1. Routine control is consistent with safety control
In the MELSEC-QS series, it is necessary to prepare a system for conventional control and a system for safety control. With the MELSEC iQ-R series of safe programmable controllers, it is possible to combine conventional and safe control into a single system.
In the MELSEC iQ-R series of safe programmable controllers, the modules for safe operation and conventional control can be used on the same board, thus saving space.
In addition, power modules, substrates, and network modules can be shared with modules for conventional control, reducing costs.
2. Consistency between routine communication and secure communication
In the MELSEC-QS series, two networks need to be built: CC-Link and CC-Link Safety. The MELSEC iQ-R series of safe programmable controllers can be used to mix conventional and secure communication via the CC-Link IE field network.
In the MELSEC iQ-R series of safe programmable controllers, conventional and secure communication can be achieved via the CC-Link IE field network, making it possible to mix conventional long-distance I/O modules with safe long-distance I/O modules. In addition, conventional Ethernet cables can be used, eliminating the need for special cables.
3. Productive progress
Responsiveness is improved by utilizing the high-performance safety programmable manipulator MELSEC iQ-R series and the CC-Link IE field network. (The safety response time is about 1/3 of the MELSEC-QS series.)
In addition, the MELSEC iQ-R series of safe programmable controllers has a program capacity of 40K steps for safe operation. (Approximately 3 times that of the MELSEC-QS series)
As a result, large-capacity programs can be processed at high speeds, improving the productivity of customers' systems.
|
More on that
|
Introduction of Mitsubishi servo motor
Servo motor refers to the engine that controls the operation of mechanical components in the servo system, and is a kind of auxiliary motor indirect transmission device. The servo motor can make the control speed, azimuth accuracy is very precise, and can convert the voltage signal into torque and speed to drive the control target. Servo motor rotor speed ...
|
|
Mitsubishi servo maintenance failure analysis
Major Failures and Analysis:
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
...
|
|
Mitsubishi PLC ladder programming method
Ladder concept: It is a ladder pattern composed of graphical symbols that indicate the programming elements inside the PLC.
Rules for writing ladders:
Suitable for the left bus, finally the right bus
The contacts should be drawn on the horizontal line, not ...
|
|
The cause of the failure caused by OC - Mitsubishi inverter
1. Aging of drive circuit
Due to the long-term use, it will inevitably lead to the aging of components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm often appears as soon as it is running.
...
|
|
Mitsubishi touch screen common faults and solutions
Fault 1: Mitsubishi touch screen contact deviation
Phenomenon: The direction of finger contact does not match the mouse arrow.
Analysis: When calibrating the orientation after installing the screwdriver, there is no vertical contact with the bull's-eye. Solution: Recalibrate the bearing.
...
|
|
Mitsubishi PLC's communication inspection method
When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port.
...
|
|
Mitsubishi PLC program lost backup program write method
The reasons for the loss of the PLC program are the lack of battery power supply for the user's saved program, the internal circuit of the PC, the motherboard burned out due to the impact of external high voltage such as lightning strikes, etc., which will be encountered in our PLC control system. For example, the old type of plc such as the FX2N series, which has been discontinued...
|
|
Maintenance method of Mitsubishi inverter
Electrical characteristics view
Mitsubishi inverters that have been running and placed for a long time, due to the influence of the environment and the aging of inverter equipment, it is necessary to check and maintain the electrical performance of Mitsubishi inverters regularly. A comprehensive review of the input, rectifier and inverter, DC input fuses found ...
|
|
Analysis of PLC and inverter connection problems - Mitsubishi
When the inverter is used to form an active control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1. PLC switch command signal input
Inverter input ...
|
|
PLC troubleshooting method - Mitsubishi
1. If the PLC stops in the middle of some outputs where the output is excited, then look for the signal that caused the next operation (input, timer, line, drum manipulator, etc.). The programmer will show the ON/OFF status of that signal.
...
|
|
Query Error Code Method – Mitsubishi
Error Number (D8063): 6314
ERROR MESSAGE: PARALLELLINKERROR (PARALLEL OPERATION COMMUNICATION ABNORMAL)
Error content: Parallel operation string abnormal
Method: Whether the power supply of the two PLCs is on, and whether the connection wires between the main machine and the parallel operation module are correctly connected ...
|
|
Programmable Controller System Design and Debugging Steps – Mitsubishi PLC
The main steps in the planning and commissioning of the programmable manipulator application system
(1) In-depth understanding and analysis of the process conditions and control requirements of the controlled target
a. The controlled target is a controlled mechanical, electrical equipment, production line or ...
|
|
The connection of the Mitsubishi inverter FR-A800
The connection of the Mitsubishi inverter FR-A800
|
|
Mitsubishi FX1N switching power supply fault repair
Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged).
Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.
|
|
Mitsubishi PLC set and reset command use example
1 SET Directive
The SET instruction is called an enthronement instruction. Its function is: to drive the coil, so that it has a self-locking function, and insists on the connection condition. In the diagram, when the moving contact X0 is closed, the SET command is executed to turn on the Y0 coil. After X0 is disconnected, the Y0 coil continues to insist on the ON condition, ...
|
|
Mitsubishi inverter FR-E700 series is selected
Q: When will I choose the E740 series inverter?
A: E700 is an economical and small inverter with high driving performance, with the function of holding the brake, and can also add options to expand the function, which can be used for transportation, lifting occupations, and has high cost performance.
Q: Mitsubishi inverter E740 should ...
|
|
Introduction to the selection conditions of Mitsubishi A840 series inverters
Q: When will I choose the A840 series inverter?
A: A800 series inverters are generally used in heavy-duty occupations, such as lifting occupations, mixer occupations will use A800 series. At the same time, it is a vector inverter, so customers need to do closed-loop speed control, torque control may ...
|
|
Mitsubishi inverter FR-A800 series selection
Q: When will the CS84 series inverter be selected?
A: CS80 series inverter belongs to the diversified function of small intelligent inverter, covering excitation control and general flux vector control, the volume is 57% of the same model, very fast, in some general functions can be used in this model ...
|
|
Mitsubishi PLC controls the control method of the inverter
1. Use the switching signal of PLC to control the inverter
The output point and COM point of the PLC (MR type or MT type) are directly connected to the STF (forward engine), RH (high speed), RM (medium speed), RL (low speed), and SG input ports of the inverter. The PLC can control the inverter through the program.
|
|
The built-in analog quantity of the Mitsubishi PLC function module is changed to current input
Mitsubishi FX5UCPU module has a built-in analog input as a voltage input (DC0-10V),
In this way, it can be converted into an analog current input (DC4 - 20m).
[Method used in current input (DC4 - 20mA)]
FX5UCPU module only supports voltage ...
|
|