The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. It can be divided into four types according to the different forms of devices, and the appropriate type can be selected according to the controlled motor power and on-site device conditions. One is fixed (wall-mounted), the second is book-mounted, the third is installed/cabinet-mounted, and the fourth is cabinet-mounted.
1. Inverter power is selected according to the load power of the inverter. Choose a frequency converter with a large power for a motor with a high power of the motor. The freshman specifications are also possible.
2. Different types of inverters are used to choose different inverters. For example, there are general-purpose inverters, special inverters for fans and pumps, and inverters for machine tool spindles.
3. If the load inertia is large, the braking unit and braking resistor should be selected together.
4. Check the rated current of the nameplate of the motor, (the rated current is measured when there is no nameplate). The rated current of the inverter is higher than the maximum operating current of the motor.
|
More on that
|
The reason for VFD trip protection - Senlan
In general, there is a problem with the maintenance trip of the VFD. If you look at the faulty code, you can see what kind of fault is causing it.
1. The selection talent of VFD may be too small; Generally, when selecting VFD, it should be about 20% larger than the rated power of the motor, so that when the motor reaches full load...
|
|
Precautions for the selection of exhaust fan inverter - Senlan
1. Whether it has perfect maintenance function
There will be many problems in the production process of the equipment, and if you want to prevent accidents, the equipment must have a perfect maintenance function, so as to prevent the loss of the enterprise. Therefore, when buying an exhaust fan inverter, you need to understand the safety function of the equipment first.
|
|
Servo motor regular diagnosis and repair method - Senlan
1. Common faults of motor heating up too high or smoke motor
Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low;
Overhaul...
|
|
Inverter device inspection and maintenance work steps
1. Preparation process:
Abort the device and admit that the motor is completely aborted.
Press the stop button on the operator panel to stop the operation.
Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that it is indeed disconnected and that it does not ...
|
|
The remote control of the inverter meets the function - Sunland inverter
In general, the long-distance operation of the frequency converter requires the following functions:
1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required.
2) Long-distance start-stop, long-distance start or stop inverter, and ...
|
|
The difference between a voltage signal and a current signal
The general voltage in industry is 0... 5(10)V or current 0(4)... 20mA is used as an analog signal transmission method, and it is also a method often used by program control machines. So what is the difference between the transmission method of voltage and current, and when to choose what method, the following will be briefly introduced.
|
|
The main circuit of the inverter application - Sunland inverter
Between the power supply and the inverter, there is a circuit breaker QF and a communication touch device KM, when the inverter does not have to for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. At the same time, the circuit breaker has maintenance functions such as overcurrent and undervoltage. The main circuit of the inverter can ...
|
|
The difference between "braking" and "parking" of the inverter - Senlan
There are two ways to park a drive.
One way is called "free parking". It is to quickly "power off" the motor, so that the motor can slide and park by its own inertia force (OFF2 parking);
The other way is called "braking parking". So this "brake parking ...
|
|
Senlan low-voltage inverter has four series of applications
1.SB200 fan pump special inverter, widely used in textile, printing and dyeing, washing, cable, packaging, machinery, ceramics, constant pressure water supply, constant temperature control or various OEM.
2.HG1000 high-performance light-load intelligent inverter ...
|
|
Motor inverter principle and precautions for use - Senlan
The difference between a voltage converter and a current converter
Voltage inverter and current inverter are two different operating principles, for example, the operating principle of voltage inverter is mainly to regulate the voltage source, and the voltage source regulates the current to achieve the effect of conditioning, while the current inverter is a direct ...
|
|
Inverter with no-load operation and commissioning - Senlan
(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter.
(2) Set the maximum output frequency and base frequency of the inverter and set the torque characteristics of the motor. Pressure/Frequency (V/F) Operators ...
|
|
Inverter overcurrent protection solution - Senlan
1. Causes of overcurrent
There are many reasons for the occurrence of overcurrent, including soft and hard problems.
1. Causes of soft failures
When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...
|
|
Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line
In order to thoroughly implement the spirit of General Secretary Xi Jinping's important instructions that the economic power must be a maritime power, a shipping power, economic development, a strong country, and transportation, especially shipping, and the implementation of the outline for the construction of a transportation power, the port ship shore power system has become the standard for green ports.
|
|
Inverter protection and braking force issues – Sunland
1. What is regenerative braking?
If the motor decreases the command frequency during operation, the motor becomes an asynchronous generator and works as a brake, which is called regenerative (electrical) braking.
2. Can you get more braking power?
Regenerated from the motor ...
|
|
Wiring specification of inverter control cabinet - Senland
The signal line and the power line must be routed separately: when using the analog signal to remotely control the inverter, the signal line of the control inverter and the strong current circuit (main circuit and sequential control circuit) can be separated from the inverter and other equipment to the analog interference, and the interval should be more than 30cm. Signal ...
|
|
Commonly used motor protection method - Hope Sunland
1. Install a reactor at the output of the inverter: This method is the most commonly used, but it should be noted that this method has a certain effect on shorter cables (less than 30 meters), but sometimes the effect is not ideal.
2. In the inverter ...
|
|
Inverter control scheme for fan and water pump - Senlan inverter
There are many control methods for inverters for fans and pumps, which can be selected according to specific conditions. Here are a few common scenarios.
(1) Manual adjustment This is the simplest control method, that is, the operator instructs according to the instrument, ...
|
|
The difference between soft starter and inverter - Sunland inverter
Soft starter is actually a motor control device with motor soft start, soft stop, light load energy saving and a variety of maintenance functions. First of all, it is a three-opposite parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. By manipulating the conduction of three opposite parallel thyristors ...
|
|
Motor inspection and maintenance, motor problems - Senlan
1: In the operation of the motor, if dust, water stains and other debris enter its interior, it will constitute a short-circuit medium, which can damage the wire insulation layer, form an inter-turn short circuit, increase the current, increase the temperature and incinerate the motor. Therefore, dust, water stains and other debris should be prevented from entering the motor.
|
|
Introduction to the speed regulation mode of inverter motor - Senlan
1. Mechanical speed regulation form
There are three methods of mechanical speed regulation: electromagnetic clutch, hydraulic coupling, and viscous clutch. Among them, the hydraulic coupling device is widely used, that is, a hydraulic coupling device is connected in series between the motor and the load, and the concave and convex liquid level is used to adjust the hydraulic coupling between the motor and the load.
|
|