The servo system is an automatic control system that enables the output of the object's orientation, direction, and state to change with the arbitrary change of the input quantity (or given value). In the automatic control system, the system that can echo the control signal with a certain degree of accuracy is called the follow-up system, also known as the servo system. The main task of the servo is to expand, convert and control the power according to the requirements of the control command, so that the torque, speed and azimuth output of the driving equipment can be controlled very flexibly and conveniently.
The servo system is generally composed of three parts: a controller, a servo amplifier, and a servo motor. After the start of work, the power supply is transmitted to the servo motor through the servo amplifier, and the motor starts to work, and the encoder located at the tail of the servo motor at this moment feeds back the motor orientation information that collects to the servo amplifier, and the amplifier transmits to the controller, and the controller makes a judgment and announces the instruction information after getting this information, and controls the work and orientation of the servo motor.
The advantages of Mitsubishi servo system are as follows:
1. The servo motor stops in the regular direction according to the command announced by the control equipment, but due to inertia, the motor cannot be stopped instantaneously after the command is announced, there is a delay in time, and the machine will vibrate when the motor is working. In response to this delay and vibration, Mitsubishi Electric has developed advanced control skills, and the servo system is agile to stop and activate in a short period of time after the control equipment announces the command.
2. The control accuracy of Mitsubishi Electric's servo system is high, and the accuracy of the encoder can reach one millionth of a turn, which is at the leading level in the world.
3. At present, there are many manufacturers of servo motors in the world, but there are not many manufacturers who can supply controllers, servo amplifiers, inverters and other series of equipment at the same time.
|
More on that
|
Introduction to the selection conditions of Mitsubishi A840 series inverters
Q: When will I choose the A840 series inverter?
A: A800 series inverters are generally used in heavy-duty occupations, such as lifting occupations, mixer occupations will use A800 series. At the same time, it is a vector inverter, so customers need to do closed-loop speed control, torque control may ...
|
|
Anti-interference measures for PLCs and touch screens - Mitsubishi PLC
1. Select the power supply with excellent performance and press the disturbance introduced by the power grid
The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Isolation transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in isolation...
|
|
Mitsubishi PLC programming cable communication port setting method
1. Plug the programming cable into the USB port of the computer.
2. On the desktop, place the mouse on the "My Computer" icon, and then right-click.
3. In the pop-up menu, select "Device Manager".
...
|
|
The cause of the failure caused by OC - Mitsubishi inverter
1. Aging of drive circuit
Due to the long-term use, it will inevitably lead to the aging of components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm often appears as soon as it is running.
...
|
|
Mitsubishi servo problems and how to troubleshoot them
1、AL. E6 - indicates servo emergency abort. There are generally two reasons for this shortcoming, one is that the 24V power supply of the control circuit is not connected, and the other is that there is no connection between the EMG and SG of the CN1 port.
2. AL.37 - parameter abnormality. The internal parameters are chaotic, and the operator may set the parameters by mistake or drive ...
|
|
MITSUBISHI MELFA ASSISTA COLLABORATIVE ROBOT
With the spread of industrial robots in the production site, more and more on-site issues need to be solved, such as the need for more robot programming engineers, which increases the human cost; The teaching is complicated, which increases a lot of non-production time; Set up guardrails to increase the cost of space and installations; Robot...
|
|
Precautions for the use of Mitsubishi servo motor with brake
1. Occasions to choose a servo motor with brakes:
The servo motor is mainly loaded through the motor shaft, if the load driven by the motor shaft is in the straight direction, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the effect of gravity, so that ...
|
|
Mitsubishi inverter pre-use debugging steps
1. No-load energizing test of Mitsubishi inverter.
1. Ground the ground terminal of the Mitsubishi inverter.
2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch.
3 Check whether the factory display window of Mitsubishi inverter is normal, if it is not correct.
|
|
Capacitive action in Mitsubishi inverters
Introduction to the names and effects of capacitors in different circuits
Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...
|
|
Software or hardware reasons for Mitsubishi PLC crash
1. Hardware
(1) I/O channeling, the PLC automatically detects the I/O fault and enters the STOP mode.
(2) The I/O is damaged, and the program runs to the response signal that needs the I/O, and cannot execute the instruction downward.
(3) Expansion module (functional, such as A/D) ...
|
|
PLC control system daily maintenance process - Mitsubishi
After overhauling and confirming that all connections of the system are accurate, power on the relevant modules until the card indicator is normal.
The initiation process of the system after the scheduled repair is as follows:
(1) Power supply. Open power supply equipment (including throwing up...
|
|
Mitsubishi inverter control method
There are several ways to classify Mitsubishi inverters:
According to the classification of the main circuit operation method, it can be divided into voltage-type inverter and current-type inverter; According to the classification of switching methods, it can be divided into PAM control inverter, PWM control inverter and high carrier frequency PWM control inverter;
Depend on...
|
|
Special function module of the Mitsubishi PLC FX series
The communication module of PLC is used to complete the communication with other PLCs, other intelligent control equipment or computers. The following is a brief introduction to the FX series communication function shields, adapters and communication modules.
(1) Communication expansion ...
|
|
Mitsubishi inverter FR-E700 series is selected
Q: When will I choose the E740 series inverter?
A: E700 is an economical and small inverter with high driving performance, with the function of holding the brake, and can also add options to expand the function, which can be used for transportation, lifting occupations, and has high cost performance.
Q: Mitsubishi inverter E740 should ...
|
|
Test the output voltage of the inverter – Mitsubishi
Because the output voltage of the inverter (Variable-frequency Drive, VFD) is generally 380 volts, there should be no problem in direct measurement, but in practice, most multimeters cannot get a correct reading when testing the output voltage of VFD, and in some cases the multimeter may be burned directly.
...
|
|
Mitsubishi AnS series analog module bias and gain applications
In today's industrial field, when using analog-to-digital conversion or digital-to-analog conversion, most of them do not only use the standard input characteristics of -10V-+10V, 0-20mA, but according to the practical voltage and current values to do the process requirements, then it is necessary to do the AD or DA module ...
|
|
The origin of Mitsubishi servo motion control is returned
1. The so-called positioning is to let the servo motor go to a confirmed position.
2. This direction can be so incremental, or so ***. For example, we are now on the road, and we have to go forward 10 meters, which is equivalent to adding 10 meters to our bearing.
|
|
The interaction between the PLC and the touch screen is consistent - Mitsubishi
When the contact screen is connected with the PLC, in fact, the memory of the PLC is used, (the contact screen also has a small amount of memory, which is only used to store system data, that is, the screen, controls, etc.), the contact screen and the PLC communication is generally a master/slave relationship, that is, the contact screen reads data from the PLC, and after making a judgment, it is displayed in the display ...
|
|
The difference between a Mitsubishi servo motor and a stepper motor
First, the control accuracy is different
The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors that have a smaller step angle after being subdivided. Communicate the control of servo motor ...
|
|
Low-voltage electrical faults and maintenance methods - Mitsubishi
In the process of operation, low-voltage electrical appliances will present problems due to improper use or long-term operation of aging components, and there are many kinds of problems, and the common problems are analyzed and dealt with.
1. Contact problems and repairs
The contact is the primary component of the low-voltage switching coupon, ...
|
|