1. The ERR problem is an under-voltage problem, which is usually caused by the problem of voltage detection loop resistance or wiring, rather than the actual input voltage showing undervoltage. Most of the OC problems of the A200 series are caused by the damage of the drive circuit, and its drive circuit uses a thick film circuit with a ceramic package, which brings certain difficulties to maintenance, and its thick film circuit is mainly based on a circuit planned to drive the optocoupler.
2. Aging of the drive circuit
Because the use of a long period of time will inevitably lead to the aging of the components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so the OC alarm is often displayed as soon as it is operated.
3. The damage of the IPM module will also cause OC alarm
The power module used in the Z024 series equipment not only contains over-current, under-voltage and other detection circuits, but also contains an enlarged drive circuit, so it is not necessary to detect the damage of the circuit or the damage of the drive circuit.
As well as damage to high-power transistors, OC alarms may occur.
4. Most of the reasons for the lack of display problems are caused by the damage of the thick film of the switching power supply.
5. In addition, there will be some LV problems, and the undervoltage problem is also eighty percent because of the bus detection circuit problems, Mitsubishi inverter has also planned a thick film circuit for detecting voltage and current. The damage of the switching power supply pulse transformer is also a common problem of A200 series frequency converters, because of the short circuit of the switching power supply output load, or the sudden change of bus voltage, resulting in the damage of the primary and secondary windings of the pulse transformer.
|
More on that
|
Mitsubishi servo maintenance failure analysis
Major Failures and Analysis:
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
...
|
|
Mitsubishi inverter control mode
According to the classification of the main circuit operation mode, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
According to the classification of operating principles, it can be divided into V/f control frequency conversion ...
|
|
Mitsubishi inverter FR-E700 series is selected
Q: When will I choose the E740 series inverter?
A: E700 is an economical and small inverter with high driving performance, with the function of holding the brake, and can also add options to expand the function, which can be used for transportation, lifting occupations, and has high cost performance.
Q: Mitsubishi inverter E740 should ...
|
|
Mitsubishi PLC advantages
Discrete control and motion control, Mitsubishi's instructions are abundant, there are dedicated positioning instructions, control servo and stepping are easy to complete, to complete some messy action control is also Mitsubishi's strength, and Siemens is weaker in this area, there is no special instruction, do servo or step positioning control is not ...
|
|
Mitsubishi drive fault codes
1. If the problem code E.OC1 is displayed on the screen of the Mitsubishi inverter, it means that the overcurrent may speed up the operation when the inverter is accelerating. We need to check whether the output of the inverter is short-circuited and whether the main power supply is operating normally;
...
|
|
Review and comparison of Mitsubishi PLC control inverter methods
1. The switching signal of PLC controls the inverter
The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and input SG ports of the inverter. The PLC can be programmed to control the inverter's start, ...
|
|
Mitsubishi servo motor is now commonly used
Torque control: Torque control is based on external simulation imitation typing or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load of the motor shaft is less than 2.5Nm, then when ...
|
|
Anti-interference measures for PLCs and touch screens - Mitsubishi PLC
1. Select the power supply with excellent performance and press the disturbance introduced by the power grid
The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Isolation transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in isolation...
|
|
Mitsubishi PLC control system electroplating production line design
Planning PLC control system control requirements for electroplating production line:
1) SQ1-SQ4 is the driving advance and retreat limit switch, and SQ5-SQ6 is the upper and lower limit switches.
2) The workpiece is lifted to SQ5 to stop, and the car is driven to SQ1 to stop.
|
|
Mitsubishi Step Ladder Instruction [STL], [RET] usage example
Step Instruction (STL) is an instruction that uses internal software components to control the process step on top of the sequential control program. A step-to-back instruction (RET) is an instruction that is used to return to the main program (bus) after the state (S) process is completed.
...
|
|
Mitsubishi Electric will introduce the T-series 2.0kV IGBT module for industrial use
Tokyo, June 9, 2021 – Mitsubishi announced the upcoming launch of its industrial T-series 2.0kV insulated gate bipolar transistor (IGBT) module, the world's first IGBT1 with a 2.0kV withstand voltage, June 30. This module is ideally suited to increase the power of renewable energy power converters ...
|
|
Mitsubishi AnS series analog module bias and gain applications
In today's industrial field, when using analog-to-digital conversion or digital-to-analog conversion, most of them do not only use the standard input characteristics of -10V-+10V, 0-20mA, but according to the practical voltage and current values to do the process requirements, then it is necessary to do the AD or DA module ...
|
|
PLC Reasonable Programming to Eliminate Misoperation - Mitsubishi
(1) Eliminate finger tremor: use the differential instruction DIFU (13) to retrieve the rising edge of the button to send the electrical signal, and the PLC only executes it once in an execution cycle, and then prevent such misoperation;
(2) Unconscious operation:
(1) Optimize the display function and use different fingers...
|
|
Mitsubishi Electric appeared at the 2021 China Smart Expo
From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...
|
|
Query Error Code Method – Mitsubishi
Error Number (D8063): 6314
ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL)
Error content: Parallel operation string abnormal
Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...
|
|
Self-locking function of servo motor - Mitsubishi
Press the abort button SB1, the contactor KM coil is de-energized, and the auxiliary normally open contact of the KM connected in parallel with SB2 is disconnected to ensure that the KM coil continues to lose power after the button SB1 is released, and the main contact of the KM connected in series in the motor circuit is continuously disconnected and the motor stops. Auxiliary to the KM in parallel with SB2 ...
|
|
Mitsubishi PLC program lost backup program write method
The reasons for the loss of the PLC program are the lack of battery power supply for the user's saved program, the internal circuit of the PC, the motherboard burned out due to the impact of external high voltage such as lightning strikes, etc., which will be encountered in our PLC control system. For example, the old type of plc such as the FX2N series, which has been discontinued...
|
|
An introduction to the types of data inside the Mitsubishi FX series
A lot of data is used in the internal structure of the PLC and in the user's use program. These data have the following forms in terms of structure or number system.
(1) Decimal number
Decimal numbers are also known as word data in PLC. It is first and foremost ...
|
|
The impact of Mitsubishi inverters on the quality of the power grid
In the case of impact loads such as electric welding machines, electric arc furnaces, rolling mills, etc., the voltage often flickers; In a workshop, when there are multiple Mitsubishi inverters and other capacitive rectifier loads working, the harmonics that occur are very serious pollution about the quality of the power grid, and there is also considerable damage to the equipment itself.
|
|
Mitsubishi PLC controls the servo motor through a touch screen
The Mitsubishi PLCFX3U-48MT-ES-A is used as the control element, and the Mitsubishi touch screen GT1155-QFBD-C is used as the operating element to directly control the specific program design of the Mitsubishi servo motor.
First, the selection of components in the control system
1. Selection of PLC
In the application of Mitsubishi servo drive ...
|
|