Maintenance method of Mitsubishi inverter

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

Electrical characteristics view

Mitsubishi inverters that have been running and placed for a long time, due to the influence of the environment and the aging of inverter equipment, it is necessary to check and maintain the electrical performance of Mitsubishi inverters regularly. Conduct a comprehensive inspection of the input, rectifier, inverter and DC input fuses, and replace them in time if they are found to be incinerate; Carefully check whether the terminal strip is aging and loose, whether there is a hidden fault of short circuit, whether the connection of each connecting wire is firm, whether the wire skin is damaged, whether the plug of each circuit board is firm, whether the connection between the main power supply is reliable, whether there is heating and oxidation at the connection, and whether the grounding is good.

Capacitor detection

The main circuit is mainly composed of three-phase or single-phase rectifier bridge, slippery capacitor, filter capacitor, IPM inverter bridge, current limiting resistor, contactor and other components. Among them, the life of Mitsubishi inverter has an impact on the slippery aluminum electrolytic capacitor, and its life is mainly determined by the DC voltage and internal temperature added to its two ends. The type of capacitor is selected according to the supply voltage during the design of the main circuit, so the internal temperature determines the life of the electrolytic capacitor. Check whether the capacitor is leaking, the shell is expanded, bubbling or deformed, whether the safety valve is cracked, and the capacitor capacity, leakage current, withstand voltage, etc. can be tested if conditions permit, and the capacitor that does not meet the requirements can be replaced. The service life of the filter capacitor is generally 5 years, and if the use time is more than 5 years, and its objectives significantly violate the detection standards, it should be replaced as appropriate.

                               Maintenance method of Mitsubishi inverter

It is advisable to check it once every six months

In addition to daily inspection, in many viewing projects, the focus is on the slippery capacitors of the main circuit, the logic control circuit, the power supply circuit, the electrolytic capacitors in the inverter drive protection circuit, and the electric fans in the cooling system. It is difficult to measure capacitors other than those used in the main circuit, so the change in appearance and the time of operation are the first criteria for judgment. In addition, it is necessary to dust and anti-corrosion treatment of Mitsubishi inverters.

Precautions for regular maintenance

Regularly remove dust to check whether the air inlet of the fan is blocked, and clean the air filter cooling air duct and internal dust every month.

Check it regularly, it should be carried out once a year: check whether the screws, bolts and plug-ins are loose, and whether there is a short circuit in the resistance of the input and output reactors to the ground and between phases, which should be greater than tens of megaohms normally. Whether the conductor and insulator are corrosive, if so, should be scrubbed with alcohol in time. Measure the stability of the output voltage of each circuit of the switching power supply, such as: 5V, 12V, 15V, 24V and other voltages. Whether there are traces of ignition in the contacts of the contactor, and the new contactor of the same type or greater than the original capacity should be replaced severely; Acknowledging the correctness of the control voltage and conducting sequential protection action experiments; Acknowledging that there is no anomaly in the protective manifestation circuit; Acknowledging the balance of the output voltage of the inverter when operating independently.

More on that
Mitsubishi servo motor one-button adjustment function Mitsubishi servo motor one-button adjustment function

In the MR Configurator2 servo commissioning software, Mitsubishi has developed a "one-button adjustment" function to solve the problem of rigid noise of servo motors, as follows: 1. Set PA08 to 0003 and adjust the gain to ...

Mitsubishi PLC has a built-in time adjustment step Mitsubishi PLC has a built-in time adjustment step

1. TWR (Time Write) command Instructions to write time presets to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps. The work of the directive ...

Mitsubishi servo controller AL512 alarm Mitsubishi servo controller AL512 alarm

1. The acceleration and deceleration time constants are at fault. Solution: Increase the acceleration and deceleration time constants to check whether it is normal. 2. The torque constraint value is abnormal. Solution: Increase the torque constraint value to investigate whether it returns to normal. ...

Mitsubishi inverter pre-use debugging method Mitsubishi inverter pre-use debugging method

1. No-load energizing test of Mitsubishi inverter. 1. Ground the ground terminal of the Mitsubishi inverter. 2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch. 3 Check whether the factory display window of the Mitsubishi inverter is normal, if it is not correct.

Mitsubishi PLC and computer communication setup method Mitsubishi PLC and computer communication setup method

After opening the Mitsubishi PLC programming software, select your connection method from the menu "Online" > "Transfer Settings". 1. Connect the Mitsubishi PLC to the computer first. 2. Right-click on "My Computer" and select "Handle"...

PLC Reasonable Programming to Eliminate Misoperation - Mitsubishi PLC Reasonable Programming to Eliminate Misoperation - Mitsubishi

(1) Eliminate finger tremor: use the differential instruction DIFU (13) to retrieve the rising edge of the button to send the electrical signal, and the PLC only executes it once in an execution cycle, and then prevent such misoperation; (2) Unconscious operation: (1) Optimize the display function and use different fingers...

Mitsubishi inverter FR-E024-0.75K repair Mitsubishi inverter FR-E024-0.75K repair

Type: FR-E024-0.75K Fault: The boot cannot be started Maintenance: This machine does not provide any symptom information, and the display screen shows an "E.THT" error when the motor is to be started after powering on. Check the instructions refer to the ...

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation. ...

Mitsubishi servo motor shaft failure causes and solutions Mitsubishi servo motor shaft failure causes and solutions

1. The cause of the failure (1) Unreasonable mechanical design leads to excessive radial load force; (2) The load side is stuck, or the moment of severe overload; (3) The motor and reducer are not centered when installed; 2. Fault cleaning ...

Manipulator Fault Repair - Mitsubishi Robot Manipulator Fault Repair - Mitsubishi Robot

1. Speak before you start With regard to defective electrical equipment, it is necessary not to rush to start, but to inquire about the passage and defective phenomena that cause defects. For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each electrical department ...

How to deal with Mitsubishi PLC failures - Mitsubishi How to deal with Mitsubishi PLC failures - Mitsubishi

01. Base system problem In Mitsubishi PLC, binary, octal, decimal 10, hexadecimal, 2-10 (BCD), etc., we need to master the conversion of 2-8 base. 2-8, the binary number is remembered from the back, every 3 dividends in a group, each group is separated into 8 bases, such as 1 ...

The role of Mitsubishi inverters The role of Mitsubishi inverters

1. Overvoltage maintenance The output of the motor inverter has the function of voltage detection, and the inverter can actively adjust the output voltage so that the motor does not bear the overvoltage. Even if the output voltage adjustment fails and the output voltage exceeds 110% of the normal voltage, the inverter will stop to maintain the motor.

Mitsubishi PLC control system electroplating production line design Mitsubishi PLC control system electroplating production line design

Planning PLC control system control requirements for electroplating production line: 1) SQ1-SQ4 is the driving advance and retreat limit switch, and SQ5-SQ6 is the upper and lower limit switches. 2) The workpiece is lifted to SQ5 to stop, and the car is driven to SQ1 to stop.

The principle of Mitsubishi servo motor heating The principle of Mitsubishi servo motor heating

The motor of the core and winding coil is what we commonly see in our daily life, and what is the heating principle of this Mitsubishi servo motor by comparing it with other motors? We know that the winding has resistance, and the loss will occur when energized, and the size of the loss is proportional to the square of the current of the resistance.

Mitsubishi inverter fault judgment method Mitsubishi inverter fault judgment method

1. UVT problem UVT is an under-voltage problem, and I believe that many customers will still encounter such problems in use. The common undervoltage detection point of Mitsubishi inverter is the voltage on the DC bus side, and a low voltage value is sampled after the voltage division of the large resistance resistor, which is compared with the standard voltage value ...

The impact of Mitsubishi inverters on the quality of the power grid The impact of Mitsubishi inverters on the quality of the power grid

In the case of impact loads such as electric welding machines, electric arc furnaces, rolling mills, etc., the voltage often flickers; In a workshop, when there are multiple Mitsubishi inverters and other capacitive rectifier loads working, the harmonics that occur are very serious pollution about the quality of the power grid, and there is also considerable damage to the equipment itself.

Mitsubishi PLC main maintenance and overhaul content points Mitsubishi PLC main maintenance and overhaul content points

The main content of the protection and maintenance of Mitsubishi PLC Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...

Mitsubishi PLC advantages Mitsubishi PLC advantages

Discrete control and motion control, Mitsubishi's instructions are abundant, there are dedicated positioning instructions, control servo and stepping are easy to complete, to complete some messy action control is also Mitsubishi's strength, and Siemens is weaker in this area, there is no special instruction, do servo or step positioning control is not ...

Mitsubishi PLC's communication inspection method Mitsubishi PLC's communication inspection method

When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port. ...

Mitsubishi servo system failure problem Mitsubishi servo system failure problem

The origin position is incorrect, and the encoder debugs/zeros the bit Replacement bearings, bearing groove wear, rotor cracking, shaft cracking Gear groove wear The magnet bursts steel, the magnet falls, gets stuck and doesn't move Encoder wear, code ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top