Siemens APT Relays - Maintenance Methods for Solid State Relays

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. The influence of the ambient temperature

The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be equipped with radiators and fans when the strong cooling device should pay attention to the good contact between the bottom of the relay and the radiator and consider coating an appropriate amount of thermal grease to achieve the best heat dissipation effect.

If the relay temporarily works at a high temperature of 40°C-80°C), the user can consider derating to ensure normal operation according to the maximum output current and ambient temperature curve data provided by the manufacturer.

2. Over-current and over-voltage protection measures

When the relay is used, the internal output of the solid state relay will be permanently damaged due to overcurrent and load short circuit, so the fast fuse and air switch can be considered in the control loop for maintenance; It is also possible to connect the RC absorption loop and varistor at the output end of the relay to achieve output maintenance. The selection principle is 500V-600V varistor for 220V, and 800V-900V varistor for 380V.

3. Relay input loop signal

When the input voltage is too high or the input current is too large to exceed the rated parameters specified, it can be considered to connect the voltage divider resistor in series at the input terminal or connect the shunt resistor at the input port in parallel, so that the input signal does not exceed its rated parameter value.

4. When used specifically, the control signal and load power supply should be stable, and the fluctuation should not be greater than 10%, otherwise voltage stabilization measures should be taken.

5. When the device is used, it should be kept away from electromagnetic interference and radio frequency interference sources to prevent the relay from malfunctioning out of control.

6. When the solid state relay is open and there is voltage at the load end, there will be a certain leakage current at the output end, which should be paid attention to when using or designing.

7. When the solid-state relay fails to be replaced, the original model or the product with the same technical parameters should be selected as far as possible to match the original application line and ensure the reliable operation of the system.
Siemens APT Relays - Maintenance Methods for Solid State Relays

More on that
Siemens APT limit switches – what are the limits used for? Siemens APT limit switches – what are the limits used for?

daily life There are many applications of travel switches, and it is found in many electrical appliances. So what does such a simple switch do? It mainly plays the role of chain protection. The most common example is its use in washing machines and tape recorders (VCRs). ...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

Siemens apt - TL series police lights frequently asked questions Siemens apt - TL series police lights frequently asked questions

1. How many light sources are there for the TL-70 police light? There are 3 types, namely LED, incandescent and xenon. 2. What are the colors of the TL-70 police light? There are 5 types, which are red, yellow, green, blue, and white. 3. What are the types of TL-70 police lights? 3 ...

Siemens APT Relays – Classified by relay form factor Siemens APT Relays – Classified by relay form factor

(1) Miniature relay: the longest side of the relay is not more than 10 mm. (2) Ultra-miniature relay: the longest side size is greater than 10 mm, but not more than 25 mm. (3) Small miniature relay: the longest side size is greater than 25 mm, but not large...

Siemens APT Relays – The action of high and low voltage relays and how to adjust the low voltage side Siemens APT Relays – The action of high and low voltage relays and how to adjust the low voltage side

1. Disconnect the control power supply: Before making the low-voltage terminal contact adjustment, the control power supply should be disconnected first to avoid the current directly or indirectly passing through the relay contact, and avoid electric shock or damage to the relay. 2. Open the relay cover: Open the relay cover, you can see the inside of the relay.

Siemens APT current transformers – measures to reduce errors Siemens APT current transformers – measures to reduce errors

The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error (1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple. (2) Increase the cross-section of the iron core and shorten the magnetic circuit.

Siemens APT limit switch - wiring method of limit switch Siemens APT limit switch - wiring method of limit switch

1. First of all, there is a general understanding of the knowledge of the limit switch, which is usually composed of a shell, an interconnection system and an operating head. 2. First of all, the limit switch should be set to the desired location, and then connected, in addition, it is necessary to figure out the meaning of different letters, such as NC for the long ...

Siemens APT Relays - High Voltage Relay Fault Causes and Solutions Siemens APT Relays - High Voltage Relay Fault Causes and Solutions

1. Some common faults of high-voltage relay coils 1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected. 2 ...

Siemens APT Relays – Classified by relay load Siemens APT Relays – Classified by relay load

(1) Micro-power relay: when the contact open circuit voltage is DC 28V, the (resistivity) is 0.1A, 0.2A relay. (2) Weak power relay: when the contact open circuit voltage is DC 28V, (resistivity) is 0.5A, 1A relay. (3) Medium power relay ...

AD16-30JC Series Combination Light FAQ AD16-30JC Series Combination Light FAQ

1. What are the basic combination colors of combination lights? Red, yellow, green, blue, white, bicolor. 2. What are the different types of combination light panes? F, H, L, V, G any combination 3. Is the lampshade detachable? OK 4. Combination light ...

Siemens APT Relays - What are the relays that burn out? Siemens APT Relays - What are the relays that burn out?

1. The position of the auxiliary contact is not suitable. After the switch has been tripped, the mechanical part has moved, worn phenomenon, resulting in the auxiliary contact position offset to the correct position, in the protection action tripping, when the auxiliary contact is not disconnected, the outlet electrical appliances, electrical appliances, relays have returned, and it is ...

Siemens APT Relays – Components of Solid State Relays Siemens APT Relays – Components of Solid State Relays

Solid state relays consist of three parts: the input circuit, the isolation (coupling), and the output circuit. Input circuitry According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, AC input circuit and AC and DC input circuit. Some input control circuits are also ...

Siemens APT – PB1 Series FAQs Siemens APT – PB1 Series FAQs

1. What are the installation methods of PB1 button? PB1S and PB1L are fastened with metal screws, and PB1J and PL1 are fastened with plastic nuts. 2. PB1 series pushbuttons can be assembled with up to several sets of contact modules as standard 2*3=6 3. PB1S shell ...

Siemens APT Relays - a detailed introduction to the classification of relays Siemens APT Relays - a detailed introduction to the classification of relays

Classified according to the working principle or structural characteristics of relays: 1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature. 2) Solid state relay: refers to the electronic components that perform their functions without mechanical ...

Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays

merit 1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.

Siemens APT Relays – Analysis of Common Faults and Causes of Relays Siemens APT Relays – Analysis of Common Faults and Causes of Relays

1. Overhaul of the sensing mechanism For electromagnetic (voltage, current, intermediate) relays, the sensing mechanism is the electromagnetic system. The faults of the electromagnetic system are mainly concentrated in the coil and the moving and static iron cores. (1) Coil fault maintenance Coil failure usually has a coil absolute...

Siemens APT transformer - the use, principle and selection of current transformer Siemens APT transformer - the use, principle and selection of current transformer

The principle of the current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. Its primary side winding turns are very small, string in the line of the current that needs to be measured, so it often has all the current of the line flowing through, the number of turns of the secondary side winding is relatively large, and the series ...

Siemens APT relay - common faults and solutions for high-voltage relays Siemens APT relay - common faults and solutions for high-voltage relays

1. Poor contact Poor contact is one of the most common faults in high-voltage relays, which can lead to problems such as hot terminals ® and burned contacts. Workarounds include regularly checking terminals and set screws for loose and cleaning contact surfaces. 2. Excessive wear At...

Siemens APT Relays – The difference between AC relays and DC relays Siemens APT Relays – The difference between AC relays and DC relays

1. Structural characteristics of AC relays The coil of the AC relay is shorter, and the wire diameter is thicker, mainly because the coil is passed through the alternating current, the reactance is larger, and the thick wire diameter can reduce the internal resistance and reduce the heat generation.

TL series police lights frequently asked questions TL series police lights frequently asked questions

1. How many light sources are there for the TL-70 police light? There are 3 types, namely LED, incandescent and xenon. 2. What are the colors of the TL-70 police light? There are 5 types, which are red, yellow, green, blue, and white. 3. What are the types of TL-70 police lights? 3 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top