Mitsubishi Q series PLC and GX Works2 connection method

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

01 USB connection

USB connection requires the device USB driver, generally the device will be actively driven after the installation of GX Works2 software, but at a single time due to anti-virus software or system reasons, or the device may not be available, then we need to manually drive the device to the accounting machine. You can find out the specific device method by yourself.

The USB interfaces of different CPUs are also different, some are square USB, the scientific name is TYPE-B, and there is a trapezoidal USB port, the scientific name is Mini-B, which is a little smaller than the square port;

If you use USB connection, you can directly set it to USB connection, and you don't need to select the COM port like FX3U, just select USB directly.

02 The CPU comes with an Ethernet port connection

First of all, use the CPU's built-in Ethernet port to connect, and select the three options of computer side-programmable controller side-other stations in turn;

Among them, the accounting side refers to the connection method of our computer, and the selection of Ethernet Board generally refers to the network card of the accounting machine;

On the programmable controller side, select PLC Module, which refers to the CPU component body.

Other selection, select No Specification, which refers to accessing this site, that is, the CPU itself;

Then, double-click the PLC Module button again to enter the PLC side setting;

There are two situations here, one is that the computer is directly plugged into the network cable to the CPU, which does not need to set the IP address to be connected;

The other is through the hub, that is, the switch for connection, here you need to set the IP address, to be common with the IP of the built-in Ethernet port of the CPU, here you can find through the built-in Ethernet PLC on the search network, the IP address will be displayed;

Ethernet IP to PLC parameters;

                               Mitsubishi Q series PLC and GX Works2 connection method

03Communication via Ethernet module

Mitsubishi's Ethernet modules communicate with third-party Ethernet devices, and through switches, they can communicate with many devices, and of course with GX Works2.

First of all, set up the Ethernet module, here added three Ethernet modules, separate from different communications, some are dedicated Ethernet modules, such as MES communication, and video communication, and some Ethernet modules are universal, mainly used to communicate with touch screen, computer debugging, here the third network card is with the touch screen and debugging communication, pay attention to the network number is 1, station number is 1;

Click Run Settings, set the IP of the Ethernet module, and click Set to complete when the setting is finished;

If you want the computer to communicate through GX Works2, you want to add MELSOFT connection, only one computer is allowed to connect to one channel, if you want to allow multiple people to debug the connection at the same time, then set up a few more channels;

After the parameters are saved, they are downloaded to the PLC through USB connection or built-in Ethernet module connection, and then the Ethernet connection method can be used.

QJ71E71 create a new connection method, double-click to enter

Click the connection method Ethernet Board on the computer side, and set the network number and station number, the network number is common to the Ethernet module, and the station number is not common to the Ethernet module.

On the PLC side, select the Ethernet Module, set the station number and IP address, and the station number here should be the same as the station number of the Ethernet module.

Click on the other two items to complete the setting;

Click on the communication test, and it is now connected to the PLC;

After setting the connection channel as the default, GX Works2 will use it as the default connection method to communicate with the PLC in the future.

More on that
The difference between the performance of Mitsubishi servo motor and stepper motor The difference between the performance of Mitsubishi servo motor and stepper motor

First, the control accuracy is different The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors with smaller step angles after subdivision. Communicate the control of servo motor ...

The principle of Mitsubishi servo motor heating The principle of Mitsubishi servo motor heating

The motor of the core and winding coil is what we commonly see in our daily life, and what is the heating principle of this Mitsubishi servo motor by comparing it with other motors? We know that the winding has resistance, and the loss will occur when energized, and the size of the loss is proportional to the square of the current of the resistance.

Mitsubishi Electric begins research and development of a Mars satellite probe probe Mitsubishi Electric begins research and development of a Mars satellite probe probe

TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...

Precautions for the use of Mitsubishi servo motor with brake Precautions for the use of Mitsubishi servo motor with brake

1. Occasions with brake servo motors: The servo motor is mainly loaded by the motor shaft, assuming that the load driven by the motor shaft is vertical, after the whole control system is powered off, the load on the servo motor shaft will be driven to run down under the action of gravity, so that ...

PLC Processor Performance Test – Mitsubishi PLC Processor Performance Test – Mitsubishi

The processor performance test should be carried out in accordance with the requirements of the system manual, to ensure that the system has the function described in the manual, and is stable and reliable, including the system communication, backup battery and other special modules to view. Redundancy testing is necessary for systems with redundant equipment. i.e. the redundant design ...

The role of PLC power module - Mitsubishi The role of PLC power module - Mitsubishi

Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...

Mitsubishi servo system failure problem Mitsubishi servo system failure problem

The origin position is incorrect, and the encoder debugs/zeros the bit Replacement bearings, bearing groove wear, rotor cracking, shaft cracking Gear groove wear The magnet bursts steel, the magnet falls, gets stuck and doesn't move Encoder wear, code ...

Mitsubishi PLC main maintenance and overhaul content points Mitsubishi PLC main maintenance and overhaul content points

The main content of the protection and maintenance of Mitsubishi PLC Although the failure rate of PLC is very low, the control system composed of PLC can operate stably and reliably for a long time, and it is essential to protect and view it alone. Generally, every six months ...

Mitsubishi PLC adjusts the built-in time Mitsubishi PLC adjusts the built-in time

1. TWR (Time Write) command Write the time preset value to the built-in real-time clock: Clock information is written to the TWR (Time Write) command. The sequence number of the action instruction is FNC167, [S ·] T, C and D can be used, and only 16-bit operations can be used, accounting for 5 program steps. The work of the directive ...

The cause of the failure caused by OC - Mitsubishi inverter The cause of the failure caused by OC - Mitsubishi inverter

1. Aging of drive circuit Due to the long-term use, it will inevitably lead to the aging of components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm often appears as soon as it is running. ...

The inverter completes the multi-speed function - Mitsubishi The inverter completes the multi-speed function - Mitsubishi

The inverter can be preset with a number of different speed points, and then complete the scheduling of multiple speed stages. The specific completion method is as follows: You can set a number of different speed points in the VFD, and you can generally set the maximum speed, minimum speed, and several center speed points. According to the needs, choose ...

Mitsubishi FR-E800 product model introduction Mitsubishi FR-E800 product model introduction

1、3相200V FR-E820-[]K (E)   FR-E820-0.1K、FR-E820-0.2K、FR-E820-0.4K、FR-E820-0.75K、FR-E820-1.5K、   FR-E820-2.2K、FR-E820-3.7K、FR-E820-5.5K、FR-E820-7.5K、FR-E820-11K、 ...

Mitsubishi Electric develops technology for high-power-density converters with embedded components Mitsubishi Electric develops technology for high-power-density converters with embedded components

TOKYO, March 25, 2020 – Mitsubishi Electric Corporation (TSE: 6503) today announced that it has developed a new technology that integrates power devices, passives, sensors, and other embedded components on the same substrate and performs the dispensing at 100kW (continuous) power.

Introduction to the capacitive role of Mitsubishi inverter Introduction to the capacitive role of Mitsubishi inverter

Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles. ...

Mitsubishi PLC commonly used circuit programming application Mitsubishi PLC commonly used circuit programming application

1. Self-locking and interlocking circuits 1) Self-locking circuit: The self-locking circuit is often used for the start-stop control of the motor. Press the start button X0 motor to start running, release the start button to keep the motor running, press the stop button X1 motor to stop running. 2) Interlock ...

Analysis of PLC and inverter connection problems - Mitsubishi Analysis of PLC and inverter connection problems - Mitsubishi

When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1. PLC switch command signal input Inverter input ...

Application of Mitsubishi FX PLC in speed measurement Application of Mitsubishi FX PLC in speed measurement

[Example] a motor is equipped with an optical encoder (the optical encoder is coaxially installed with the motor), and the FX2N-32MT is used to measure the speed of the motor. 【Solution】 Because the photoelectric encoder is coaxially installed with the motor, the ...

Mitsubishi inverter capacity selection Mitsubishi inverter capacity selection

The capacity (non-functional) of the Mitsubishi inverter for the drive motor can be understood from the change in energy flow determined by the operation method. 1. When accelerating or operating at constant speed The efficiency of the inverter is the output current, that is, how much current the inverter can provide to the motor. Frequency converters ...

Mitsubishi servo motor is now commonly used Mitsubishi servo motor is now commonly used

1. Torque control: Torque control is based on external simulation simulation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load on the motor shaft is less than 2.5Nm, ...

PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi PLC control cabinet design and use to meet the heat dissipation requirements - Mitsubishi

The PLC control cabinet is the final level of equipment in the power distribution system. It mainly protects, supervises and controls the entire circuit, which is convenient for unified management. The power distribution cabinet is a kind of equipment that can reasonably distribute electrical energy and make the circuit easy to open and close. But because it is a circuit device, the requirements for the level of safety protection ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top