of "three districts and one base", the advanced manufacturing industry has developed rapidly in recent years. Siemens APT brought a variety of low-voltage control products to the 14th China (Tianjin) International Industry Fair held from March 15-18. Siemens APT has launched the PB1...
|
|
TL series police lights frequently asked questions
1. How many light sources are there for the TL-70 police light?
There are 3 types, namely LED, incandescent and xenon.
2. What are the colors of the TL-70 police light?
There are 5 types, which are red, yellow, green, blue, and white.
3. What are the types of TL-70 police lights?
3 ...
|
|
Siemens APT relays – classified according to the protection characteristics of the relays
(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium.
(2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...
|
|
Siemens APT current transformer - working principle and characteristics of current transformer
How a current transformer works
The principle of current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. It has a small number of turns on the primary side winding, stringed in the line where the current needs to be measured, so it often has the full current of the line ...
|
|
Siemens APT Relays - Maintenance Methods for Solid State Relays
1. The influence of the ambient temperature
The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be dissipated.
|
|
Siemens APT limit switch - wiring method of limit switch
1. First of all, there is a general understanding of the knowledge of the limit switch, which is usually composed of a shell, an interconnection system and an operating head.
2. First of all, the limit switch should be set to the desired location, and then connected, in addition, it is necessary to figure out the meaning of different letters, such as NC for the long ...
|
|
Siemens APT Current Transformer - The difference between voltage transformer and current transformer
The difference between the voltage transformer and the current transformer in terms of effect principle The primary difference is that the operating conditions are very different during normal operation, and the main performance is as follows:
1) The current transformer can be short-circuited twice, but it cannot be opened; The voltage transformer can be opened twice, but it must not be short-circuited
2) ...
|
|
AD16-30JC Series Combination Light FAQ
1. What are the basic combination colors of combination lights?
Red, yellow, green, blue, white, bicolor.
2. What are the different types of combination light panes?
F, H, L, V, G any combination
3. Is the lampshade detachable?
OK
4. Combination light ...
|
|