The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

The new iQ-F motion module is a controller that can perform advanced motion control such as positioning, synchronization, cam, speed, torque, etc., with a computing cycle of 500μs, and can be connected to a high-function servo amplifier through CC-Link IE TSN, making a higher contribution to the miniaturization and high functionality of the equipment.

                               The Mitsubishi iQ-F series is compatible with CC-Link IE TSN motion modules

Excellent function:

It has a compatible function and can use the FX5-nSSC-S program;

The minimum operation period is 500μs (4-axis linear interpolation) to complete high-speed motion control;

By using a single controller on the same network, it is possible to build a system that includes long-distance I/O and PP mode servo amplifiers.

Servo amplifiers and long-distance I/O can be used to synchronize with external input signals with high accuracy.

The iQ-F motion module and MELSERVO-J5 form a total drive solution plan, which is advanced and convenient to upgrade. By detecting the vibration and collision changes of components, guessing the life of components, completing guess protection, preventing faulty downtime and reducing protection time, improving the working rate of equipment and ensuring high productivity and high-quality production. Together, they can be easily programmed, and high-performance servo amplifiers can be connected, and users can be considered to provide more efficient servo motor planning.

As a cost-effective network servo for CC-Link IE TSN communication, MELSERVO-JET can easily build a 4-axis to 256-axis servo system with a communication cycle of up to 125μs, providing a variety of tuning methods to support the same amplifier to control motors of different capacities. The deployment of MELSERVO-JET and iQ-F motion modules creates a cost-effective motion control plan with higher flexibility, connectivity, and protection, and will greatly shorten the programming and engineering implementation cycle, providing users with more suitable solutions.
More on that
Mitsubishi servo motor shaft failure causes and solutions Mitsubishi servo motor shaft failure causes and solutions

1. The cause of the failure (1) Unreasonable mechanical design leads to excessive radial load force; (2) The load side is stuck, or the moment of severe overload; (3) The motor and reducer are not centered when installed; 2. Fault cleaning ...

Mitsubishi PLC Step Instruction Instructions for use Mitsubishi PLC Step Instruction Instructions for use

1. Step Instruction (STL/RET) Step instruction is an instruction that is specially planned for sequential control. In the field of industrial control, many control processes can be completed by sequential control, and the use of step instructions to complete sequential control is not only convenient to complete, but also easy to read and modify. There are two in the FX2N ...

Mitsubishi servo system failure problem Mitsubishi servo system failure problem

The origin position is incorrect, and the encoder debugs/zeros the bit Replacement bearings, bearing groove wear, rotor cracking, shaft cracking Gear groove wear The magnet bursts steel, the magnet falls, gets stuck and doesn't move Encoder wear, code ...

Performance comparison of Mitsubishi servo motors Performance comparison of Mitsubishi servo motors

First, the control accuracy is different The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors, which are also some functions, have a smaller step angle after segmentation. ...

PLC is different from each output type PLC is different from each output type

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The biggest advantage is that it is suitable for high-frequency action, and the sound ...

How to deal with Mitsubishi PLC failures How to deal with Mitsubishi PLC failures

01. Base system problem In Mitsubishi PLC, there are binary, octal, decimal, 10, 2-10 (BCD), etc., we need to master the conversion of 2-8 base. 2-8, remember the binary number from the back, divide every 3 into a group, and each group is converted into octal respectively, such as 1 ...

Mitsubishi AnS series analog module bias and gain applications Mitsubishi AnS series analog module bias and gain applications

In today's industrial field, when using analog-to-digital conversion or digital-to-analog conversion, most of them do not only use the standard input characteristics of -10V-+10V, 0-20mA, but according to the practical voltage and current values to do the process requirements, then it is necessary to do the AD or DA module ...

PLC Processor Performance Test – Mitsubishi PLC Processor Performance Test – Mitsubishi

The processor performance test should be carried out in accordance with the requirements of the system manual, to ensure that the system has the function described in the manual, and is stable and reliable, including the system communication, backup battery and other special modules to view. Redundancy testing is necessary for systems with redundant equipment. i.e. the redundant design ...

The built-in analog quantity of the Mitsubishi PLC function module is changed to current input The built-in analog quantity of the Mitsubishi PLC function module is changed to current input

Mitsubishi FX5UCPU module has a built-in analog input as a voltage input (DC0-10V), In this way, it can be converted into an analog current input (DC4 - 20m). [Method used in current input (DC4 - 20mA)] FX5UCPU module only supports voltage ...

Mitsubishi PLC FX series position control unit Mitsubishi PLC FX series position control unit

The FX-20GM is a 2-axis positioning machine that can be operated independently. 1. Pulse output unit 1. Point-controlled pulse output unit F2-30GM 2. Pulse output module FX-1PG (for FX2 and FX2C) ...

Explanation of Mitsubishi pIc source type and drain type Explanation of Mitsubishi pIc source type and drain type

The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal. The general input points are ...

PLC troubleshooting method - Mitsubishi PLC troubleshooting method - Mitsubishi

1. If the PLC stops in the middle of some outputs where the output is excited, then look for the signal that caused the next operation (input, timer, line, drum manipulator, etc.). The programmer will show the ON/OFF status of that signal. ...

Malfunction caused by capacitance between PLC input lines – Mitsubishi Malfunction caused by capacitance between PLC input lines – Mitsubishi

There is a capacitance between the wires of the cable, and a qualified cable can limit this capacitance to a certain size. It is a qualified cable, when the cable length exceeds a certain length, the capacitance value between the lines will also exceed the required value, when the cable is used for PLC input, the capacitance between the lines will be ...

Mitsubishi Electric one-click adjustment user instruction mode tuning method Mitsubishi Electric one-click adjustment user instruction mode tuning method

1. Set PA08 to 0003 and set the gain adjustment form to; , the function is to prevent the failure of the active calculation of the inertia ratio, and the alarm C005 will be given. 2. Flip it over; menu; , set the speed/acceleration and deceleration/movement amount, according to the actual situation ...

Mitsubishi inverter E6 and E7 are faulty Mitsubishi inverter E6 and E7 are faulty

E6, E7 fault for the majority of users must not be unfamiliar, this is a more common Mitsubishi inverter typical problem, of course, the cause of damage is also multifaceted. IC 1302H02 is damaged, which is a piece of integrated drive ...

Anti-interference performance measures of Mitsubishi PLC system Anti-interference performance measures of Mitsubishi PLC system

1. Choose a power supply with excellent performance and press the disturbance introduced by the power grid In the PLC control system, the power supply occupies a very important position. The power grid disturbance series into the PLC control system is mainly through the power supply of the PLC system (such as CPU power supply, I/O power supply, etc.), the power supply of the transmitter and the power supply with P ...

What are the main factors of interference in Mitsubishi PLC system? What are the main factors of interference in Mitsubishi PLC system?

(1) Radiative dry disturbance from space The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...

Mitsubishi servo motor AL.50 alarm solution Mitsubishi servo motor AL.50 alarm solution

During the operation of the Mitsubishi servo motor, it may be possible to display an AL.50 alarm under certain circumstances (such as after a period of continuous operation), what is going on? And how to solve it? First of all, we need to know that the reason why the AL.50 alarm is presented is because the Mitsubishi servo ...

The impact of Mitsubishi inverters on the quality of the power grid The impact of Mitsubishi inverters on the quality of the power grid

In the case of impact loads such as electric welding machines, electric arc furnaces, rolling mills, etc., the voltage often flickers; In a workshop, when there are multiple Mitsubishi inverters and other capacitive rectifier loads working, the harmonics that occur are very serious pollution about the quality of the power grid, and there is also considerable damage to the equipment itself.

The difference between a Mitsubishi servo motor and a stepper motor The difference between a Mitsubishi servo motor and a stepper motor

First, the control accuracy is different The step angle of the two-phase hybrid stepper motor is generally 1.8° and 0.9°, and the step angle of the five-phase hybrid stepper motor is generally 0.72° and 0.36°. There are also some high-performance stepper motors that have a smaller step angle after being subdivided. Communicate the control of servo motor ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top