Mitsubishi Electric Automation Corporation has launched the A800 Series Integrated Inverter Drive (VFD) for fast, reliable, easy-to-use, and easy integration and installation for occupational demand drives. The A800 series inverter drives combine traditional induction and permanent magnet vehicles into a single solution, providing highly functional response and energy-efficient motor control.
The A800 meets the growing demand for multi-functional inverters for original equipment manufacturers (OEMs), end users and system integrators. It can be used in induction motors and next-generation indoor permanent automobiles and is suitable for both low-function use such as pumps and fans, as well as high-performance industrial use.
Mitsubishi FR-A840 series inverters are suitable as hydraulic drive systems and replacement gear motors for process and data processing occupations, and replacement of inefficient motor drive systems in food and beverage occupations. It is also expected to complete the high adoption of automobiles, oil and gas, forestry products and industrial wastewater. The A800 is suitable for any motor control program that increases motor power and maximizes energy savings.
The Mitsubishi A800 series is available in traditional chassis style, large system/component style, and fully enclosed, harsh environment style configuration. Mitsubishi Electric Automation offers a comprehensive range of factory automation products and solutions.
|
More on that
|
Mitsubishi PLC commonly used circuit programming application
1. Self-locking and interlocking circuits
1) Self-locking circuit: The self-locking circuit is often used for the start-stop control of the motor.
Press the start button X0 motor to start running, release the start button to keep the motor running, press the stop button X1 motor to stop running.
2) Interlock ...
|
|
Mitsubishi servo system selection
Mitsubishi servo system mainly has MR-J4, MR-JE, MR-JE-AS and other series, MR-J2S, MR-J3, MR-ES has been discontinued, gradually withdrawn from the shopping mall, the first three are considered.
When selecting a Mitsubishi servo, the first thing is to choose the MR-J4 series or MR-JE series according to the application, and the driver uses the A-type ...
|
|
Characteristics of servos and advantages of Mitsubishi servos
The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.
|
|
Mitsubishi touch screen GT10 series models and their features
GT1020 touch screen
● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches
●3-color LED backlight for added visibility
●High brightness liquid crystal, clear under light
● Resolution 160×64, standard memory 512K
●Inside ...
|
|
Mitsubishi servo motor is now commonly used
Torque control: Torque control is based on external simulation imitation typing or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load of the motor shaft is less than 2.5Nm, then when ...
|
|
Introduction to the functions of Mitsubishi's commonly used servo motor series
Mitsubishi servo motor MR-J2S series
1. The product also has RS-232 and RS-422 serial communication function, which can be used for parameter setting, trial operation, status display and gain adjustment through the personal computer installed with servo setting software.
2. Matching with MR-J2S series ...
|
|
Mitsubishi's introduction to the three-circuit system
Servo motors are generally operated by three circuits. To put it bluntly, the three circuits are three closed-loop control negative feedback PID control systems.
The first innermost PID loop is the current loop, which is implemented completely inside the servo controller. Exercise...
|
|
Mitsubishi inverter fault judgment method
1. UVT problem
UVT is an under-voltage problem, and I believe that many customers will still encounter such problems in use.
The common undervoltage detection point of Mitsubishi inverter is the voltage on the DC bus side, and a low voltage value is sampled after the voltage division of the large resistance resistor, which is compared with the standard voltage value ...
|
|
Mitsubishi 30MA-eX-F40 fiber laser flexible automatic loading and unloading system
The 30MA-eX-F40 fiber laser flexible active loading and unloading system was jointly developed by Mitsubishi Electric Corporation's Laser Division and Mitsubishi Electric Electromechanical Technology Co., Ltd.
...
|
|
Mitsubishi inverter E6 and E7 are faulty
E6, E7 fault for the majority of users must not be unfamiliar, this is a more common Mitsubishi inverter typical problem, of course, the cause of damage is also multifaceted.
IC 1302H02 is damaged, which is a piece of integrated drive ...
|
|
Mitsubishi PLC commonly used model features
FX Series PLC: The FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in standard mode. In the meantime, the FX series 5U is suitable for any industry, and is widely used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...
|
|
Mitsubishi servo selection robot method
When evaluating which process is suitable for which process to use in the production environment, it is necessary to carefully consider the problem you want to solve and consider all the costs that the robot can save: reduce waste, improve power, improve yield, improve safety or reduce labor costs. These costs ...
|
|
Precautions for the use of Mitsubishi servo motor with brake
1. Occasions with brake servo motors:
The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...
|
|
Mitsubishi Inverter F740 restores factory default
Press the "SET" button to end the factory setting.
Defects usually occur due to problems with the resistors or wiring of the voltage detection loop, rather than the actual undervoltage of the input voltage. OC disadvantages of the A200 series ...
|
|
PLC controller and human-machine interface anti-interference countermeasures - Mitsubishi
When carrying out anti-disturbance planning for specific projects, it is necessary to select products with high anti-disturbance ability, and adopt methods such as pressing the disturbance source, cutting off or attenuating the propagation path of electromagnetic disturbance, and using software means to improve the anti-disturbance ability of equipment and systems.
...
|
|
The weight conversion method of the Mitsubishi weigh module
Component conversion is a process in which an analog signal (load converter output voltage) input from outside the programmable controller is converted into a digital output value and a total component output value, and then stored in buffer memory. After the conversion process, the conversion completion (XE) will change to ON, and the transformation completion mark (Un\G1 ...
|
|
Mitsubishi PLC and computer communication setup method
After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings".
1. Connect the Mitsubishi PLC to the computer first.
2. Right-click on "My Computer" and select "Handle"...
|
|
What are the main factors of interference in Mitsubishi PLC system?
(1) Radiative dry disturbance from space
The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...
|
|
Built-in time adjustment in Mitsubishi PLC
How do I adjust the built-in moments in my Mitsubishi PLC? In the case of Mitsubishi PLC, sometimes technical engineers forget to adjust the PLC well, but they also need to pay attention to some key points and introduce how to adjust the built-in moments in Mitsubishi PLC.
...
|
|
Mitsubishi servo motor method
1. Torque control: Torque control sets the output torque of the motor shaft through external imitation input or direct address assignment. For example, 10V is equivalent to 5Nm. When the external analog is set to 5V, the output of the motor shaft is 2.5 Nm. If the motor shaft load is less than 2.5 Nm, when the external load is 2.5 N...
|
|