Mitsubishi CPU module engineering creation method
Start engineering tools, create projects.
[Establishment process]
1. Select the CPU module to be used in the "Model" item. In the "Programming Language" project, you can choose to use a programming language in your project. In this example, in order to illustrate in ladder language, select "ladder" and click the button.
2. Add the module tab screen for the CPU module and click the [Yes] button
[point]
A module tag is a tag that is defined in advance using the module's input and output signals, buffer memory, etc. When using module tags, you can create a program simply without having to pay attention to the internal address of the module.
|
More on that
|
Mitsubishi PLC command negation, empty operation and END, etc
Introduction to Mitsubishi PLC directives such as negation, air operation and END
The INV (Inverse) command is represented by a short 45° slash at the top of the ladder diagram, which negates the result of the operation before the execution of the instruction, and the result of the operation is 0 ...
|
|
Mitsubishi 5uplc monitors modbusTCP disconnect methods
First, Mitsubishi uses FX5U series PLC with serial port and built-in modbus communication protocol, so that we can easily communicate with third-party equipment. If it is a communication between Mitsubishi PLC and the inverter, the focus is on designing the parameters. The inverter is heavy, set the address, baud rate, check, etc., ...
|
|
Features of Mitsubishi PLC programming language
1. Graphical instruction structure: The program is expressed graphically, and the instructions are composed of different graphic symbols, which are easy to understand and remember. In the logic operation part, almost all manufacturers use a ladder diagram similar to the relay control circuit, which is easy to accept. More complex arithmetic operations, ...
|
|
Mitsubishi takes instructions and outputs instructions
1) LD (take instruction) A command to connect a normally open contact with the left bus, and every logic line that starts with a normally open contact is used with this instruction;
2) LDI (Reverse Instruction) A normally closed contact is connected to the left bus to the instruction, each ...
|
|
Precautions related to transportation control of lithium batteries - Mitsubishi
This Skills Brief introduces the United Nations requirements for lithium battery shipment controls and United States guidelines for lithium battery shipment controls.
In addition, the content shown in this skill newsletter will be discontinued as of March 2020.
...
|
|
Mitsubishi FR-A700 series inverter problem
1. Consultation question: FR-A700 series Mitsubishi inverter, the suffix is ending in -CA1, what kind of inverter?
Solution: The suffix -CA1 is a special model with take-up control.
2. Consultation question: FR-A ...
|
|
Mitsubishi FX2N Series Extended PLC Module Selection Chart
|
|
Introduction to the principle of Mitsubishi tension controller
The tension controller can be called the tension manipulator, which is generally equipped with magnetic powder brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the ability to give a certain amount of output through the tension manipulator ...
|
|
Introduction to the capacitive role of Mitsubishi inverter
Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many titles, the following introduces the meaning of some commonly used titles.
...
|
|
Installation and maintenance of Mitsubishi inverters
1. Mitsubishi inverter is more and more widely used because of a series of advantages such as wide speed regulation range, high speed regulation accuracy, fast dynamic response, high work efficiency, convenient operation and easy interface with other equipment. Because of the high common sense content of Mitsubishi inverter and the messy technology, how to use Mitsubishi inverter well...
|
|
The role of PLC power module - Mitsubishi
Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...
|
|
Mitsubishi servo motor shaft failure causes and solutions
1. The cause of the failure
(1) Unreasonable mechanical design leads to excessive radial load force;
(2) The load side is stuck, or the moment of severe overload;
(3) The motor and reducer are not centered when installed;
2. Fault cleaning
...
|
|
Methods for shortening the scanning cycle of PLC programs – Mitsubishi
1. Try to avoid using "double words" when you can use "words", and try to prevent using real numbers when you can use integers.
2. Give priority to the use of surplus (other than hardware connection) IB, IW, ID, QB, QW, QD, followed by M and S;
3. Try to prevent the transformation of data types, ...
|
|
The wiring steps of the input and output circuits of the Mitsubishi PLC
The wiring diagram steps of the input and output circuit of Mitsubishi PLC, there are generally three types in the wiring diagram of the input and output of the PLC, one is DC 12-24V input, and there is output, so what about the external input?
(1 ...
|
|
A brief description of Mitsubishi's PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. CC-Link fieldbus connection is selected, the number of wiring is greatly reduced, and the maintainability of the system is improved. Whereas...
|
|
Mitsubishi inverter setting parameter adjustment method
Mitsubishi inverter has many setting parameters, each parameter has a certain selection scale, and the inverter can not work normally due to improper setting of a single parameter in the application. Let's take a look at the Mitsubishi inverter parameter setting operation.
...
|
|
Query Error Code Method – Mitsubishi
Error Number (D8063): 6314
ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL)
Error content: Parallel operation string abnormal
Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...
|
|
How to write a holding circuit for Mitsubishi PLC
There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed once through the insistence circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit.
...
|
|
Mitsubishi inverter heat dissipation causes and countermeasures
1. Whether there is abnormal change in the sound during the operation of the equipment, including whether there is oscillation during the operation of the motor.
2. Whether the ambient temperature of the inverter installation is too high or too low, the working temperature is generally required to be in the range of -10°C - +40°C, and it is better to be about 25°C.
...
|
|
Mitsubishi servo motor code failure
1. Disadvantages of UVT
The common undervoltage detection point is the voltage on the DC bus side, and a low voltage value is sampled after dividing the voltage by the large resistance resistor, and the output voltage is normal signal, overvoltage signal or undervoltage signal after comparing with the standard voltage value. About Mitsubishi A500 series inverter voltage signal ...
|
|