The programming philosophy is different
Mitsubishi PLC is a Japanese brand, programming is intuitive and easy to understand, and it will be easier to learn, while Siemens PLC is a Germany brand, the instructions are more general, it is more difficult to learn, but there are fewer instructions, and Mitsubishi has more instructions, so the cycle of learning Mitsubishi and learning Siemens is the same.
Mitsubishi's advantage
Discrete control and motion control, Mitsubishi's instructions are abundant, there are special positioning instructions, control servo and stepping are easy to complete, to complete some messy action control is also Mitsubishi's strength, and Siemens is weaker in this area, there is no special instruction, do servo or step positioning control is not can not be completed, but the program is chaotic, and the control accuracy is not as good as Mitsubishi.
Process control and communication control Siemens is a strong point, Siemens' analog module is cheap and the program is simple, while Mitsubishi's analog module is expensive and the program is messy, Siemens is also easy to communicate, the program is simple, and Mitsubishi has a weak function in this area. Therefore, for different equipment and different control methods, we must reasonably choose PLC, use its benefits, and avoid its shortcomings. For example, if a device is only controlled by some actions, such as a manipulator, Mitsubishi's PLC can be selected, and if a device has a servo or stepper to be positionally controlled, Mitsubishi's PLC can also be selected; Like central air conditioning, sewage treatment, temperature control, etc., there are many analog quantities to be processed, it is more appropriate to choose Siemens' PLC, and there are many instrument data to be collected by communication on the site of a certain equipment, and Siemens' good control is chosen. The difference is very large. The chips are definitely different (reflected in the capacity and computing speed), but the biggest difference is still reflected in the programming software.
Ideas and structures
Personally, I think that the software of Mitsubishi (a Japanese mid-to-high-end brand) PLC is at least 5 years behind Siemens. Putting aside the large and medium-sized ones, let's compare Mitsubishi's relatively advantageous small machine FX series with the Siemens S7-200 series.
PLCs of the Mitsubishi series
Mitsubishi PLC, also known as Mitsubish Power Line Communication, is the main product produced by Mitsubishi Electric in Dalian. Mitsubishi PLC is common in the Chinese market with the following models: FR-FX1N FR-FX1S FR-FX2N FR-FX3U FR-FX2NC FR-A FR-Q FX1S series: Mitsubishi PLC is an integrated small unit PLC. And it has intact functions and communication functions and other scalability. If you consider the space and cost of the installation, it is an ideal choice.
The X1N series is Mitsubishi Electric's powerful and popular PLC. It has the scalability of extended input and output, analog control and communication, link function, etc. It is a Mitsubishi PLC that is widely used in general sequential operation.
FX2N Series: Mitsubishi PLC is the most advanced series in the FX family. With high-speed processing and the ability to expand many special function modules to meet individual needs, it provides the most flexibility and control ability for factory automation applications.
FX3U: It is a new third-generation Mitsubishi PLC recently launched by Mitsubishi Electric Corporation, which may be called a small *** product.
The fundamental function has been greatly improved, and the fundamental unit of the transistor output type has a built-in 3-axis independent positioning function with a height of 100kHz, and a new positioning command has been added, so as to make the positioning control function stronger and more convenient to use.
FX1NC FX2NCFX3UC Mitsubishi PLC: Significant downsizing I/O type wiring interface reduces wiring costs and saves time.
Q Series Mitsubishi PLC: Mitsubishi Machinery Corporation launched a large PLC, CPU types include basic CPU, high utility CPU, process control CPU, motion control CPU, redundant CPU, etc. Able to meet all kinds of messy control needs. With the rapid development of Mitsubishi Electric's work in China, in order to better meet the requirements of domestic users for the high function and low cost of Mitsubishi PLC and Q series products, Mitsubishi Electric Automation has launched an economical QUTESET type Mitsubishi PLC, that is, a 5-slot Q00JCOUSET with a 64-point high-density hybrid unit; The other 8-slot Q00JCPU-S8SET, which comes with 2 16-point switching inputs and 2 16-point switching outputs, is fully compatible with Q00J and fully supports GX-Developer and other software, so it has the best cost performance.
A-Series Mitsubishi PLC: Using Mitsubishi's dedicated sequential control chip (MSP), the speed/command is comparable to that of large Mitsubishi
PLC; A2ASCPU Supports 32 PID circuits. The number of loops of QnASCPU is unlimited and can be changed with the size of the memory. The program capacity is from 8K steps to 124K steps, and the memory capacity of QnASCPU can be expanded to 2M bytes if memory cards are used. There are a variety of special modules to choose from, including network, positioning control, high-speed counting, temperature control and other modules.
PLCs from the Siemens series
SIEMENS AG FWB: SIE, NYSE: SI is one of the world's largest electromechanical companies, founded in 1847 by Werner von Siemens. The advantages of our SIAMTIC modular controllers are their out-of-the-box use, long-term compatibility and availability, their ability to operate in harsh environments, and the ability to expand and upgrade their modules. Our products are very sensation-resistant and are controlled by centralized and distributed I/O. Therefore, Siemens has been able to enter China's market very effectively in recent years, and can firmly take root in China's market. This has a great relationship with the quality and functionality of Siemens products. Among them are the S7-200, S7-300, S7-400.
The S7-200 is suitable for the manufacture of a range of machines or as a stand-alone solution, as part of a micro-automation system, and the STEP 7 Micro/WIN engineering software is used for automation missions with low functional requirements.
It is a low-cost miniature system. The Siemens S7-300 is a fail-safe type with its compact design, mounted on a DIN rail, integrated into the CPU, maintenance-free by insisting on data on micro memory, and isochronous form on PROFIBUS. The Siemens S7-400 has a rack system with a variety of rack types, excellent high-speed processing and communication functions, the ability to change configurations during operation, the isochronous form on PROFIBUS (Figure 1), and the support for PROFIBUS to connect distributed I/O (Figure 2), which is a fail-safe and fault-tolerant type, and hot-swappable. The S7-400's three H CPUs support hardware synchronization, a robust solution that does not cause any loss of information, and can provide excellent support for engineering missions without additional programming costs, enabling easy expansion of the H system for security applications.
Siemens plc now not only fully uses 16-bit, 32-bit high-function microprocessors, high-function chip microprocessors, RISC (reduced instruction set computer) reduced instruction system CPUs and other *** CPUs, but also configures multiple microprocessors in a PLC for multi-channel processing, and produces a lot of intelligent modules containing microprocessors, making the fourth-generation PLC products become a logic control function, process control function, A veritable multi-function manipulator for motion control function, data processing function, and network communication function.
|
More on that
|
Mitsubishi Electric Solutions serves the entire process of lithium battery production
Mitsubishi Electric's MES system MELNAVI has a standard database, which can meet the needs of the 11 major functions required by MES, and also supports flexible secondary development, which can easily connect the upper ERP and lower automation products in a short time, and can also be connected to other APS scheduling software and analysis systems. ...
|
|
Introduction to the functions of Mitsubishi's commonly used servo motor series
Mitsubishi servo motor MR-J2S series
1. The product also has RS-232 and RS-422 serial communication function, which can be used for parameter setting, trial operation, status display and gain adjustment through the personal computer installed with servo setting software.
2. Matching with MR-J2S series ...
|
|
Mitsubishi garbage incinerator equipment with a daily processing capacity of 1,500 tons was delivered and put into operation
Mitsubishi Heavy Industries Environmental & Chemical Engineering Co., Ltd. (MHIEC, President: Takayuki Hishinuma, Headquarters: Nishi-ku, Yokohama), a subsidiary of the Mitsubishi Heavy Industries Group, has supplied two advanced Mitsubishi grate furnaces to a large-scale waste-fired power plant in Xiaogan City, Hubei Province, China. The waste-fired power generation ...
|
|
The connection of the Mitsubishi inverter FR-A800
The connection of the Mitsubishi inverter FR-A800
|
|
What is the difference between the Mitsubishi PLC FX3U and FX5U
1. The speed of the system bus is different. Although the FX5U series is small but precise, compared with the previous product FX3U, the system bus speed is greatly increased by 150 times, and the maximum expansion module can be expanded by 16 intelligent expansion modules, built-in 2-in and 1-out analog functions, built-in Ethernet interface and 4-axis 200kHz high-speed positioning function.
...
|
|
Mitsubishi PLC and computer communication setup method
After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings".
1. Connect the Mitsubishi PLC to the computer first.
2. Right-click on "My Computer" and select "Handle"...
|
|
Special function module of the Mitsubishi PLC FX series
The communication module of PLC is used to complete the communication with other PLCs, other intelligent control equipment or computers. The following is a brief introduction to the FX series communication function shields, adapters and communication modules.
(1) Communication expansion ...
|
|
Mitsubishi FR-A840 series inverter is coming "strong".
Mitsubishi Electric Automation Corporation has launched the A800 Series Integrated Inverter Drive (VFD) for fast, reliable, easy-to-use, and easy integration and installation for occupational demand drives. The A800 series variable frequency drive combines traditional induction and permanent magnet vehicles into a single solution that supplies ...
|
|
The choice of industrial tablet case – Mitsubishi
Tablet PC can often be seen in today's daily life, it can be brought stronger, but also more popular with us, industrial tablet PC is gradually widespread, because industrial use will cause Tablet PC is very simple damage, so generally will use maintenance covers, so ...
|
|
Mitsubishi inverter OC causes the failure
1. The ERR problem is an under-voltage problem, which is usually caused by the problem of voltage detection loop resistance or wiring, rather than the actual input voltage showing undervoltage. Most of the OC problems of the A200 series are caused by the damage of the drive circuit, and its drive circuit ...
|
|
PLC circuit debugging precautions - Mitsubishi
1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the state; The positive logic criterion is usually used, that is, when the input and output are live, it is in the "ON" state and the data value is "1"; Conversely, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...
|
|
Mitsubishi PLC's six programming languages
(1) Ladder diagram
Programming language is traditionally called a ladder diagram. The ladder diagram follows the method of relay control circuit, and it can also be said that the ladder programming language is simplified from the symbol evolution on the basis of the logic control of relays and contactors commonly used in electrical control systems.
|
|
The relationship between torque and performance of Mitsubishi servo motors
1. Additional torque
The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor.
2. Starting torque
The torque generated by the motor at the moment when a voltage is applied to the motor in a stopped condition is called the starting torque. The starting torque characterizes the electrical...
|
|
Mitsubishi PLCFX3U positioning control
Origin regression command with DOG lookup function
Mitsubishi PLCFX3U origin regression command with DOG lookup function: DSZR.
1. The workbench runs in the direction of the value reduction of the current value register (generally runs in the opposite direction M8342 ...
|
|
Mitsubishi Q Series PLC and GX Works2 connection method
01 USB connection
USB connection requires a device USB driver, generally after installing GX Works2 software, it will automatically install the driver, but a single time due to antivirus software or system reasons, may not be installed, then we need to manually drive the device to the accounting machine. The specific device method we ...
|
|
The difference between Mitsubishi PLC source type and leak type
Mitsubishi PLC split source type (PNP) or drain type (NPN), here are their differences
1: Leakage logic: When the current flows out of the signal input terminal, the signal becomes ON, which is leakage logic. The current flows through the terminals and has the output characteristics of an NPN transistor.
2: Source logic: When ...
|
|
Mitsubishi Electric develops satellites for greenhouse gas and water cycle observations
TOKYO, March 30, 2020 – Mitsubishi Electric Corporation (Tokyo: 6503) announced today that it has been appointed by the Japan Aerospace Agency (JAXA) as the contractor for the Global Satellite Observing Satellite for the Greenhouse Gas and Water Cycle (GOSAT-GW), the third satellite in the GOSAT series, ...
|
|
Mitsubishi PLC and inverter are communication methods
The output point and COM point of PLC (MR type or MT type) are directly related to the STF (forward rotation engine) of the inverter. overflow-wrap: break-word !important; ">. RH (high speed), RM (medium speed) important; overflow-wrap: break-word !important; ">、R ...
|
|
Mitsubishi Electric MPD series IGBT modules
Mitsubishi Electric's newly developed new MPD series IGBT modules will be unveiled at PCIM Asia 2012 (BoothNo). :301) June 19-21 at the Shanghai World Expo Complex. The new MPD series is very suitable for water-cooled design, and is a high-current power supply with good heat dissipation performance and strong reliability.
|
|
Mitsubishi PLC login password setting operation
Method 1
1. Hit the PLC from RUN to STOP
Mitsubishi's PLC has a special method of setting landing keywords, and it is necessary to ensure that the PLC is in a state of shutdown in order to successfully write the landing keywords.
In the run running condition, the performance of the write will appear "Unable to ...
|
|