1. Does the AC control relay have surge suppression?
SR/NR/PR can produce AC with surge suppression circuits
2. How many types of thermal current specifications are there for our company's relays?
3A, 5A, 8A, 10A, 12A five current specifications
3. What is the function of the surge suppression circuit?
Self-generated surges are suppressed to eliminate the impact on external circuits
4. What is the manual button function?
Manually change the contact state, which is convenient for debugging and maintenance
5. What is the form of the relay indicator?
With the coil sucking contract, AC bright red, DC bright green
6. How are the relays installed?
It is usually used in conjunction with the base and is snapped on a 35mm rail
7. What is the pick-up time of SR series relays?
Less than 20ms
8. What type of base is a detachable base?
SYFK
9. What is the mechanical life of the ER series relays?
2x107
10. What are the installation methods of X.R series relays?
Plug-in installation
11. How many times is the mechanical life of NR series relays?
2X107
12. How many contact forms are there for APT's miniature control relays?
There are 2 groups, 3 groups, and 4 groups of three forms
13. What is the ambient temperature of the X.R series relays?
Except for SR series, which are -25°C-+55°C, SR series is -40°C-+70°C
14. What are the installation methods of X.R series relays?
Plug-in installation
15. What does contact capacity mean?
The maximum current that is allowed to pass through the contacts of the relay at the rated voltage
16. Can the positive and negative poles be reversed?
"It is not recommended to use reverse connection, because reverse connection use may not work normally; Only without lights and surge suppression can the positive and negative poles of the coil be connected and reverse."
17. What parameters should I focus on when changing models?
It is necessary to pay attention to the rated working voltage, the agreed heating current, the contact capacity, and the number of contacts
18. Do our control relays have UL certification?
It has UL certification
19. Is there a relay with 1 set of contacts?
Yes, SR series
20. Can DC24V relay be used on AC?
No, it will affect the life of the relay
|
More on that
|
Siemens APT Relays – Maintenance of high-voltage relays
1. Regular cleaning: The relay needs to be cleaned regularly with dust and dirt to keep its surface clean and smooth. It can be cleaned with a clean cloth or brush, and detergents containing acids and bases should be avoided.
2. Check the wiring: The wiring of the relay needs to be fastened firmly, and the contact ...
|
|
Siemens APT current transformer - what need to be paid attention to in the use of current transformer
1. The secondary side of the current transformer shall not be open when working. Due to the small secondary impedance of the current transformer, the secondary side of the current transformer is close to the short-circuit state during normal operation. When the secondary side is open, a high voltage will be induced, which endangers the safety of people and equipment.
2. Electricity ...
|
|
Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays
merit
1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.
|
|
Siemens APT Relays – Common Causes of Failure of Solid State Relays
1. The reason for the frequent disconnection of the coil: whether the solid state relay is cleaned with ultrasonic, whether the coil is overvoltaged, etc., will cause the coil to be disconnected.
2. The reason for the insufficient power supply of the coil: First, it is necessary to confirm the voltage of the solid state relay coil. If the voltage supplied to the coil is lower than ...
|
|
Siemens APT limit switches – the difference between proximity switches and travel switches
01 The role is different
Proximity switches are contactless switches with a long life and are suitable for "pass-through signals". The travel switch is also known as the limit switch, the travel switch and the limit switch are both position switches, but the travel switch can detect the stroke, and can be used as an input signal to control the circuit at a certain distance ...
|
|
Siemens APT current transformer - working principle and characteristics of current transformer
How a current transformer works
The principle of current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. It has a small number of turns on the primary side winding, stringed in the line where the current needs to be measured, so it often has the full current of the line ...
|
|
Siemens APT transformer – common faults and analysis of voltage transformers
(1) The insulation between the iron chips is damaged
Problem: The temperature rises during operation.
Possible causes of the problem:
(1) Poor insulation between iron chips
(2) The use of harsh environmental conditions or long-term operation at high temperature to promote the aging of insulation between iron chips.
( ...
|
|
Siemens apt - TL series police lights frequently asked questions
1. How many light sources are there for the TL-70 police light?
There are 3 types, namely LED, incandescent and xenon.
2. What are the colors of the TL-70 police light?
There are 5 types, which are red, yellow, green, blue, and white.
3. What are the types of TL-70 police lights?
3 ...
|
|
Siemens APT Current Transformers – How to view current transformers
1. Standardize current transformer: the top of the transformer verification is used as a standardizer, and the accuracy is usually more than two grades higher than that of the tested.
2. Load box: imitate the practice operation status of the tested transformer.
3. Transformer ...
|
|
AD16-30JC Series Combination Light FAQ
1. What are the basic combination colors of combination lights?
Red, yellow, green, blue, white, bicolor.
2. What are the different types of combination light panes?
F, H, L, V, G any combination
3. Is the lampshade detachable?
OK
4. Combination light ...
|
|
Siemens APT Relays – Components of Solid State Relays
Solid state relays consist of three parts: the input circuit, the isolation (coupling), and the output circuit.
Input circuitry
According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, AC input circuit and AC and DC input circuit. Some input control circuits are also ...
|
|
Siemens APT LA39 series button FAQ
1. What are the installation methods of LA39-A/B/C button?
There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device
2. LA39 series products can be used ...
|
|
Siemens APT relay - the cause and solution of the fault of the high-voltage relay
1. Some common faults of high-voltage relay coils
1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.
2 ...
|
|
Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches
Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.
|
|
Siemens APT current transformer - precautions for the use of current transformer
1. The wiring of the current transformer should not present problems, otherwise it will lead to failure to operate normally, and there may be damage to the transformer. In this case, the primary winding needs to be connected in series with the measurement circuit, and the secondary winding needs to be connected in series with all the loads.
2. Estimation ...
|
|
APT made a wonderful appearance at the Northeast Automation Exhibition
On March 31, 2009, the 12th Northeast International Instrumentation and Industrial Automation Exhibition was successfully opened in Shenyang, the industrial hinterland of Northeast China. In recent years, with the national revitalization of the old industrial base in Northeast China and the gradual deepening of the equipment manufacturing industry, the rapid development of Northeast China has provided ...
|
|
What are the main problems with Siemens APT Relays – Solid State Relays?
When the solid state relay is open and there is voltage at the load end, there will be a certain leakage current at the output end, and care should be taken to prevent electric shock when using or designing. When the solid-state relay fails to be replaced, the original model or the product with the same technical parameters should be selected as far as possible, so as to match the original application line and ensure that the system ...
|
|
APT won the 2014 Top Ten Cutting-edge Enterprises in China's Automation Field
On April 22, 2015, the "2015 China Automation Industry Annual Conference and the 10th China Automation Industry Century Event" sponsored by the Chinese Association of Automation was held in Beijing. At the conference, APT won the "2014 Top Ten New Enterprises in China's Automation Field" award, which was awarded by APT last year.
|
|
Siemens APT Relays – classified by their operating principle or structural characteristics
(1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature.
(2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated.
|
|
Siemens APT relays – classified according to the protection characteristics of the relays
(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium.
(2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...
|
|