1. What are the current specifications of universal transfer switches?
At present, there are four forms: 10A, 16A, 25A, and 63A
2. What are the positioning angles of the universal transfer switch?
At present, it is divided into four angles: 30°, 45°, 60° and 90°
3. What should I do if there is no customer's demand contact diagram on the sample?
Fill in the contact requirements on the blank contact sheet
4. What are the gear characteristics of the 10,000-turn switch?
Positioning and self-setting
5. Can LW39-16 series be customized to IP65?
Some models can be customized with IP65
6. How many times is the mechanical life of LW39 series 10,000 revolutions?
300,000 times
7. What does LW39-16A 16 mean?
Agree on the heating current
8. How many non-universal keys can be equipped with the YM model?
Up to 100 can be realized
9. How many non-universal keys can be wild-matched with LW39-16C series key type?
Up to 23 can be realized
10. Does the LW39 series have a protective cover?
No, protective covers are not available at this time
11. Do you have any special printing requirements for panels?
You can add a "P" to the model number to define your own special printing requirements
12. What is the wiring method of the light box terminal block with lamp type?
Unless otherwise specified, the default terminal blocks are common negatives: X1 (+), X0 (—), X2 (+). If you need a special wiring method, please indicate it when placing an order.
13. What are the steps to determine the model number?
• Determine the current size and select the series • Determine the gear form and select the positioning feature code • Determine the contact table according to the contact situation • Understand the functional requirements and select the function code • Finalize the complete model "
14. What are the steps to convert the model?
• Similar parameters: heating current • Consistent contact diagram • Similar shape: panel size • Similar functions: standard, key, indicator light • Cut-out size: single, three, five-hole
15. What certifications has my company obtained?
3C and CE certified, of which 16B also has CCS certified
16. Can the 10,000-revolution with light type be used as anti-interference?
OK
17. Can LW390,000 rpm be used as a damp heat type?
Yes, add -TH to the endnote
18. Operating temperature conditions of 10,000 revolutions
-25°C to 55°C
19. What accessories can be ordered separately by MAXIMAN?
The switch handle can be ordered separately, and the key needs to be ordered through the after-sales service
20. Can the LW39 series 10,000 revolutions be used in high altitude areas?
LW39 series 10,000 rpm is used normally at an altitude of no more than 2000 meters.
|
More on that
|
Siemens APT Relays - What are the classifications of high and low voltage relays?
1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the circuit in the input circuit between the electromagnet core and the armature.
2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated. ...
|
|
Siemens APT current transformer – current transformer operating error
When the current transformer is finalized and its internal parameters are determined, the magnitude of the error will be affected by the secondary current (or primary current), secondary load, power factor, and frequency. These factors are called external factors, and the error of the current transformer in operation is mainly affected by these four factors.
...
|
|
Siemens APT Relays – The difference between signal relays and power relays
Signal relays are used more in secondary maintenance circuit circuits. It tells the right people exactly what is wrong with the maintenance. The power relay is a bit like a discriminant sentence in mathematics. When a constant is entered, the satisfactory and unsatisfactory conditions will output different results. Merit...
|
|
Siemens APT current transformer – the basis for whether the current transformer is damaged or the measurement is inaccurate
1. The inspection basis for whether the current transformer is damaged:
1. The basis for checking whether the polarity is damaged:
The primary winding of the current transformer is marked P1 and P2, and the secondary winding is marked as S1 and S2. If P1 and S1 are the same name, then this sign is called reduced polarity. Primary current from P1 ...
|
|
Siemens APT Relays – Classified by relay form factor
(1) Miniature relay: the longest side of the relay is not more than 10 mm.
(2) Ultra-miniature relay: the longest side size is greater than 10 mm, but not more than 25 mm.
(3) Small miniature relay: the longest side size is greater than 25 mm, but not large...
|
|
Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays
merit
1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.
|
|
Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches
Common types of metal button switches include self-locking switches, self-reset switches, knob gear switches, lever gear switches, locking switches, etc.; Because the metal button switch is small in size, easy to install, metal material, voltage can be used from 9-220V, and the appearance of metal texture ...
|
|
Siemens APT Relays – How to Choose the Right Power Relay
1. Measure the resistance of the contact
Use the resistance level of the universal meter to measure the resistance of the normally closed contact and the moving point, and its resistance value should be 0, (the contact resistance value can be measured in a more accurate way within 100 milliohms); The resistance between the normally open contact and the moving point is infinite. From this, it can be distinguished which is a normally closed contact ...
|
|
Siemens apt - TL series police lights frequently asked questions
1. How many light sources are there for the TL-70 police light?
There are 3 types, namely LED, incandescent and xenon.
2. What are the colors of the TL-70 police light?
There are 5 types, which are red, yellow, green, blue, and white.
3. What are the types of TL-70 police lights?
3 ...
|
|
Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?
There are several types of pushbutton switches:
Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...
|
|
Siemens APT Relays – The difference between AC relays and DC relays
1. Structural characteristics of AC relays
The coil of the AC relay is shorter, and the wire diameter is thicker, mainly because the coil is passed through the alternating current, the reactance is larger, and the thick wire diameter can reduce the internal resistance and reduce the heat generation.
|
|
Siemens APT Relays – a commonly used detection method for high and low voltage relays
1. Visual inspection method: observe the appearance of the relay by the naked eye, check whether it is damaged or deformed, observe whether the contacts are tightly contacted, and whether there are copper slag and other substances attached to the contacts.
2. Parameter detection method: use test instruments to detect the parameters of the relay, such as: ...
|
|
Siemens APT current transformers – factors influencing the error of current transformers
(1) The influence of the internal resistance R2 and leakage impedance X2 of the secondary coil on the error: when R2 increases, the specific difference and angular difference increase; As X2 increases, the specific difference increases, but the angular difference decreases. Therefore, to improve the error, R2 and the appropriate X2 value should be minimized. Due to the secondary coil internal resistance R2 and leakage ...
|
|
Siemens APT Relays – What are the functions of relays?
(1) Isolation between input and output circuits;
(2) signal conversion;
(3) Add output circuit;
(4) repetitive signal;
(5) Switch between different voltage or current loads;
(6) Retain the output signal;
(7) Locking circuit;
(8) Provide remote control
...
|
|
Siemens APT current transformer - how to choose a current transformer?
First, the principle of primary parameter selection of current transformer
The rated primary current of the current transformer is determined by the actual load of the tested circuit, and the rated primary current of the current transformer should not be less than the rated primary current of the circuit.
|
|
Introduction to the features of the full range of Siemens APT metal button FM products
Seeking advanced, perfect and excellent Xijia APT to concentrate on research and development, and constantly change customs, the launch of the metal flat button indicator FM series is to complete the perfect integration of appearance and performance.
Ultra-thin flat round device, metal shell and buttons, high-value appearance
Product ...
|
|
Siemens APT helps Tianjin's advanced manufacturing industry
Tianjin is a typical industrial city. Due to the steady progress of "three districts and one base", the advanced manufacturing industry has developed rapidly in recent years. Siemens APT brought a variety of low-voltage control products to the 14th China (Tianjin) International Industry Fair held from March 15-18. Siemens APT has launched the PB1...
|
|
Siemens APT Relays – the solution to common faults in solid state relays
1. The simplest and most effective way is to use a new solid state relay.
2. The other is to determine the voltage of the coil to avoid the voltage provided by the coil being less than the operating voltage.
3. Check whether the polarity is reversed.
4. Reasonable power-on time for the solid state relay coil, if ...
|
|
Siemens APT Relays – The difference between solid state relays and intermediate relays
First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life;
Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in;
...
|
|
AD16-30JC Series Combination Light FAQ
1. What are the basic combination colors of combination lights?
Red, yellow, green, blue, white, bicolor.
2. What are the different types of combination light panes?
F, H, L, V, G any combination
3. Is the lampshade detachable?
OK
4. Combination light ...
|
|