Siemens APT Relays – Selection Principles for High Voltage Relays

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. Electrical parameter matching: The rated voltage and current of the high-voltage relay need to match the circuit demand, too small will lead to the failure of the switch, too large will waste the cost.

2. Mechanical parameter adaptation: The dimensions, pin arrangement and wiring method of the high-voltage relay need to adapt to the actual installation environment to ensure that the switchgear can be installed and operated smoothly.

3. Reliability considerations: The reliability of high-voltage relays is the premise of ensuring the stable operation of the circuit, and certified, high-quality, excellent life, stable and reliable relays should be selected.

4. Environmental factors such as temperature: the selection of high-voltage relays should also consider the environment in which it works, because environmental factors such as temperature and humidity will affect its working performance, and relays suitable for the current environment should be selected to avoid affecting the normal operation of electrical control equipment.

5. Price factor: the price difference of high-voltage relay is large, according to the value and scale of machinery and equipment, combined with the above factors, choose cost-effective, reliable quality high-voltage relay.
Siemens APT Relays – Selection Principles for High Voltage Relays

More on that
Siemens APT Relays – Components of Solid State Relays Siemens APT Relays – Components of Solid State Relays

Solid state relays consist of three parts: the input circuit, the isolation (coupling), and the output circuit. Input circuitry According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, AC input circuit and AC and DC input circuit. Some input control circuits are also ...

Siemens APT Relays - What are the classifications of high and low voltage relays? Siemens APT Relays - What are the classifications of high and low voltage relays?

1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the circuit in the input circuit between the electromagnet core and the armature. 2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated. ...

Siemens APT Current Transformer - The difference between voltage transformer and current transformer Siemens APT Current Transformer - The difference between voltage transformer and current transformer

The difference between the voltage transformer and the current transformer in terms of effect principle The primary difference is that the operating conditions are very different during normal operation, and the main performance is as follows: 1) The current transformer can be short-circuited twice, but it cannot be opened; The voltage transformer can be opened twice, but it must not be short-circuited 2) ...

Siemens APT Relays – How to Choose the Right Power Relay Siemens APT Relays – How to Choose the Right Power Relay

1. Measure the resistance of the contact Use the resistance level of the universal meter to measure the resistance of the normally closed contact and the moving point, and its resistance value should be 0, (the contact resistance value can be measured in a more accurate way within 100 milliohms); The resistance between the normally open contact and the moving point is infinite. From this, it can be distinguished which is a normally closed contact ...

Siemens APT current transformer - common faults and solutions of current transformers Siemens APT current transformer - common faults and solutions of current transformers

1. There is an abnormal noise or over-temperature of the iron core Cause of failure: When the current transformer is in operation, if there is an open circuit or overload in the secondary circuit, it will lead to abnormal sound and over-temperature of the core.

Siemens APT Relays - the main product technical parameters of relays Siemens APT Relays - the main product technical parameters of relays

(1) Rated working voltage: refers to the voltage required by the coil when the relay is working normally. Depending on the type of relay, it can be either AC voltage or DC voltage. (2) DC resistance: refers to the DC resistance of the coil in the relay, which can be measured by a multimeter. ...

Siemens APT Relays – an introduction to the new type of relay Siemens APT Relays – an introduction to the new type of relay

The new relay refers to the electromagnetic relay developed and produced in order to meet the special requirements of the new and meet the use of special environmental conditions, its main characteristics are small size, light weight, vibration resistance, shock resistance, load range from low level load to 5A, 28 V rated load, product ...

Siemens APT Relays - a detailed introduction to the classification of relays Siemens APT Relays - a detailed introduction to the classification of relays

Classified according to the working principle or structural characteristics of relays: 1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature. 2) Solid state relay: refers to the electronic components that perform their functions without mechanical ...

Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There? Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?

There are several types of pushbutton switches: Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...

Siemens APT - AD16 series indicator frequently asked questions Siemens APT - AD16 series indicator frequently asked questions

1. Why does the indicator light still glow after the control power supply has been disconnected? This situation is caused by the presence of interference voltage, and this problem can be solved by ordering our anti-interference indicator light 2. What are the operating hours of the AD16 series indicators? More than 30000 small ...

Siemens APT current transformer – precautions for current transformers Siemens APT current transformer – precautions for current transformers

1. Before the installation of the open current transformer, it must be connected to the meter (or other measuring devices) for the second time to ensure that the transformer is not open for the second time; 2. Place all the open current transformers connected to the secondary line on the site and wait for installation; 3. If the on-site bus is electrical...

What are the main problems with Siemens APT Relays – Solid State Relays? What are the main problems with Siemens APT Relays – Solid State Relays?

When the solid state relay is open and there is voltage at the load end, there will be a certain leakage current at the output end, and care should be taken to prevent electric shock when using or designing. When the solid-state relay fails to be replaced, the original model or the product with the same technical parameters should be selected as far as possible, so as to match the original application line and ensure that the system ...

Siemens APT relay - common faults and solutions for high-voltage relays Siemens APT relay - common faults and solutions for high-voltage relays

1. Poor contact Poor contact is one of the most common faults in high-voltage relays, which can lead to problems such as hot terminals ® and burned contacts. Workarounds include regularly checking terminals and set screws for loose and cleaning contact surfaces. 2. Excessive wear At...

Siemens APT - ALS series limit switch FAQ Siemens APT - ALS series limit switch FAQ

1. What are the installation methods of ALS limit switches? Usually the limit switch is divided into front of the board installation or board back installation, all of which are installed by screws. 2. What are the different modes of limit switch action? According to the action mode of the limit switch head, it is divided into ...

Introduction to the features of Siemens APT DY2 miniature relay Introduction to the features of Siemens APT DY2 miniature relay

Various specifications, with indicator light, with manual test button, with surge suppression loop and other functions Coil control voltage DC6V-220V, AC6V-240V(50/60HZ) The rail type is equipped with a variety of adapting sockets LED indicator, DC is green, AC is red Illuminating...

Siemens APT Relays – The difference between solid state relays and intermediate relays Siemens APT Relays – The difference between solid state relays and intermediate relays

First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life; Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in; ...

Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays

merit 1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.

Siemens APT current transformers – measures to reduce errors Siemens APT current transformers – measures to reduce errors

The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error (1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple. (2) Increase the cross-section of the iron core and shorten the magnetic circuit.

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

Siemens APT relays – classified according to the protection characteristics of the relays Siemens APT relays – classified according to the protection characteristics of the relays

(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium. (2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top