Selection and capacity matching of inverter - Senlan

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

1. Select the inverter according to the load characteristics

Second, when selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the extra power of the motor can only be used as a reference. Secondly, it should be fully considered that the output of the inverter contains higher harmonics, which will form the power factor and efficiency of the motor.

                            Selection and capacity matching of inverter - Senlan

3. When the inverter wants to run with a long cable, the inverter should be enlarged by one gear or the output reactor should be installed at the output end of the inverter.

Fourth, when the inverter is used to control several motors connected in parallel, it must be considered that the sum of the length of the cable from the inverter to the motor is within the allowable range of the inverter.

5. For some special applications, such as high ambient temperature, high switching frequency, high altitude, etc., it will cause the capacity reduction of the inverter, and the inverter needs to be enlarged by one gear.

6. When selecting the inverter for high-speed motors, it should be slightly larger than the inverter of ordinary motors.

7. When the inverter is used in a pole-changing motor, sufficient attention should be paid to selecting the capacity of the inverter, so that its maximum additional current is below the additional output current of the inverter.

8. When driving the explosion-proof motor, the inverter does not have an explosion-proof structure, and the inverter should be set up outside the dangerous place.

9. When the frequency converter is used to drive the gear reducer motor, the scope of use is limited by the lubrication method of the gear rolling part. Do not exceed the maximum speed tolerance.

10. When the inverter drives the wound rotor asynchronous motor, most of the existing motors are used. It is easy to overcurrent tripping due to ripple current, so it is necessary to choose an inverter with a slightly larger capacity than usual.

11. When the inverter drives the synchronous motor, the output capacity is reduced by 10%-20% compared with the power frequency power supply.

12. For compressors, vibrators and other loads with large torque fluctuations and hydraulic pumps and other peak loads, the power frequency operation status should be understood, and the inverter with additional output current greater than its maximum current should be selected.

13. When the inverter controls the roots blower, because its starting current is very large, it is necessary to pay attention to whether the capacity of the inverter is large enough when selecting the inverter.

14. When selecting the inverter, it is necessary to pay attention to whether its protection level matches the situation on site.

15. Single-phase motors are not suitable for inverter drive.

If there is only the high reliability of the inverter body, and the inverter selection and capacity matching are not appropriate, the frequency conversion speed regulation system composed of it cannot achieve high reliability, or even work, so how to ensure the normal and efficient operation of the frequency conversion adjustment system?

We want to make sure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct type of inverter is selected. The general criterion is what the nature of the load characteristics with what characteristics of the inverter.

(1) Constant torque production equipment - within the speed regulation range, the load torque is fundamentally constant. A frequency converter with constant torque function should be selected. It can only be overloaded to maintain 150% additional current for 1 minute.

(2) Square torque production equipment - within the speed regulation range, the load torque is proportional to the square of the speed, that is, M∝n2, centrifugal fan, water pump is its typical representative. The inverter with M∝n2 characteristics can have a small overload, 110%-120% additional current overload for 1 minute,

(3) Constant power load production equipment - within the speed regulation range, the speed is low and the torque is large; The high speed and small torque, i.e. M? NC (constant). Typical equipment such as machine tools and winding weaves.

More on that
Sunland proposed a multi-machine parallel high-voltage shore power supply system solution Sunland proposed a multi-machine parallel high-voltage shore power supply system solution

Air pollution in port cities mainly comes from cargo loading and unloading operations and emissions from ships calling at ports; Shore power connection refers to the closure of the auxiliary engine during the port of the vessel, and the shore power is supplied by the port. At 9:08 on December 25, 2018, the world's first ...

Misunderstandings and countermeasures of industrial control inverter - Senlan Misunderstandings and countermeasures of industrial control inverter - Senlan

Today, with the rapid development of science and technology, with the continuous improvement of industrial automation, inverters have also been widely used. Choosing a suitable inverter is very important to ensure the normal and efficient work of the inverter, but in practice, it is necessary to pay attention to some ...

Heat dissipation method of small-capacity inverter - Senlan Heat dissipation method of small-capacity inverter - Senlan

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The dragging objects of this type of inverter are mostly household air conditioners, CNC machine tools, etc., and the power is small. ​ ...

Hope Sunland grid-connected PV inverter Hope Sunland grid-connected PV inverter

Grid-connected photovoltaic inverter is one of the core components of solar photovoltaic power generation system, the main types are: central inverter, modular inverter, micro inverter, DC ...

Inverter overcurrent protection solution - Senlan Inverter overcurrent protection solution - Senlan

1. Causes of overcurrent There are many reasons for the occurrence of overcurrent, including soft and hard problems. 1. Causes of soft failures When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...

Practical installation precautions for frequency converters Practical installation precautions for frequency converters

When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor. A 3% impedance line reactor should be used to reduce power line transient voltages caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...

Repair and maintenance of Sunland inverter Repair and maintenance of Sunland inverter

The input and output currents of the inverter contain many higher harmonic components. In addition to the lower harmonics that can constitute the reactive power loss of the power supply, there are many harmonic components with high frequencies. They will transmit their own energy in various ways, forming a positive impact on the inverter itself and other equipment.

General technical specifications for Sunland inverter SB200 series General technical specifications for Sunland inverter SB200 series

Input rated voltage, frequency 3 phase: 380V, 50/60Hz allowable scale Voltage: 320-420V; Voltage unbalance: <3%; Frequency: 47 - 63 Hz Output output voltage 3 phases, 0V - input voltage, error less than 5% Output frequency scale ...

Inverter device inspection and maintenance work steps Inverter device inspection and maintenance work steps

1. Preparation process: Abort the device and admit that the motor is completely aborted. Press the stop button on the operator panel to stop the operation. Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that it is indeed disconnected and that it does not ...

According to the load characteristics, choose the inverter - Senland According to the load characteristics, choose the inverter - Senland

The types of production machinery are complex, the functional and process requirements are different, and the torque characteristics are also different, therefore, before the application of the inverter, the first thing is to understand the nature of the load carried by the motor, that is, the load characteristics, and then select the inverter and the motor. There are three types of loads: ...

Introduction to the inverter maintenance and energizing test - Senlan Introduction to the inverter maintenance and energizing test - Senlan

First, the inverter is not repaired and the power test is tested (1) Inverter repair test rectifier circuit At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T in turn.

Damage to the inverter power module of the inverter - Senland Damage to the inverter power module of the inverter - Senland

1. Discrimination The inverter power module mainly includes IGBT, IPM, etc., check whether the appearance has exploded, and whether there are ablation marks between the terminal and the connected printed board. Use a multimeter to check whether C-E, G-C, G-E have been passed, or use a multimeter to measure whether the resistance of P to U, V, W and N to U, V, W is inadequate.

Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line

In order to thoroughly implement the spirit of General Secretary Xi Jinping's important instructions that the economic power must be a maritime power, a shipping power, economic development, a strong country, and transportation, especially shipping, and the implementation of the outline for the construction of a transportation power, the port ship shore power system has become the standard for green ports.

The control mode of low-voltage general-purpose inverter - Sunland inverter The control mode of low-voltage general-purpose inverter - Sunland inverter

Voltage Space Vector (SVPWM) Manipulation Method: It is based on the premise of the overall generation effect of the three-phase waveform, with the intention of approximating the ideal circular rotating magnetic field trajectory of the motor air gap, generating the three-phase modulation waveform at one time, and controlling it by approaching the circle with inscribed polygons. In practice, ...

Inverter phenomenon detection method and judgment - Senlan Inverter phenomenon detection method and judgment - Senlan

1. The power-on trip or the main power terminal part of the inverter shows sparks. Disconnect the power cord, check whether the input terminal of the inverter is short-circuited, and check whether the DC side terminals P and N of the central circuit of the inverter are short-circuited. Perhaps the cause is a damaged rectifier or a short circuit in the central circuit. 2 ...

Hope Senland's introduction to the charging module Hope Senland's introduction to the charging module

The charging module is a DC charging module developed to meet the high voltage and high current of electric vehicles. The module has many advantages such as high efficiency, high power factor, high power density, and high reliability. The module selects the three-phase AC input method without a centerline. DC output voltages range from 250V to 750V ...

Inverter parameter setting method - Senlan Inverter parameter setting method - Senlan

1. Control method: i.e. speed control, rotation control, PID control, or other methods. After the control method is adopted, it is generally necessary to carry out static or dynamic identification according to the control accuracy. 2. Minimum operating frequency: That is, the minimum speed of the motor operation, the motor at low speed ...

Sunland low-voltage inverter division series Sunland low-voltage inverter division series

1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge, dehydrator, sewage treatment, HVAC, constant pressure water supply, constant temperature control, flow control and other industries, such as fans and pumps, ...

Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row Sunland won the "well-known brand of China's domestic inverter" for the fifth time in a row

On April 15, 2011, the "Century Tour of China's Automation Industry (CAIE2011)" was held in Beijing, and Sunland inverter was once again re-elected as "China's well-known brand of domestic inverter". Dr. Chen Bin, President of Continental Hope Group and Chairman of Hope Sunland Technology Co., Ltd., personally ...

Sunland attended the 2015 Industrial Automation Exhibition in Nuremberg, Germany Sunland attended the 2015 Industrial Automation Exhibition in Nuremberg, Germany

November 24, 2015 - November 26, 2015, "Germany Nuremberg Industrial Automation Exhibition" was successfully carried out at the Nuremberg International Exhibition Center in Germany, and it is expected that Sunland as a domestic professional inverter manufacturer also participated in the exhibition, in this exhibition, in addition to the usual SB70, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top