Mitsubishi FX series PLC error command and solution
1. Error message: NO ERROR--No abnormal error occurs
Abnormal content and cause: No abnormal occurrence
Solution: Check whether the cable connection between the host and the I/O expansion base/module is normal
2. Error message: ...
|
|
Mitsubishi servo drive system requirements
Servo drive system requirements
1. Wide speed regulation
2. High positioning accuracy
3. Satisfactory transmission rigidity and high speed stability
4. Fast response, no overshoot
In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...
|
|
Mitsubishi servo motor is now commonly used
1. Torque control: Torque control is based on external simulation imitation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. Assuming that the load on the motor shaft is less than 2.5Nm, then ...
|
|
The basic logic instructions of the Mitsubishi FX series plc
Fetch Command and Output Command (LD/LDI/LDP/LDF/OUT)
(1) LD (take instruction) - the instruction that the normally open contact is connected with the left bus, and each - logic line that starts with the normally open contact is used with this instruction;
(2) LDI ...
|
|
Mitsubishi PLC module model
FX3S-10MR/ES AC power supply · DC input type input: 6 points DC24V drain/source type output: 4 points relay
FX3S-10MT/ES AC power supply · DC input input: 6 points DC24V drain/source output: 4 points transistor drain type
FX3S-10MT/E ...
|
|
Mitsubishi's introduction to the three-circuit system
Servo motors are generally operated by three circuits. To put it bluntly, the three circuits are three closed-loop control negative feedback PID control systems.
The first innermost PID loop is the current loop, which is implemented completely inside the servo controller. Exercise...
|
|
Mitsubishi inverter E6 and E7 are faulty
E6, E7 fault for the majority of users must not be unfamiliar, this is a more common Mitsubishi inverter typical problem, of course, the cause of damage is also multifaceted.
IC 1302H02 is damaged, which is a piece of integrated drive ...
|
|
Mitsubishi touch screen GT10 series models and their features
GT1020 touch screen
● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches
●3-color LED backlight for added visibility
●High brightness liquid crystal, clear under light
● Resolution 160×64, standard memory 512K
●Inside ...
|
|
A brief description of Mitsubishi's PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. Whereas...
|
|
Mitsubishi FX5U series PLC ten advantages
1. CPU function
As a MELSEC IO-F series PLC actuator, it is equipped with executable structured programs and multiple program actuators, and can be written to ST language and FB.
2. Built-in analog input and output (alarm output by the way)
Built-in 12-bit 2-channel analog input ...
|
|
The solution to the influence of Mitsubishi inverter on the motor
Generally, asynchronous motors are planned according to constant frequency and constant voltage, and it is impossible to completely adapt to the requirements of frequency conversion speed regulation. The following is the influence of the inverter on the motor:
Regardless of the form of the inverter, the building automation training device operates ...
|
|
Find PLC fault method – Mitsubishi PLC
PLC is an industrial small computer, it has a problem, the first thing to clean up is the PLC ontology problem is still a peripheral problem, if there is a problem with the PLC ontology, often the ERR light is on, maybe the red light is flashing, the normal situation is generally RUN running green light, if it is the ontology to produce this kind of problem, ...
|
|
Advantages and disadvantages of Mitsubishi's different output types
The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types?
(1) Transistor output:
The biggest advantage is that it is adapted to high-frequency action, and the echo moment is short, generally about 0.2ms, but it ...
|
|
Mitsubishi PLC Step Instruction Instructions for use
1. Step Instruction (STL/RET) Step instruction is an instruction that is specially planned for sequential control. In the field of industrial control, many control processes can be completed by sequential control, and the use of step instructions to complete sequential control is not only convenient to complete, but also easy to read and modify.
There are two in the FX2N ...
|
|
Mitsubishi low-power Z024 series inverter failure OC cause
(1) Aging of the drive circuit
Due to the use of a long period of time, it will inevitably lead to the aging of components, which will cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm will often appear as soon as it is running.
( ...
|
|
PLC troubleshooting method - Mitsubishi
1. If the PLC stops in the middle of some outputs where the output is excited, then look for the signal that caused the next operation (input, timer, line, drum manipulator, etc.). The programmer will show the ON/OFF status of that signal.
...
|
|
Introduction to Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection greatly reduces the number of wirings and improves the maintainability of the system. Whereas...
|
|
How to adjust the jitter phenomenon of Mitsubishi servo motor
(1) Prerequisites
Mitsubishi servo motors are able to improve the inertia of the motor by adjusting the gain, so as to adapt to the load, but the Mitsubishi servo motor is able to improve endlessly. Under normal circumstances, it is considered that it can withstand within 10-15 times of the additional inertia of the motor, and Mitsubishi reducer is required to be added in addition. We know ...
|
|
Mitsubishi inverter OC causes the failure
1. The ERR problem is an under-voltage problem, which is usually caused by the problem of voltage detection loop resistance or wiring, rather than the actual input voltage showing undervoltage. Most of the OC problems of the A200 series are caused by the damage of the drive circuit, and its drive circuit ...
|
|
The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules
The new iQ-F motion module is a controller that can perform advanced motion control such as positioning, synchronization, cam, speed, torque, etc., with a computing cycle of 500μs, and can be connected to a high-function servo amplifier through CC-Link IE TSN, making a higher contribution to the miniaturization and high functionality of the equipment.
...
|