Introduction to the functions of Mitsubishi's commonly used servo motor series

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

Mitsubishi servo motor MR-J2S series

1. The product also has RS-232 and RS-422 serial communication function, which can be used for parameter setting, trial operation, status display and gain adjustment through the personal computer installed with servo setting software.

2. The servo motor encoder matched with MR-J2S series adopts an absolute position encoder with a resolution of 131072 pulse/revolution, so it has the ability to carry out higher precision control than MR-J2 series, and adopts high-performance CPU, which greatly improves the responsiveness of the product, and the frequency response of the speed loop is increased to 550HZ.

3. A variety of series of servo motors adapt to different control needs, the encoder on the motor supports ABS mode, as long as the servo amplifier is added with another battery, it can constitute an absolute position system.

4. It is more convenient to use, with excellent automatic tuning performance, mechanical analysis function, can easily suppress mechanical vibration, gain search function, and can automatically find out the best gain value.

                                  Introduction to the functions of Mitsubishi's commonly used servo motor series

Mitsubishi servo motor MR-J3 series

1. The product has USB and RS-422 serial communication functions, through the installation of servo setting software of the personal computer can be parameter setting, trial operation, status display monitoring and gain adjustment and other operations, the product has a high level of self-tuning function and advanced vibration suppression control function.

2. The high-performance servo motor encoder matched with MR-J3 series adopts an absolute position encoder with a resolution of 262144 pulse/revolution, and the frequency response of the speed loop is increased to 900HZ, which has the characteristics of high speed/large torque, so it has the ability to carry out higher precision control than MR-J2S series.

3. A variety of series of servo motors adapt to different control needs, the encoder on the motor supports ABS mode, as long as the servo amplifier is added with another battery, it can constitute an absolute position system.

4. The more powerful servo setting software MR-configurator is more convenient to use and has accurate mechanical analysis function.

Mitsubishi servo motor MR-ES series

1. MR-ES series can be divided into MR-E-A-KH003 (position control mode and speed control mode) and MR-E-AG-KH003 (speed control mode and torque control mode of analog input) from the control mode.

2. The latest encoder of MR-ES series supporting servo motor adopts an incremental position encoder with 131072 pulse/speed resolution.

Mitsubishi servo motor MR-E series

The Mitsubishi GM AC Servo MR-ES series was developed based on the MR-J2S series, and is an AC servo series that maintains high performance but limits its functions.

The MR-ES series can be divided into MR-E-A-KH003 (position control mode and speed control mode) and MR-E-AG-KH003 (speed control mode and torque control mode with analog input) in terms of control mode.

The latest encoders in the MR-ES series with servo motors use incremental position encoders with 131072 pulse/rotation resolution.
More on that
Precautions related to transportation control of lithium batteries - Mitsubishi Precautions related to transportation control of lithium batteries - Mitsubishi

This Skills Brief introduces the United Nations requirements for lithium battery shipment controls and United States guidelines for lithium battery shipment controls. In addition, the content shown in this skill newsletter will be discontinued as of March 2020. ...

Mitsubishi FX3u interrupts the location command Mitsubishi FX3u interrupts the location command

The main effect of aborting the positioning instruction is that in some machine tools, when we give the abort signal and can walk to the distance we set, for example, if the mechanical structure needs to use the sensor to determine the position to go, you can use the abort positioning instruction to do, when the induction gives the abort.

Mitsubishi servo motor jog forward and reverse Mitsubishi servo motor jog forward and reverse

Control requirements: press and hold the forward rotation button, the servo motor rotates forward, release the forward rotation button, and the servo motor aborts the work. Press and hold the rotary button, the servo motor rotates, release the rotary button, and the servo motor aborts the work. When turning forward, pressing the turn button has no effect. When turning, pressing the forward turn button is invalid ...

Introduction to the capacitive role of Mitsubishi inverter Introduction to the capacitive role of Mitsubishi inverter

Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles. ...

Mitsubishi servo motor alarm code and processing skills Mitsubishi servo motor alarm code and processing skills

1. Mitsubishi servo drive alarm code AL31.1 Fault analysis: It is the motor overspeed alarm. Cause analysis: 1. The frequency of a single pulse of the input command is too high; 2. The acceleration and deceleration time is too small, resulting in overshoot and too large; 3. Mitsubishi servo system is unstable; 4. Electricity ...

Mitsubishi tension controller principle Mitsubishi tension controller principle

1. Tension Manipulator Principle - Introduction The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the human ability to ...

Mitsubishi inverter E6 and E7 are faulty Mitsubishi inverter E6 and E7 are faulty

E6, E7 fault for the majority of users must not be unfamiliar, this is a more common Mitsubishi inverter typical problem, of course, the cause of damage is also multifaceted. IC 1302H02 is damaged, which is a piece of integrated drive ...

Mitsubishi touch screen GT10 series models and their features Mitsubishi touch screen GT10 series models and their features

GT1020 touch screen ● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches ●3-color LED backlight for added visibility ●High brightness liquid crystal, clear under light ● Resolution 160×64, standard memory 512K ●Inside ...

Mitsubishi PLC commonly used model features Mitsubishi PLC commonly used model features

FX Series PLC: The FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in standard mode. In the meantime, the FX series 5U is suitable for any industry, and is widely used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...

MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT

With the spread of industrial robots in the production site, more and more on-site issues need to be solved, such as the need for more robot programming engineers, which increases the human cost; The teaching is complicated, which increases a lot of non-production time; Set up guardrails to increase the cost of space and installations; Robot...

How does Mitsubishi PLC work? How does Mitsubishi PLC work?

1. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting. 2. Each scan process. The convergence samples the input signal. The convergence rewrites the output signal. 3. The inner ...

Mitsubishi PLC set and reset command use example Mitsubishi PLC set and reset command use example

1 SET Directive The SET instruction is called an enthronement instruction. Its function is: to drive the coil, so that it has a self-locking function, and insists on the connection condition. In the diagram, when the moving contact X0 is closed, the SET command is executed to turn on the Y0 coil. After X0 is disconnected, the Y0 coil continues to insist on the ON condition, ...

Mitsubishi PLC encryption process Mitsubishi PLC encryption process

The encryption process is as follows: ** Open the serial port for the first time [00000000] IOCTL_SERIAL_SET_BAUD_RATE Baud Rate: 9600 (Set baud rate here) [00000000] IOCTL_SERIAL_SET_LIN ...

Mitsubishi inverter control method Mitsubishi inverter control method

There are several ways to classify Mitsubishi inverters: According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter; Depend on...

Test the output voltage of the inverter – Mitsubishi Test the output voltage of the inverter – Mitsubishi

Because the output voltage of the inverter (Variable-frequency Drive, VFD) is generally 380 volts, there should be no problem in direct measurement, but in practice, most multimeters cannot get a correct reading when testing the output voltage of VFD, and in some cases the multimeter may be burned directly. ...

The GOT widescreen family has been expanded with the GT2512 The GOT widescreen family has been expanded with the GT2512

When industrial automation enters the era of artificial intelligence. Human-computer interaction has long surpassed the simple control of machines, and has been upgraded to obtain more information, use more functions and new skills for more accurate and efficient control, and complete the intelligent manufacturing promotion of industrial automation. ...

Mitsubishi servo motor realizes positioning function Mitsubishi servo motor realizes positioning function

The motion control command of the PLC realizes the perfect positioning function. Briefly describe the Mitsubishi PLC positioning instructions, which can be divided into origin regression instructions DSZR, ZRN, positioning instructions PLSY, PLSR, DRVI, DRVA, variable speed operation PLSV.3 In the meantime, PLSY and PLSR are pulse output instructions, and their positioning functions are relatively ...

Mitsubishi PLC and inverter are communication methods Mitsubishi PLC and inverter are communication methods

The output point and COM point of PLC (MR type or MT type) are directly related to the STF (forward rotation engine) of the inverter. overflow-wrap: break-word !important; ">. RH (high speed), RM (medium speed) important; overflow-wrap: break-word !important; ">、R ...

Mitsubishi FX5U series PLC advantages Mitsubishi FX5U series PLC advantages

1. CPU function As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB. 2. Built-in analog input and output (alarm output by the way) Built-in 12-bit 2-channel analog input ...

Capacitive action in Mitsubishi inverters Capacitive action in Mitsubishi inverters

Introduction to the names and effects of capacitors in different circuits Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383