Siemens APT transformer - the use of voltage transformer and precautions
The voltage transformer output is usually 100V
1. The working impedance in the secondary circuit of the voltage transformer should not be too small to avoid overload operation.
2 Before connecting the circuit, the polarity of the voltage transformer should be verified.
3 After connecting the circuit, the secondary coil should be reliably grounded, ...
|
|
APT won the 2014 Top Ten Cutting-edge Enterprises in China's Automation Field
On April 22, 2015, the "2015 China Automation Industry Annual Conference and the 10th China Automation Industry Century Event" sponsored by the Chinese Association of Automation was held in Beijing. At the conference, APT won the "2014 Top Ten New Enterprises in China's Automation Field" award, which was awarded by APT last year.
|
|
Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches
Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.
|
|
Siemens APT Relays – Testing of Relays
(1) Measure the resistance of the contact: use the resistance of the multimeter to measure the resistance of the normally closed contact and the moving point, and the resistance value should be 0; The resistance between the normally open contact and the moving point is infinite. From this, it is possible to distinguish which is a normally closed contact and which is normally open.
(2) Coil resistance: multimeter R...
|
|
Siemens APT Relays – Analysis of Common Faults and Causes of Relays
1. Overhaul of the sensing mechanism
For electromagnetic (voltage, current, intermediate) relays, the sensing mechanism is the electromagnetic system. The faults of the electromagnetic system are mainly concentrated in the coil and the moving and static iron cores.
(1) Coil fault maintenance
Coil failure usually has a coil absolute...
|
|
Siemens APT current transformer - how to see the multiple of the current transformer
1. Most of the multiple values can be seen from the nameplate attached to the instrument, which will show the style of the value/value, which can be known by dividing the previous value by dividing the back value when calculating the standard core-piercing turns. If the actual number of turns of the grommet does not conform to the standard, then the multiple should be ...
|
|
Siemens APT current transformer - how to choose a current transformer?
First, the principle of primary parameter selection of current transformer
The rated primary current of the current transformer is determined by the actual load of the tested circuit, and the rated primary current of the current transformer should not be less than the rated primary current of the circuit.
|
|
Siemens APT relay - common faults and solutions for high-voltage relays
1. Poor contact
Poor contact is one of the most common faults in high-voltage relays, which can lead to problems such as hot terminals ® and burned contacts. Workarounds include regularly checking terminals and set screws for loose and cleaning contact surfaces.
2. Excessive wear
At...
|
|
Siemens APT current transformers – measures to reduce errors
The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error
(1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple.
(2) Increase the cross-section of the iron core and shorten the magnetic circuit.
|
|
Siemens APT current transformer - common faults and solutions of current transformers
1. There is an abnormal noise or over-temperature of the iron core
Cause of failure: When the current transformer is in operation, if there is an open circuit or overload in the secondary circuit, it will lead to abnormal sound and over-temperature of the core.
|
|
Siemens APT Relays - What are the classifications of high and low voltage relays?
1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the circuit in the input circuit between the electromagnet core and the armature.
2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated. ...
|
|
Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays
merit
1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.
|
|
Siemens APT Relays – The action of high and low voltage relays and how to adjust the low voltage side
1. Disconnect the control power supply: Before making the low-voltage terminal contact adjustment, the control power supply should be disconnected first to avoid the current directly or indirectly passing through the relay contact, and avoid electric shock or damage to the relay.
2. Open the relay cover: Open the relay cover, you can see the inside of the relay.
|
|
Siemens APT - LW39 series 10,000 revolutions FAQ
1. What are the current specifications of universal transfer switches?
At present, there are four forms: 10A, 16A, 25A, and 63A
2. What are the positioning angles of the universal transfer switch?
At present, it is divided into four angles: 30°, 45°, 60° and 90°
3. There is no customer's ...
|
|
Siemens APT Relays - High Voltage Relay Fault Causes and Solutions
1. Some common faults of high-voltage relay coils
1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.
2 ...
|
|
Siemens APT - x.R series relays frequently asked questions
1. Does the AC control relay have surge suppression?
SR/NR/PR can produce AC with surge suppression circuits
2. How many types of thermal current specifications are there for our company's relays?
3A, 5A, 8A, 10A, 12A five current specifications
3. Surge suppression back ...
|
|
Siemens APT - ALH-0.66 series transformer FAQ
1. What is the maximum voltage that can be used for an ALH transformer?
AC low voltage up to 720V
2. Is there a protective grade product for ALH transformers?
II-P AND III-P are available in both protective grades
3. What is the maximum primary current of ALH transformer?
The maximum primary side current is 8 ...
|
|
Siemens APT Relays – The Cause of Solid State Relays Burnout
1. Poor design (low margin of voltage or current reservation during selection, insufficient heat dissipation conditions, etc.).
2. The fuse is too large or the fast fuse is not used as required.
3. The radiator is full of dust or the cooling fan fails.
4. Solid State Relay ...
|
|
Siemens APT Relays – The Difference Between Solid State Relays and AC Contactors
1. First of all, solid-state relays have a long service life and strong reliability. The solid state relay corresponds to the CDG1 series delicacy. This solid-state relay has no mechanical parts and solid-state devices to complete the contact function. Since the parts do not move, they can work in high shock and vibration environments. Because...
|
|
Siemens APT current transformer – wiring method of current transformer
1. The single wiring mode can only feedback the status of single-phase current.
2. Three-phase complete star wiring, usually used in transformer differential protection wiring.
3. The two-phase incomplete star wiring method is used frequently in daily work.
4. The two phases ...
|