1. What is the maximum voltage that can be used for an ALH transformer?
AC low voltage up to 720V
2. Is there a protective grade product for ALH transformers?
II-P AND III-P are available in both protective grades
3. What is the maximum primary current of ALH transformer?
The maximum primary side current is 8000A
4. Is an open circuit allowed on the secondary side of the transformer?
It is strictly forbidden to open the road on the secondary side
5. What are the common accuracy of the measurement transformers produced by our company? level
There are five levels: 0.2S, 0.5S, 0.2, 0.5, and 1
6. What is the difference between accuracy class with S and without S?
0.5S and 0.2S are generally used for measurement grade, and 0.5 and 0.2 are generally used for measurement grade
7. What is the maximum primary side current that the measurement-grade transformer can detect
1.2 times the rated current
8. What is the implementation standard of our transformer?
The latest national standards GB20840
9. What is the meaning of transformers P1 and P2 and S1 and S2?
P1P2 is the primary polar end, S1S2 is the secondary polar end, and P1S1 and P2S2 are the eponymous ends. Generally, P1+P2-, if P1P2 wiring is reversed, then the corresponding S1S2 is reversed.
10. What altitude can the transformer be used for?
According to GB20840.2-2014, it can be used at an altitude of 1000m, and can be used for capacity reduction above 1000m
11. Will on-site vibration affect the use of the transformer?
According to the national standard, vibrations or minor earthquakes caused by external causes can be ignored
12. Why does the transformer not provide the secondary winding resistance parameter?
It is a confidential parameter and will not be released to the public
13. When the distance between the transformer and the ammeter is long, how to select the transformer?
Calculated according to line distance, ammeter power, transformer capacity
14. What is the insulation grade of the transformer produced by our company?
Meet the requirements of the national standard: E grade, 120°C
15. What are the types of open transformers?
HK NK SK
16. Which type of open current transformer belongs to the fully open and closed structure?
NK
17. What is the aperture coverage of SK series open current transformers?
6——46
18. Which current transformer adopts integrated TVS technology?
SK
19. Which specification of current transformer insulation class B?
SK
20. What is the minimum secondary side current of SK series open current transformer?
2.5mA
|
More on that
|
Siemens APT limit switches – the difference between proximity switches and travel switches
01 The role is different
Proximity switches are contactless switches with a long life and are suitable for "pass-through signals". The travel switch is also known as the limit switch, the travel switch and the limit switch are both position switches, but the travel switch can detect the stroke, and can be used as an input signal to control the circuit at a certain distance ...
|
|
Siemens APT Relays - a detailed introduction to the classification of relays
Classified according to the working principle or structural characteristics of relays:
1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature.
2) Solid state relay: refers to the electronic components that perform their functions without mechanical ...
|
|
Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches
Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.
|
|
Siemens APT Relays – What are the forms of protection relays?
Rail protection relays
A protective relay that works mainly as a result of accidents that occur in transmission lines. When this method works, the circuit breakers at both ends of the faulty line will be disconnected.
Busbar protection relays
A protective relay, mainly due to the power plant or transformer...
|
|
Siemens APT Relays – The difference between solid state relays and intermediate relays
First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life;
Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in;
...
|
|
Siemens APT Relays - Classification and Introduction of Relays
According to the principle of action, it is divided into:
1. The rectifier relay is used in the AC circuit, and its electromagnetic system, contact system and action principle are the same as those of the DC stepless relay.
2. Transistor relay: Transistor relay is composed of transistor transmitter or zero indicator, logic relay, transistor relay.
|
|
Siemens APT current transformer – the basis for whether the current transformer is damaged or the measurement is inaccurate
1. The inspection basis for whether the current transformer is damaged:
1. The basis for checking whether the polarity is damaged:
The primary winding of the current transformer is marked P1 and P2, and the secondary winding is marked as S1 and S2. If P1 and S1 are the same name, then this sign is called reduced polarity. Primary current from P1 ...
|
|
Siemens APT Relays - the main product technical parameters of relays
(1) Rated working voltage: refers to the voltage required by the coil when the relay is working normally. Depending on the type of relay, it can be either AC voltage or DC voltage.
(2) DC resistance: refers to the DC resistance of the coil in the relay, which can be measured by a multimeter.
...
|
|
Siemens apt - TL series police lights frequently asked questions
1. How many light sources are there for the TL-70 police light?
There are 3 types, namely LED, incandescent and xenon.
2. What are the colors of the TL-70 police light?
There are 5 types, which are red, yellow, green, blue, and white.
3. What are the types of TL-70 police lights?
3 ...
|
|
Siemens APT Relays – an introduction to the new type of relay
The new relay refers to the electromagnetic relay developed and produced in order to meet the special requirements of the new and meet the use of special environmental conditions, its main characteristics are small size, light weight, vibration resistance, shock resistance, load range from low level load to 5A, 28 V rated load, product ...
|
|
Siemens APT Relays – The difference between signal relays and power relays
Signal relays are used more in secondary maintenance circuit circuits. It tells the right people exactly what is wrong with the maintenance. The power relay is a bit like a discriminant sentence in mathematics. When a constant is entered, the satisfactory and unsatisfactory conditions will output different results. Merit...
|
|
Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays
merit
1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.
|
|
Siemens APT - ALS series limit switch FAQ
1. What are the installation methods of ALS limit switches?
Usually the limit switch is divided into front of the board installation or board back installation, all of which are installed by screws.
2. What are the different modes of limit switch action?
According to the action mode of the limit switch head, it is divided into ...
|
|
APT made a wonderful appearance at the Northeast Automation Exhibition
On March 31, 2009, the 12th Northeast International Instrumentation and Industrial Automation Exhibition was successfully opened in Shenyang, the industrial hinterland of Northeast China. In recent years, with the national revitalization of the old industrial base in Northeast China and the gradual deepening of the equipment manufacturing industry, the rapid development of Northeast China has provided ...
|
|
Siemens APT relay - the main structural features of high and low voltage relays
1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay.
2. Contact group: The contact group is a high and low voltage relay control ...
|
|
Siemens APT current transformer - working principle and characteristics of current transformer
How a current transformer works
The principle of current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. It has a small number of turns on the primary side winding, stringed in the line where the current needs to be measured, so it often has the full current of the line ...
|
|
Siemens APT relay - the main structural features of high and low voltage relays
1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay.
2. Contact group: The contact group is a high and low voltage relay control ...
|
|
Siemens APT warning light - the role of LED warning light in life
LED warning light function
1. The luminous method selection items are: solid light, shiny, burst flash, constant/shiny mix.
2. The installation base is: L rod, straight rod, folding, and barrel type.
Effect of LED warning light_Effect in different scenes
1. Construction unit
On the road ...
|
|
Siemens APT Relays - What are the common faults of relays?
1. Contact failure
(1) The phenomenon that cannot be disconnected due to mechanical occlusion of the contact (the needle-like protrusion and pit formed on the contact bite each other), fusion welding, or cold welding.
(2) The contact wear of the relay is caused by the absence of arc extinguishing devices or measures, or improper parameter selection, ...
|
|
Siemens APT Relays - High Voltage Relay Fault Causes and Solutions
1. Some common faults of high-voltage relay coils
1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.
2 ...
|
|