Schneider Vijeo-Designer compilation error factor

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Q1833: Because you are using an older version of Runtime, the download does not last. Please use the Runtime Device program on the Vijeo Designer CD to upgrade the runtime.

This error message appears when you download to an iPC/PC that is running an older version of the runtime.

Solution:

Use the Runtime Setup program on the Vijeo Designer CD to install the runtime.

Issue 2000: [Part Designation, DLL Designation, File Number, or Line Number] Internal fault.

Unknown fault.

Solution:

Save the project and restart Vijeo-Designer.

If the above actions do not eliminate the fault, pay attention to the error message and back up your project. Then, flip through the previously backed up project.

If the error message still appears, please uninstall and re-install the software, and then add a backup project to it.

If the issue persists, please contact Customer Support.

                                 Schneider Vijeo-Designer compilation error factor

Question 2001: [Policy Type] [Policy Name] [Characteristic Name] requires a string.

The specified feature is empty.

Solution:

Type a string.

Issue 2002: [Policy Type] [Policy Name] [Characteristic Name] requires a numeric value.

The specified feature is empty.

Solution:

Type a numeric value.

Issue 2003: [Policy Type] [Policy Name] [Designation] does not adhere to the naming protocol.

The title you define includes an invalid character or the title is a reserved word.

Solution:

Invalid Characters: Please reinclude the title of the character useful. For more information on useful characters, please refer to the Vijeo-Designer Help documentation.

Reserved words: Java keywords and Vijeo Designer keywords cannot be used as titles. For a list of all Vijeo-Designer reserved words, please refer to the Vijeo-Designer Help documentation.

Issue 2005: [Policy Type] [Policy Name] [File Name] Invalid file name.

The file name uses an invalid naming format.

Solution:

The length of the file name must be 5 characters or less (with an additional 3-character file extension)

The file may not exist

Issue 2006: The [policy type] [policy name] [file name] file does not exist.

The specified file could not be found.

Solution:

Make sure that the file exists, and that the file path and file extension you type are correct. The file may have been moved.

Issue 2007: Ways in which [policy type] [policy name] [document name] are invalid.

The file route uses invalid characters.

Solution:

Refer to your operating system's manual for information on how to define file paths.

Issue 2008: [Policy Type] [Policy Designation] [File Name] The route does not exist.

Issue 2008: [Policy Type] [Policy Designation] [Domain Name] The path to the optional drive is not defined. Please specify a pathway.

No file path found.

Solution:

Confirm that you have entered the correct document route. The directory may be moved or deleted.

Issue 2009: The text of [policy type] [policy name] [feature name] is too long. The longest is [integer].

Too many characters are used in the specified features.

Solution:

Reduce the number of characters so that its length is less than the number of characters specified in the fault message.

Question 2018: [Policy Type] [Policy Name] [Characteristic Designation] It is necessary to be less than or equal to [integer].

The specified value is greater than the maximum allowed.

Solution:

Enter a value less than or equal to the value given in the fault message.

Question 2020: [Policy Type] [Policy Name] [Feature Name] requires a numeric value.

The specified feature includes an invalid value.

Solution:

Type a useful number.

Question 2021: [Policy Type] [Policy Name] [Feature Name] needs to be an integer.

The specified value is invalid.

Solution:

Type an integer value.

Question 2023: [Policy Type] [Policy Name] [Feature Name 1 or Feature Name 2] is out of scope. The useful range is from [integer 1] to [integer 2]. [Characteristic Name 1] plus [Characteristic Name 2] should be less than [Integer 3].

The values are beyond the useful range. The sum of the specified characteristics cannot exceed [integer 3].

Solution:

Enter a specified range of values: [integer 1] to [integer 2].

Question 2025: [Policy Type] [Policy Name] [Feature Name 1] is not equal to [Feature Name 2].

These two specified values are considered to be equal.

Solution:

The [Feature Name 1] typed is not the same as [Feature Name 2]. It is necessary that the difference in the characteristic values be greater than 0.001.

Issue 2027: [Policy Type] [Policy Name] [Feature Name] requires one character.

The specified feature is empty.

Solution:

Enter a character.

Question 2028: [Policy Type] [Policy Name] [Feature Name 1] It is necessary to be greater than [Feature Name 2].

The value of feature name 1 is less than the value of feature name 2.

Solution:

Please enter a value so that [Feature Name 1] is greater than [Feature Name 2].

Issue 2030: [Policy Type] [Policy Name] [Title] [Entered Title] is invalid. The title is already in use.

Another policy within the same policy is using the designation designation.

Solution:

Type a unique title.

Issue 2031: [Policy Type] [Policy Name] [Feature Name] [Feature Content] is invalid. Values are already in use.

In the same policy, another policy of the same type is applying the specified value.

Solution:

Type a unique value.

Question 2032: [Policy Type] [Policy Name] [Title] Invalid title.  [Type title] is a reserved keyword.

Java and Vijeo-Designer keywords cannot be used as policy designations.

Solution:

For a list of all reserved keywords, see the Vijeo-Designer Help documentation.

Issue 2035: [Policy Type] [Policy Name] [Line Type] cannot be set to [No-See] because [Color Animation] is enabled.

The line type cannot be set to [No, See], as this will invalidate the guideline's color animation.

Solution:

Removed the color animation so that the line type could be set to "No".

Issue 2036: [Policy Type] [Policy Name] [Drawing] is not possible because [Animation Type] is enabled.

This is because if the drawing is set to "No See", the color animation and fill animation of the policy will be invalidated.

Solution:

Remove the color or fill animation, then you can set the picture to "no".

Issue 2037: [Policy Type] [Policy Name] [Bitmap Display] cannot be "true" because [Animation Type] is enabled.

When a bitmap appears "true", the text policy is converted to a bitmap and used as an image policy. The image guidelines do not support color or numerical animation.

Solution:

Remove color or numeric animations to set bitmap rendering to true.

More on that
There is a remote code execution vulnerability in Schneider industrial equipment There is a remote code execution vulnerability in Schneider industrial equipment

Recently, Armis security researchers have reported that Schneider Electric's programmable logic manipulators (PLCs) have serious and unpatched gaps in long-distance code fulfillment, allowing intruders to manipulate their various industrial systems. Schneider ...

Schneider Modicon M100 Programmable Controller Features and Benefits Schneider Modicon M100 Programmable Controller Features and Benefits

The Schneider Electric Modicon M100 programmable controller is part of the Easy Series and is suitable for simple I/O logic control machines. characteristic AC power supply High-speed processor with 0.2μs/boolean amount Built-in a ...

Inverter maintenance inspection steps – Schneider Inverter maintenance inspection steps – Schneider

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation conditions, and do the corresponding recording operations; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

Schneider inverter and PLC connection problems Schneider inverter and PLC connection problems

When the inverter is used to form an automatic control system for control, in many cases, PLC and inverter are used together, and how to correctly connect the PLC and inverter together has become the key to the success of the system. 1.PLC switch ...

U-tube manometer error analysis – Schneider U-tube manometer error analysis – Schneider

(1) Temperature error. This refers to the change of the length of the scale and the density of the working fluid due to the change of ambient temperature, and the former can be ignored in general, and the latter should be appropriately corrected. For example, when water is changed from 10°C to 20°C, its density changes from 999. 8kg/m^3 reduced to 999.8kg/m^3 ...

Schneider ATV610 inverter applications Schneider ATV610 inverter applications

The Schneider ATV610 inverter is suitable for specification loads and can be used in a wide range of industries and infrastructure. Including: petrochemical, power plant, industrial and civil buildings, water treatment and sewage treatment, HVAC, thermal heating, constant pressure water supply, and other applicable occasions. In these jobs ...

Is there a restriction on the installation direction when Schneider installs the inverter? Is there a restriction on the installation direction when Schneider installs the inverter?

It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large, takes up a lot of space, and the cost is relatively high. This can be done by: (1) The planning of the disc should be based on the heat dissipation required by the actual device; (2) Profit ...

Features of Schneider's different PLC series Features of Schneider's different PLC series

Schneider PLC series mainly includes: Schneider NEZA PLC (Schneider TSX08 series); Schneider Quantum PLC (Schneider 140 series); Schneider Micro PLC (Schneider TSX37 series); Schneider Premium PLC (Schneider TSX...

Dynamic phase angle tuning of inverter motors – Schneider Dynamic phase angle tuning of inverter motors – Schneider

1. The control cabinet, the main engine, and the brake connection line are correct, and the voltage is correct; 2. Safety circuit, door lock circuit is normal, limit switch, speed change switch and close; 3. The connection cable from the encoder to the PG card must be reliable and accurate; ...

The cause of leakage in the motor using the inverter - Schneider The cause of leakage in the motor using the inverter - Schneider

1. The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so high-frequency leakage current will occur. The PE points of the three transmission equipment of the inverter, the pre-power supply transformer and the motor must be connected together and then grounded consistently. Frequency conversion...

The control mode of low-voltage inverter - Schneider The control mode of low-voltage inverter - Schneider

From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods: 1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...

Schneider medium-voltage inverters focus on energy saving Schneider medium-voltage inverters focus on energy saving

Because the impact of foreign electrical products on domestic electrical equipment is relatively large, now Schneider inverter equipment occupation is facing a big technical promotion, taking inverter as an example, the national connotation of inverter shopping mall domestic brand and foreign brand, regardless of technology, processing and manufacturing, industrial design and other aspects are still ...

"Five Ways" to Solve Life Sciences Industry Challenges – Schneider "Five Ways" to Solve Life Sciences Industry Challenges – Schneider

In life sciences careers, equipment performance is critical to ensuring business continuity and useful production time. The main challenges faced by the industry include: maintaining the positive impact of environmental parameters on product quality, managing multiple systems in a "siloed" state, and using existing infrastructure sensitively and efficiently.

Schneider AC inverter usage category Schneider AC inverter usage category

Under the IEC60947-4 standard, the Schneider communication contactor TVR series must be able to turn on and break the current value, and these currents depend on the type of break that the load is turned on, including squirrel cage or slip ring motor, resistor, when the switch or break is generated in the motor abort, start or run...

Precautions for Schneider motors when operating above 60Hz Precautions for Schneider motors when operating above 60Hz

When operating beyond 60Hz, the following precautions should be taken (1) 1 Machinery and devices should be able to operate at this speed (mechanical strength, noise, oscillation, etc.). (2) The motor enters the constant power output range, and its output ...

Turbine flowmeter selection factor - Schneider Turbine flowmeter selection factor - Schneider

Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high quality ...

The difference between vector inverter and general-purpose inverter - Schneider The difference between vector inverter and general-purpose inverter - Schneider

There are two main differences between vector inverters and general-purpose inverters. One is high control accuracy, and the other is high output torque at low speed. Vector special inverter: The operating principle of the vector special inverter is to carry out inverter after rectification, ...

Power wiring requirements for Schneider PLC Power wiring requirements for Schneider PLC

The power supply of the DPLC should be taken from the trunk line with a relatively stable voltage or the special line led by the bus of the substation to ensure the voltage quality of the PLC. If the voltage fluctuates too much, consider installing a voltage regulator or uninterruptible power supply (UPS). 2. The power cord is best to use twisted pair, and its cross-sectional area should not be less than 2 square millimeters.

Schneider PLC failure steps Schneider PLC failure steps

(1) If the signal is controlled on a counter, first look at the logic that controls the reset, then the counter signal. Follow steps 2 to 5 above. (2) If Schneider PLC aborts in some places where the output is encouraged, generally in the middle of the situation, then look for the next step ...

Automatic control instrument construction content and procedures - Schneider Automatic control instrument construction content and procedures - Schneider

1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed planning documents), construction organization planning, equipment list, data budget, and list of machined parts; 2. Cooperate with civil engineering majors to do a good job of embedding, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top