Robot contactors are noisy?

Cause:

It is likely that the joint contact surface of the contactor is uneven, and the surface is sand or rust. The result will constitute a phase loss, which will lead to the burnout of contactors, switch frequency conversion and other components.

Solution:

The load switch that controls the contactor is lowered, and the manual fast switch contactor is repeated if the sound has not been removed, it needs to be removed and the armature is smoothed, or a new contactor may be replaced.

                                  Failure of robot contactor and inverter - Senland

Robot inverters often report shortcomings?

Cause:

1. The parameter setting is incorrect;

2. Aging of inverter;

3. The water pump is overloaded;

4. Lack of phase;

5. Loose lines.

Solution(s):

Reset the inverter first, and if the same defect occurs from scratch in a short period of time, it is clear that the inverter cannot continue to operate until the operation is removed. The defect code of the inverter is recorded, and the defect is solved according to the clarification book, and the circuit is tightened once, and the three-phase current is measured to see if it is balanced. The lack of phase of the power supply causes the input end of the inverter to burn out, or the inverter is aging, and the inverter needs to be replaced.

More on that
Wiring specification of inverter control cabinet - Senland Wiring specification of inverter control cabinet - Senland

The signal line and the power line must be routed separately: when using the analog signal to remotely control the inverter, the signal line of the control inverter and the strong current circuit (main circuit and sequential control circuit) can be separated from the inverter and other equipment to the analog interference, and the interval should be more than 30cm. Signal ...

The correct wiring of the rail power supply The correct wiring of the rail power supply

The rail-rail power supply is a kind of switching power supply that is installed through the rail-type device, which is mainly used to monitor the voltage, current, temperature and other different aspects of the equipment, so that it can play a good maintenance effect. This switching power supply has a variety of different characteristics such as small size and light weight, ...

Limit switch wiring method - hope Senlan Limit switch wiring method - hope Senlan

Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc. ...

It is hoped that Senlan will become the most powerful shore power solution provider in China It is hoped that Senlan will become the most powerful shore power solution provider in China

Founded in 1998, Hope Lansen is a national high-tech enterprise in the fields of energy conservation and environmental protection, new energy, transmission control and intelligent equipment in China, integrating R&D, manufacturing, system integration and customer service. Its products cover high and low voltage frequency conversion control systems, automated production lines and robot transmission systems.

Inverter heat dissipation treatment in use - Sunland inverter Inverter heat dissipation treatment in use - Sunland inverter

If you want to make the inverter last a long time, you must seriously consider the problem of heat dissipation. Because the failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases exponentially with the increase of temperature. A 10 degree increase in ambient temperature halves the service life of the inverter. Thus...

What are the peripheral equipment for inverter selection - Senlan inverter What are the peripheral equipment for inverter selection - Senlan inverter

After the inverter selection is completed, it is necessary to consider whether other peripheral equipment needs to be equipped according to the actual situation of the site. The peripheral equipment for frequency converter selection mainly includes circuit breakers, reactors, contactors, braking resistors, etc. 1. Circuit breaker ...

Inverter to avoid load shock - Sunland Inverter to avoid load shock - Sunland

In the process of operation, try to ensure that the inverter (hereinafter referred to as -VFD) has a satisfactory acceleration and deceleration time, and the VFD has its own soft start function when starting or accelerating; When the power is shut down or the speed is slowed down, it has the function of soft shutdown. Add acceleration and deceleration times as much as possible within the range promised by the device. When the device requires ...

Can the lower end of the leakage switch be connected to the inverter - Senlan Can the lower end of the leakage switch be connected to the inverter - Senlan

To be able to connect, you must use larger special specifications, the inverter outputs higher harmonics, and the leakage current is larger than that of conventional leakage switches, which simply trip, and requires the use of large-scale or special types of leakage switches. Many VFD manuals have instructions on the installation and selection of leakage switches.

Inverter classification method - Senlan inverter Inverter classification method - Senlan inverter

1. Classified according to the input voltage level According to the input voltage level, the inverter can be divided into low-voltage inverter and high-voltage inverter, and the low-voltage inverter is common in China with single-phase 220 V inverter, three-phase 220 V inverter, and i-phase 380 V inverter. High-voltage inverters are commonly used in 6 kV, 10 kV transformers.

Inverter phenomenon detection method and judgment - Senlan Inverter phenomenon detection method and judgment - Senlan

1. The power-on trip or the main power terminal part of the inverter shows sparks. Disconnect the power cord, check whether the input terminal of the inverter is short-circuited, and check whether the DC side terminals P and N of the central circuit of the inverter are short-circuited. Perhaps the cause is a damaged rectifier or a short circuit in the central circuit. 2 ...

The manufacturing standard of Sunland inverter cabinet The manufacturing standard of Sunland inverter cabinet

Planning specifications: The planning of inverter cabinets should conform to relevant national norms and industry norms, such as GB/T15576-2018 "Low-voltage Distribution Cabinet", GB7251.1-2017 "Low-voltage Complete Switchgear and Control Equipment", etc. Material specifications: The materials of the control cabinet should conform to the relevant codes and regulations.

Inverter parameter setting - Sunland inverter Inverter parameter setting - Sunland inverter

There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of individual parameters in use, so it is necessary to set the relevant parameters correctly. ...

The output side of the inverter is equipped with a contactor - Sunland inverter The output side of the inverter is equipped with a contactor - Sunland inverter

When the power supply and the inverter are replaced, for example, if the inverter has a problem, in order to make an emergency, let the motor be directly changed to be driven by the power frequency power supply; Perhaps the inverter is used for soft starting, and after the motor is accelerated to the power frequency speed, it is changed to be driven by the power frequency power supply. ...

Differential overhaul method of inverter - Senlan Differential overhaul method of inverter - Senlan

For the dual requirements of anti-interference and galvanic isolation, the pre-circuit of the output current detection or voltage detection of the inverter usually uses the "matching" circuit of the linear optocoupler device and the differential amplifier to complete the transmission mission of the detection signal. The circuit of the differential amplifier is based on the current detection circuit ...

Inverter rectifier unit static detection mode Inverter rectifier unit static detection mode

The method of judging the damage of a power element in the rectifier part is to manipulate the single conductivity of the rectifier element, and the positive and negative resistance values should not be consistent when the static value is general, and the specific method is as follows: The three-phase bridge rectifier of the rectifier part may be two...

The main step of inverter debugging - Sunland inverter The main step of inverter debugging - Sunland inverter

Investigation of the function of the inverter system Before debugging the frequency converter, it is necessary to carefully read the operation instructions and related information of the inverter to be debugged to understand the application environment and precautions. Especially before the inverter is energized, it is necessary to carefully observe and see if the inverter has obvious problems.

Motor inspection and maintenance, motor problems - Senlan Motor inspection and maintenance, motor problems - Senlan

1: In the operation of the motor, if dust, water stains and other debris enter its interior, it will constitute a short-circuit medium, which can damage the wire insulation layer, form an inter-turn short circuit, increase the current, increase the temperature and incinerate the motor. Therefore, dust, water stains and other debris should be prevented from entering the motor.

The main circuit of the inverter application - Sunland inverter The main circuit of the inverter application - Sunland inverter

Between the power supply and the inverter, there is a circuit breaker QF and a communication touch device KM, when the inverter does not have to for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. At the same time, the circuit breaker has maintenance functions such as overcurrent and undervoltage. The main circuit of the inverter can ...

Solve the inverter fault method - Sunland inverter Solve the inverter fault method - Sunland inverter

Motherboard faults are often manifested as faults that are difficult to visually identify, such as system startup failure and screen invisibility. You can use a brush to gently brush off the dust on the motherboard, in addition, some plug-in cards and chips on the motherboard are in the form of plugs.

Fault signal processing method of frequency converter Fault signal processing method of frequency converter

(1) Check whether the motor is hot. If the temperature rise of the motor is not high, you should first check whether the size of the load, the acceleration and deceleration time, and the running cycle time are reasonable, and correct the V/F characteristics, and check whether the electronic thermal protection function of the inverter is preset reasonably, such as the inverter.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top