1. Obtain accurate motor parameters from low to high parameters at different frequencies, and establish motor models of corresponding frequency bands in different frequency segments, so that the inverter can control the motor from low to high.

2. V/F control

(1) Able to select 15 pre-set V/F curves suitable for use;

(2) Any V/F curve can also be set;

(3) The 15 types of V/F curves can be summarized into the following types:

1) Constant torque characteristics: it is a general use of curves, like a linear conveyor belt, and a constant torque application place that has nothing to do with speed;

2) Decreasing torque characteristics: such curves are used in load situations where the speed is 2 power-related like fans and water pumps;

3) High starting torque: the wiring interval between the inverter and the motor is long (about 100m or more), and the output torque is required to be large (elevator load) when starting, and an AC reactor is inserted in the input or output of the inverter, and the motor below the motor is used to run with a larger ratio;

4) Constant output power operation: It is the curve of the frequency above 50Hz to make it run, and the frequency above 50Hz is the constant voltage.

                            Introduction of Sunland inverter

3. Two sets of motor parameters

Able to set two sets of intact motor parameters independently, and can use multi-function external terminals to select motors,

It has a variety of protection functions such as over-current, over-voltage, over-temperature, over-load and under-voltage. When a fault occurs, the inverter will immediately alarm and jump away, the corresponding fault type will be displayed on the LED monitor, and the motor will automatically stop rolling. When the fault is eliminated, press the STOP key or enter the RST reset command of the control circuit terminal to release the alarm jump state. Overvoltage: 1. Fault code: E002 (overvoltage when accelerating), E003 (overvoltage at constant speed), E00A (overvoltage when stopping), E00B (overvoltage when decelerating) 2. Possible causes: (1) The input voltage is abnormal; (2) The deceleration time is too short; (3) The selection of braking equipment is not suitable; (4) The load moment of inertia is too large. 3. Solution: (1) Check the input power supply; (2) Set the deceleration time from the beginning; (3) Select braking equipment from scratch; (4) Reduce the moment of inertia. Undervoltage: 1. Fault code: E0012, or cause: (1) The input voltage is abnormal; (2) There are large-capacity loads running on the same line; (3) Internal faults of the inverter; 3. Solution: (1) Check the input power supply; (2) reduce the line load capacity; (3) Contact the inverter repairer, dealer or manufacturer. Overcurrent: 1. Fault code: E004 (overcurrent when accelerating), E005 (overcurrent at constant speed), E006 (overcurrent when decelerating) 2. Possible reasons: (1) Short circuit between motor connection terminals; (2) Sudden load change; (3) The acceleration time is too short; (4) Motor stalling; (5) Internal defects of the inverter; 3. Solution: (1) Check the output line and load; (2) reduce the line load capacity;

More on that
The cause of the leakage problem of Sunland inverter The cause of the leakage problem of Sunland inverter

1. The cause of inverter leakage According to the inverter to control the operation of the motor, the three-phase electricity is supplied to the inverter bridge (IGBT) through the filter capacitor through the rectification, and then the operation of the motor is controlled by the three-phase electricity with adjustable output frequency and voltage of the inverter. We all know that the three-phase stator winding of the motor ...

Effect of inrush current on inverter - Senlan Effect of inrush current on inverter - Senlan

In the process of repairing the inverter, we can find that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-loop rotor, the current impact will inevitably have a negative impact on the motor, the inverter (Variable-frequency ...

The inverter's requirements for the surrounding environment - Senlan The inverter's requirements for the surrounding environment - Senlan

1) Operating temperature: The inverter is a high-power electronic component, which is simply affected by the operating temperature, and the general temperature requirement is 0 - 55. However, in order to ensure the safety and reliability of the operation, it is necessary to consider freeing up space when using, and it is best to control it below 40. The inverter generally requires the device to operate ...

Senlan inverter motor failure analysis Senlan inverter motor failure analysis

1. The motor slows down too slowly 1) If the deceleration time is set too long, reduce the deceleration time 2) Install a braking resistor 3) Add DC braking 2. The motor is overheated 1) The load is too large, and the practical moment has exceeded the ...

The difference between inverter and inverter power supply - Senlan inverter The difference between inverter and inverter power supply - Senlan inverter

What is an inverter power supply? A variable frequency power supply converts the alternating current from the main power supply from AC→DC→AC to a pure sine wave. The output frequency and voltage can be adjusted within a specific range. Unlike the inverter governor used for the speed control of electric motors, it is also different from the general AC power supply. Aspiring AC ...

Heat dissipation method of small-capacity inverter - Senlan Heat dissipation method of small-capacity inverter - Senlan

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The dragging objects of this type of inverter are mostly household air conditioners, CNC machine tools, etc., and the power is small. ​ ...

The method of heat dissipation of small-capacity inverter - Sunland inverter The method of heat dissipation of small-capacity inverter - Sunland inverter

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The drag targets of such inverters are mostly household air conditioners, CNC machine tools, etc., and the power is small. Still...

The reason for the low output voltage of the inverter - Senlan inverter The reason for the low output voltage of the inverter - Senlan inverter

1. The power supply voltage is low The solution is to preset the active voltage adjustment function of the inverter, so that when the frequency is low and the rated frequency is dry, the inverter has the function of active voltage stabilization, and if the output voltage is low, the inverter will actively increase the output voltage ...

Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan

Capacitor damage is the highest problem in electronic devices, especially electrolytic capacitors. Capacitor damage is manifested in: 1. Capacity becomes smaller, 2. Capacity is completely lost, 3. Leakage, 4. Short circuit. Electricity...

Causes and treatment methods of inverter inverter module damage - Senlan Causes and treatment methods of inverter inverter module damage - Senlan

Most of the damage of the inverter module is due to the damage of the driving electric, which causes the two switching devices on one bridge arm to be turned on at the same time. Inverter inverter power module damage is a common problem in other inverter equipment such as vector inverter or energy-saving inverter.

Common brand inverter modification power method - Senlan inverter Common brand inverter modification power method - Senlan inverter

What are the advantages of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters. ...

The eight forbidden areas of inverter control loop wiring - Senlan The eight forbidden areas of inverter control loop wiring - Senlan

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This will help prevent the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Analysis of the causes of bearing damage - Hope Sunland Analysis of the causes of bearing damage - Hope Sunland

In the process of using bearings, often due to some external factors cause some wear in the rotation of the bearing, and these bearing wear will be completely damaged in the addition of day by day, which requires our maintenance personnel to replace the bearing, and generally form a bearing.

Inverter-related knowledge - Senlan inverter Inverter-related knowledge - Senlan inverter

1. What does open-loop mean in the use of inverters? The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...

Hope for an application example of Sunland inverter Hope for an application example of Sunland inverter

Industrial process control: It is expected that Sunland inverters are widely used in industrial process production control, such as conveyors, tugboats, air compressors, pumps, and fans and other equipment in various control systems. Mechanical control: It is expected that Sunland inverters are widely used in mechanical control, such as ...

The difference between vector and general use of frequency converter The difference between vector and general use of frequency converter

1. The control accuracy of the vector type is higher than that of the general type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, and is suitable for use in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If it is used in some of the more common fields ...

Limit switch wiring method - hope Senlan Limit switch wiring method - hope Senlan

Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc. ...

Senlan direct torque control principle Senlan direct torque control principle

The direct torque control (DTC) function of the inverter is another high-performance communication frequency conversion speed regulation system developed after vector control. In the mid-80s of the 20th century, the German scholar Depenbrock proposed the theory of direct torque control in 1985, and his idea was to combine the electric motor and the inverter.

What are the protection functions of the inverter - Sunland inverter What are the protection functions of the inverter - Sunland inverter

1. Incoming line maintenance Incoming maintenance is the maintenance of the user's inlet end and inverter, including lightning protection maintenance, grounding maintenance, phase loss maintenance, inverted phase maintenance, unbalance maintenance, overvoltage maintenance, transformer maintenance and so on. These maintenance devices are generally installed at the input of the inverter ...

About the basic selection of Hope Sunland inverter About the basic selection of Hope Sunland inverter

It is hoped that Sunland low-voltage inverter can be divided into four series: 1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top