Senlan inverter chemical industry air compressor application precautions

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

1. Due to the large moment of inertia of the air compressor, the capacity of the inverter should be determined according to the specific working conditions and the operating current of the site.

                                 Senlan inverter chemical industry air compressor application precautions

2. The pressure sensor should be installed on the gas tank in a place where the pressure change is not relatively drastic. In order to avoid interference, the signal of the pressure sensor should be 4-20mA current signal as much as possible, and the transmission line should be shielded with a double-core shielded wire.

3. There should be two control modes in the control system of the inverter: open-loop and closed-loop, so as to facilitate debugging and use under special circumstances.

4. Because the air compressor is not allowed to work in the low-frequency state for a long time, the operation at the low frequency not only has poor stability, but also is prone to surge, on the other hand, it also makes the lubrication of the cylinder body worse, which will accelerate the wear, so a reasonable, effective and safe lower limit of the working frequency should be set. The specific setting should be patiently and meticulously adjusted according to different working conditions, different use conditions and requirements.
More on that
Precautions for the use of industrial touch screen all-in-one machine Precautions for the use of industrial touch screen all-in-one machine

1. The contact screen all-in-one machine adopts the new contact identification technology, and the user only needs to touch it lightly on the contact screen without passing the pressure sensing to complete the operation. Care must be taken not to use too much force or sharps to scratch the surface of the contact screen. ...

Inverter control scheme for fan and water pump - Senlan inverter Inverter control scheme for fan and water pump - Senlan inverter

There are many control methods for inverters for fans and pumps, which can be selected according to specific conditions. Here are a few common scenarios. (1) Manual adjustment This is the simplest control method, that is, the operator instructs according to the instrument, ...

The main step of inverter debugging - Sunland inverter The main step of inverter debugging - Sunland inverter

Investigation of the function of the inverter system Before debugging the frequency converter, it is necessary to carefully read the operation instructions and related information of the inverter to be debugged to understand the application environment and precautions. Especially before the inverter is energized, it is necessary to carefully observe and see if the inverter has obvious problems.

Application of Sunland inverter in sugar separator Application of Sunland inverter in sugar separator

First, the operation of the machine before the technical transformation The sugar separation process of a sugar factory in Yunnan uses centrifugal dehydration method. The separation machine is mainly composed of a cone drum and a drive motor, and the motor shaft is directly connected to the bowl. Solid sugar crystallized from a high concentration of sugar water, in a cone bowl ...

Suppression method of electromagnetic interference of inverter - Sunland inverter Suppression method of electromagnetic interference of inverter - Sunland inverter

The operating principle of the inverter determines that it will have a certain disturbance, which may bring EMC (electromagnetic compatibility) problems to the equipment or system, and the inverter, as an electronic device, will also be affected by external electromagnetic disturbance. Below...

Hope Senlan inverter selection Hope Senlan inverter selection

Hope Sunland inverter is a high-performance inverter product, which has high operational reliability, high energy efficiency, strong control performance and long service life. Hope Sunland inverter has been widely used in industrial process production control, machinery control, water treatment, construction and transportation and other fields. This article will start with ...

Precautions for using inverter - Sunland inverter Precautions for using inverter - Sunland inverter

A frequency converter (VFD) is an electrical energy control device that converts a power supply to another frequency by using the on-off effect of power semiconductor equipment. It can realize the soft start, frequency conversion speed regulation, improved operation accuracy, power factor, overcurrent/overvoltage/overload protection of AC asynchronous motor, etc.

Selection and capacity matching of inverter - Senlan Selection and capacity matching of inverter - Senlan

1. Select the inverter according to the load characteristics Second, when selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the extra power of the motor can only be used as a reference. Secondly, it should be fully considered that the output of the inverter contains higher harmonics, which will form the power factor of the motor.

Measures to prevent overvoltage of inverter - Sunland inverter Measures to prevent overvoltage of inverter - Sunland inverter

Depending on the cause of overvoltage, the countermeasures adopted are different. Regarding the overvoltage phenomenon that occurs in the parking process, if there is no special requirement for the parking time or direction, then the extension inverter deceleration time or free parking method can be selected to solve it. The so-called free parking ...

Hope Sunland inverter fault code Hope Sunland inverter fault code

Hope Sunland inverter part of the fault code Er.ocb (1) Overcurrent at the moment of starting: There is a short circuit inside the motor There is a short circuit in the motor wiring The starting voltage is too high Check the motor and wiring Check the motor wiring Seek service Check the torque ...

Motor starting mode - Senlan inverter Motor starting mode - Senlan inverter

The inverter is a motor control (speed regulation) device that uses the on-off effect of power semiconductor devices to convert the power frequency power supply to another frequency. Composition 1: 1. Rectifier unit: convert the communication electricity with fixed operating frequency into DC ...

Rapid selection method of low-voltage inverter - Sunland inverter Rapid selection method of low-voltage inverter - Sunland inverter

First, according to the classification and selection of inverters 1. Inverters can be divided into general-purpose inverters and special inverters. 2. General-purpose inverters are mainly used in: general fan pumps (referring to inverters that only drag a single fan or pump) loads, mechanical loads, and loads requiring high overloads.

Overvoltage treatment method caused by load input side - Senland Overvoltage treatment method caused by load input side - Senland

(1). The deceleration time of the frequency conversion parameter is increased or free parking is adopted Assuming that the overpressure phenomenon is present in the parking process, the process has no parking requirements for the parking time or direction, and the deceleration time can be increased appropriately. The reason for the overvoltage in the parking process is that after the frequency conversion announces the deceleration command, the motor ...

Repair and maintenance of Sunland inverter Repair and maintenance of Sunland inverter

The input and output currents of the inverter contain many higher harmonic components. In addition to the lower harmonics that can constitute the reactive power loss of the power supply, there are many harmonic components with high frequencies. They will transmit their own energy in various ways, forming a positive impact on the inverter itself and other equipment.

The reason for the explosion of the inverter module - Senlan inverter The reason for the explosion of the inverter module - Senlan inverter

1. Condensation The temperature difference in the workshop is large, and the inside of the inverter presents condensation. 2. Impact load. The load fluctuates greatly, and the output current of the inverter suddenly increases, resulting in module damage. 3. The inverter is overloaded in the start, ...

The overload capacity of the dry-type transformer - Sunland inverter The overload capacity of the dry-type transformer - Sunland inverter

Dry-type transformer is a kind of power equipment, and under normal circumstances, dry-type transformer also requires a certain amount of overload, that is, the workload beyond its working ability. So what about the overload of dry-type transformers and how to influence them? ...

Introduction to the speed regulation mode of inverter motor - Senlan Introduction to the speed regulation mode of inverter motor - Senlan

1. Mechanical speed regulation form There are three methods of mechanical speed regulation: electromagnetic clutch, hydraulic coupling, and viscous clutch. Among them, the hydraulic coupling device is widely used, that is, a hydraulic coupling device is connected in series between the motor and the load, and the concave and convex liquid level is used to adjust the hydraulic coupling between the motor and the load.

At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter At the physical level, the stable operation of the inverter is guaranteed-Senlan inverter

For the most popular electrical control equipment inverter (Variable-frequency Drive, VFD), as a precision electronic industrial control equipment, in order to run smoothly for a long time, we, as professional and technical personnel, need to be on the VFD device or before the operation.

The inverter controls the speed of the AC motor - Senland The inverter controls the speed of the AC motor - Senland

The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the operating principle of the motor. Since the number of poles is not a successive value (a multiple of 2, e.g. 2,4,6), ...

Introduction of Sunland inverter Introduction of Sunland inverter

1. Obtain accurate motor parameters from low to high parameters at different frequencies, and establish motor models of corresponding frequency bands in different frequency segments, so that the inverter can control the motor from low to high. 2. V/F control (1) It is possible to select 15 pre-set V/...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top