ER. The meaning of the OUE fault code is: overvoltage during standby. The possible reasons are: 1. DC bus voltage detection circuit failure; 2. The input voltage is abnormal or the power is lost during operation. It can detect whether the power supply voltage used by the inverter is normal, and in addition, it is necessary to check whether the power supply line of the inverter is normal and whether the wiring is OK.
1. Overvoltage
Overvoltage is a fault that will be encountered in the use of the inverter, and the inverter will give the fault code when the fault occurs. The so-called overvoltage of the inverter refers to the inverter voltage that exceeds the rated voltage due to various reasons, which is manifested in the DC voltage of the DC bus of the inverter, which is divided into accelerated overvoltage, deceleration overvoltage and constant speed overvoltage.
2. Reasons
The causes of inverter overvoltage faults are:
1. The input voltage is too high: as long as the parameters are set correctly, the general power supply voltage will not trip the inverter due to overvoltage. The overvoltage on the input side of the power supply mainly refers to the impulse overvoltage on the power supply side, such as the overvoltage caused by lightning and the overvoltage caused by the compensation capacitor when it is closed or disconnected. These situations can be solved by means of parallel surge absorbers or series reactors on the input side.
2. The regeneration overvoltage caused by the operation of the motor dragged by external force: I think so, in the process of motor operation, the actual speed of the motor is higher than the command speed of the inverter, and the motor is in the state of regenerative power generation. In this case, a braking unit (built-in in some inverters, which can be checked and explained) and a braking resistor can be installed.
3. Inverter hardware problems: The internal detection components of the inverter can only be sent for professional repair.
|
More on that
|
Inverter-related knowledge - Senlan inverter
1. What does open-loop mean in the use of inverters?
The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...
|
|
Advantages of Sunland HOPE530 series inverter
Sunland HOPE530 series inverter is a high-performance, high-reliability intelligent controller, widely used in a variety of industrial occasions. It is easy to operate, diversified equipment and high quality, and has become one of the intelligent power control equipment trusted by users.
...
|
|
There is a problem with the inverter-controlled motor pressing the stop button
What happens when the inverter-controlled motor presses the abort button, and the motor is not controlled to speed up?
1. If it is a newly installed inverter, it is generally necessary to consider the wiring problem, you can first change the parameters to switch to the panel control, the panel is given the frequency, and then see if the inverter operation will appear in this ...
|
|
Rapid selection method of low-voltage inverter - Sunland inverter
First, according to the classification and selection of inverters
1. Inverters can be divided into general-purpose inverters and special inverters.
2. General-purpose inverters are mainly used in: general fan pumps (referring to inverters that only drag a single fan or pump) loads, mechanical loads, and loads requiring high overloads.
|
|
The control performance standard of the inverter cabinet
The control specifications of the inverter cabinet include reliability, accuracy, safety, environmental habits and versatility, etc., which are important guarantees to ensure the normal operation and safe production of the inverter cabinet control system.
Reliability specification: The control system should have high reliability and can be used for a long time.
|
|
Sunland - inverter operation process and factory value restoration
The general operation process is as follows:
Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, the no-load power on test run and ...
|
|
Inverter heat dissipation treatment in use - Sunland inverter
If you want to make the inverter last a long time, you must seriously consider the problem of heat dissipation. Because the failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases exponentially with the increase of temperature. A 10 degree increase in ambient temperature halves the service life of the inverter. Thus...
|
|
I/O (Input/Output) Selection – Senland
In the 90s of the 20th century, PLC has formed a variety of PLCs: micro, small, medium, large and giant. According to the number of I/O points, it can be divided into five types: micro PLC (32 I/O), small PLC (256 I/O), medium PLC (1024 I/O), large PLC (4.69 I/O), and giant PLC (8195 I/O).
...
|
|
Limit switch wiring method - hope Senlan
Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc.
...
|
|
The basic requirements of VFD installation design - Sunland inverter
(1) The VFD should be installed in the control cabinet.
(2) The VFD is best installed in the center of the control cabinet; The VFD It should be vertically installed with the top and bottom protected from large parts that may obstruct the exhaust and intake.
(3) VFD control cabinet or partition, or the upper and lower parts of the necessary device ...
|
|
Inverter interference solution - Sunland inverter
1. Make proper grounding
After a detailed investigation of the site, we can see that the grounding situation on the site is not very ambitious. The correct grounding can not only be useful for the system to press the external disturbance, but also to reduce the disturbance of the equipment itself to the outside world, which is the most useful for dealing with the disturbance of the inverter.
|
|
The device inside the inverter that needs to be replaced regularly - Sunland
1. Cooling fan
As a prerequisite to ensure the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.
|
|
Inverter overcurrent treatment method - Senlan inverter
Overcurrent or overload of the inverter is a common problem of the inverter, and overcurrent refers to the value of the current flowing through the inverter beyond its additional range.
1. If the power supply of the inverter is out of phase, the circuit at the output end is disconnected or the motor winding ...
|
|
Inverter load type - Sunland inverter
(1). Constant torque load
Different speeds, load resistance and torque base are stable. The output power is directly proportional to the rotational speed. Such as belt conveyors.
(2). Constant power load
Different speeds, stable load power base ...
|
|
At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter
For the most popular electrical control equipment inverter (Variable-frequency Drive, VFD), as a precision electronic industrial control equipment, in order to run smoothly for a long time, we, as professional and technical personnel, need to be on the VFD device or before the operation.
|
|
Ensure the normal operation of the inverter in a humid environment
Due to the heavy rain and humidity in some areas recently, in order to avoid long-term power failure and the impact of wetting on the inverter, the following points can be used as various precautions before customers resume production:
1. Look inside the electrical cabinet, e.g. ...
|
|
Precautions for using inverter - Sunland inverter
A frequency converter (VFD) is an electrical energy control device that converts a power supply to another frequency by using the on-off effect of power semiconductor equipment. It can realize the soft start, frequency conversion speed regulation, improved operation accuracy, power factor, overcurrent/overvoltage/overload protection of AC asynchronous motor, etc.
|
|
Energy-saving operation method of air compressor inverter - Senland
At present, the domestic air compressor market takes the goal of energy saving, environmental protection and cost reduction as the primary demand, and the new products developed are very popular. However, economically speaking, it cannot completely replace the conventional screw air compressor with large area and large capacity in use. Therefore, the use of inverter technology to ...
|
|
Motor starting mode - Senlan inverter
The inverter is a motor control (speed regulation) device that uses the on-off effect of power semiconductor devices to convert the power frequency power supply to another frequency.
Composition 1:
1. Rectifier unit: convert the communication electricity with fixed operating frequency into DC ...
|
|
Sunland low-voltage inverter division series
1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge, dehydrator, sewage treatment, HVAC, constant pressure water supply, constant temperature control, flow control and other industries, such as fans and pumps, ...
|
|