In the PLC control system, the content that needs to be displayed mainly has timer value, counter value and data register value, and the data display method can be summarized into two fundamental types: one is based on the PLC data communication interface, such as RS-232, RS-485/422, and the display device also has such an interface, and the data display is completed through the data communication method.
According to the data display skills of communication, the data communication interface is used to transmit and display data, which is an effective way to complete the PLC data display. Mainstream PLCs now provide standard RS-232 or RS-485/422 interfaces, perhaps with module extensions to add such interfaces.
The communication modules 232ADP, 232BD, 485BD and 485ADP of the Mitsubishi FX2N can be used as data interfaces. The display device can choose a special intelligent display screen and a general computer (PC), and directly select the display screen or touch screen matched with the PLC, which can complete the centralized display of multiple data inside the PLC, and can use editing software to edit the screen graphics to improve the visibility of the display interface. The FX series can be matched with F93000T-BWD, F940GOT-LWD and F940GOT-SWD. The intelligent display screen reads the registers of the PL through the communication interface, and the data displays the power, which can simplify the planning of the control system. However, due to the cost of the display, the application of large-size display screen is limited, so this method is suitable for compact PLC control system. With the further improvement of computer performance and reliability, the control system in the form of "PC+PLC" has been widely used in the field of industrial control, PC with abundant software and hardware resources, can complete the online monitoring of PLC, concentrate on a lot of PLC internal data, can show the dynamic process flow and data trend curve of the control equipment in a graphical way, so that the human-machine interface of the system is intuitive and friendly.
PLC and the communication connection of the group Taiwang
1:1 station, spaced 15 meters apart, driven by a programming port
Communication through programming port (PLC does not need to be programmed)
1:N multiple stations (16 more stations), 50 meters > 15 meters apart> with FX485 drive
1:N multiple stations (16 more stations), 500 meters > > 50 meters apart, driven by FX485
1:N multiple stations (16 more stations), 1200 meters> > 500 meters apart, driven by FX485 (plus 485 relay)
RS485 can be wired in one or two pairs of wires. According to the use of the method to decide the connection, this plan is selected two pairs of wire connection method.
In order to establish the communication connection between PLC and Group Taiwang, the communication address and communication parameters can be set in the menu "PLC/serial port setting" of the PLC programming software, and the programming (MOV instruction) can also be completed directly in the software, according to RS485, the specific settings are:
The baud rate is set to 9600 bit/s, the data bit is set to 7 bits, the L bit is set to the start bit, the 2 bits are aborted, and the even check is selected, and protocol 1 is selected. Set with programming software, where the correspondence address is set in the D8121.
The accuracy of the timer is related to the arrangement of the program, and if the contacts of the timer are in front of the coil, the accuracy will be reduced. The average error is about 1.5 times the scan cycle. The small timing error is the input filter time minus the resolution of the timer, which is 1ms, 10ms, and 100ms for 1ms, 10ms, and 100ms, respectively.
If the timer contacts are behind the coil, the large timing error is 2 times the scan cycle plus the input filter time. If the contact of the timer is before the coil, the large timing error is 3 times the scan cycle plus the input filter time.
|
More on that
|
Maintenance method of Mitsubishi inverter
Electrical characteristics view
Mitsubishi inverters that have been running and placed for a long time, due to the influence of the environment and the aging of inverter equipment, it is necessary to check and maintain the electrical performance of Mitsubishi inverters regularly. A comprehensive review of the input, rectifier and inverter, DC input fuses found ...
|
|
Introduction to the principle of Mitsubishi tension controller
The tension controller can be called the tension manipulator, which is generally equipped with magnetic powder brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the ability to give a certain amount of output through the tension manipulator ...
|
|
PLC circuit debugging precautions - Mitsubishi
1. For the switching input and output circuits, pay attention to the consistency criterion of maintaining the state; The positive logic criterion is usually used, that is, when the input and output are live, it is in the "ON" state and the data value is "1"; Conversely, when the input and output are powered off, it is in the "OFF" state and the data value is "0". Such...
|
|
How Mitsubishi PLC works
A. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting.
B. Each scanning process. The convergence samples the input signal. The convergence rewrites the output signal.
C. Component image register ...
|
|
How to deal with Mitsubishi PLC failures - Mitsubishi
01. Base system problem
In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base.
2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...
|
|
Mitsubishi PLC login password setting operation
Method 1
1. Hit the PLC from RUN to STOP
Mitsubishi's PLC has a special method of setting landing keywords, and it is necessary to ensure that the PLC is in a state of shutdown in order to successfully write the landing keywords.
In the run running condition, the performance of the write will appear "Unable to ...
|
|
Mitsubishi FX1N switching power supply fault repair
Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged).
Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.
|
|
Mitsubishi drive functions and functions
1. Control the start, stop, speed and so on of the servo motor;
2. Carry out various maintenance on the motor (overload, short circuit, undervoltage, etc.)
3. React to external signals and control servo motors (position, speed, torque) through internal PID conditioning;
...
|
|
Test the output voltage of the inverter – Mitsubishi
Because the output voltage of the inverter (Variable-frequency Drive, VFD) is generally 380 volts, there should be no problem in direct measurement, but in practice, most multimeters cannot get a correct reading when testing the output voltage of VFD, and in some cases the multimeter may be burned directly.
...
|
|
Mitsubishi inverter overload fault judgment method
1. Check whether the three-phase electricity of the motor is balanced
(1) If the three-phase voltage of the motor is unbalanced, then check whether the three-phase voltage at the output end of the Mitsubishi inverter is balanced.
(2) If the three-phase voltage of the Mitsubishi inverter is also unbalanced, the problem is inside the Mitsubishi inverter, and it should be investigated.
|
|
PLC controller and human-machine interface anti-interference countermeasures - Mitsubishi
When carrying out anti-disturbance planning for specific projects, it is necessary to select products with high anti-disturbance ability, and adopt methods such as pressing the disturbance source, cutting off or attenuating the propagation path of electromagnetic disturbance, and using software means to improve the anti-disturbance ability of equipment and systems.
...
|
|
How to write a holding circuit for Mitsubishi PLC
There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed once through the insistence circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit.
...
|
|
Programming element for Mitsubishi FX2N series PLCs
Each element of the Mitsubishi FX2N series PLC is indicated by a characteristic letter, such as X indicates the input relay, Y indicates the output relay, M indicates the auxiliary relay, T indicates the timer, C indicates the condition element, etc., and these elements have a specified number.
...
|
|
Mitsubishi PLC control servo motor method
1. The transistor output type of the FX series generally sends pulses to the servo through the output point of Y0, Y1 or the positioning module, and the speed and direction of the servo depend on the frequency and direction of the pulse in your program.
Mitsubishi FX3U series ...
|
|
Mitsubishi Q series PLC and GX Works2 connection method
01 USB connection
USB connection requires the device USB driver, generally the device will be actively driven after the installation of GX Works2 software, but at a single time due to anti-virus software or system reasons, or the device may not be available, then we need to manually drive the device to the accounting machine. The specific device method is ...
|
|
Mitsubishi PLC selection 5 elements
Mitsubishi PLC selection - element 1: IO points
The number of ZUI IOs that can be accessed by the Mitsubishi PLC control system.
Mitsubishi PLC FX series now commonly used basic unit host is: FX1SFX1N, FX1NC, FX2N, FX2NC, FX3U. FX3UCFX3G, FX5U, 9 series.
...
|
|
Mitsubishi inverter basic questions and answers
1. Question: What is the type of RS485 to RS232C converter used by Mitsubishi inverter for communication?
Solution: FA-T-RS40* Mitsubishi inverter is available.
2. Question: Mitsubishi inverter frequency external potentiometer is given, and the external potential recommended to be used ...
|
|
Mitsubishi Electric develops production line improvement technology
TOKYO, March 26, 2020 – Mitsubishi Electric Corporation (TSE: 6503) announced today that it has developed a new technology for efficient design and material flow of production floor layouts and accurate estimates ® of productivity using Mitsubishi Electric's Maisart *AI.
|
|
Mitsubishi PLCFX3U positioning control
Origin regression command with DOG lookup function
Mitsubishi PLCFX3U origin regression command with DOG lookup function: DSZR.
1. The workbench runs in the direction of the value reduction of the current value register (generally runs in the opposite direction M8342 ...
|
|
Characteristics of servos and advantages of Mitsubishi servos
The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system.
|
|